Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.867
Filtrar
1.
Rev Assoc Med Bras (1992) ; 70(4): e20230998, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38716936

RESUMO

OBJECTIVE: The use of cardiac implantable electronic devices has increased in recent years. It has also brought some issues. Among these, the complications of cardiac implantable electronic devices infection and pocket hematoma are difficult to manage. It can be fatal with the contribution of patient-related risk factors. In this study, we aimed to find mortality rates in patients who developed cardiac implantable electronic devices infection and pocket hematoma over 5 years. We also investigated the risk factors affecting mortality in patients with cardiac implantable electronic devices. METHODS: A total of 288 cardiac implantable electronic devices patients were evaluated. Demographic details, history, and clinical data of all patients were recorded. Cardiac implantable electronic devices infection was defined according to the modified Duke criteria. The national registry was used to ascertain the mortality status of the patients. The patients were divided into two groups (exitus and survival groups). In addition, the pocket hematoma was defined as significant bleeding at the pocket site after cardiac implantable electronic devices placement. RESULTS: The cardiac implantable electronic devices infection was similar in both groups (p=0.919), and the pocket hematoma was higher in the exitus group (p=0.019). The exitus group had higher usage of P2Y12 inhibitors (p≤0.001) and novel oral anticoagulants (p=0.031). The Cox regression analysis, including mortality-related factors, revealed that renal failure is the most significant risk factor for mortality. Renal failure was linked to a 2.78-fold higher risk of death. CONCLUSION: No correlation was observed between cardiac implantable electronic devices infection and mortality, whereas pocket hematoma was associated with mortality. Furthermore, renal failure was the cause of the highest mortality rate in patients with cardiac implantable electronic devices.


Assuntos
Desfibriladores Implantáveis , Hematoma , Marca-Passo Artificial , Humanos , Feminino , Masculino , Desfibriladores Implantáveis/efeitos adversos , Fatores de Risco , Idoso , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Hematoma/etiologia , Hematoma/mortalidade , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/etiologia , Estudos Retrospectivos , Fatores de Tempo , Idoso de 80 Anos ou mais
2.
Rev. esp. cardiol. (Ed. impr.) ; 77(5): 362-369, mayo 2024. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-JHG-67

RESUMO

Introducción y objetivos: La experiencia con el desfibrilador automático implantable subcutáneo (DAI-SC) en pacientes pediátricos aún es reducida. El objetivo de este estudio es determinar la incidencia de complicaciones en pacientes pediátricos de nuestro centro en función del tipo de DAI y del tamaño del paciente.MétodosSe incluyó a pacientes menores de 18 años que recibieron un DAI-SC desde 2016 y pacientes contemporáneos (desde 2014) que recibieron un DAI transvenoso (DAI-TV). El evento principal fue el combinado de complicaciones y descargas inapropiadas.ResultadosSe implantó un DAI-SC a 26 pacientes (edad, 14 [intervalo, 5-17] años; índice de masa corporal [IMC], 20,2). De ellos, 23 (88%) fueron implantes intermusculares y el resto, en subserrato, 24 (92%) con 2 incisiones. Se programaron 2 zonas en todos los pacientes: condicional a 230 (220-230) lpm y de choque a 250 lpm. El grupo de DAI-TV incluyó a 19 pacientes (edad, 11 [5-16] años; IMC, 19,2; el 79% monocamerales). La supervivencia libre del evento principal a 5 años fue el 80% de los pacientes con DAI-SC y el 63% del grupo con DAI-TV (p=0,54); la de descargas inapropiadas fue similar (el 85 frente al 89%; p=0,86), mientras que la de complicaciones fue mayor en el grupo de DAI-SC (el 96 frente al 57%; cloglog p=0.016). En el grupo de DAI-SC no hubo fallo de la terapia ni mayores complicaciones con un IMC ≤ 20.ConclusionesCon las técnicas de implante y programación actuales, el DAI-SC es eficaz y seguro en pacientes pediátricos, con similares descargas inapropiadas y menos complicaciones a corto y medio plazo que el DAI-TV. (AU)


Introduction and objectives: There is limited evidence regarding the use of subcutaneous implantable cardioverter-defibrillators (S-ICD) in pediatric patients. The aim of this study was to determine the incidence of complications in these patients at our center, according to the type of ICD and patient size.MethodsWe included all patients aged<18 years who received an S-ICD since 2016 at our center. As a control group, we also included contemporary patients (since 2014) who received a transvenous ICD (TV-ICD). The primary endpoint was a composite of complications and inappropriate shocks.ResultsA total of 26 patients received an S-ICD (median age, 14 [5-17] years; body mass index [BMI], 20.2 kg/m2). Implantation was intermuscular in 23 patients (88%) and subserratus in the remainder. Two incisions were used in 24 patients (92%). In all patients, 2 zones were programmed: a conditional zone set at 230 (220-230) bpm, and a shock zone set at 250 bpm. Nineteen patients received a TV-ICD (median age, 11 [range, 5-16] years; BMI, 19.2 kg/m2, 79% single-chamber). Survival free from the primary endpoint at 5 years was 80% in the S-ICD group and 63% in the TV-ICD group (P=.54). Survival free from inappropriate shocks was similar (85% vs 89%, P=.86), while survival free from complications was higher in the S-ICD group (96% vs 57%, cloglogP=.016). There were no therapy failures in the S-ICD group, and no increased complication rates were observed in patients with BMI ≤ 20 kg/m2.ConclusionsWith contemporary implantation techniques and programming, S-ICD is a safe and effective therapy in pediatric patients. The number of inappropriate shocks is similar to TV-ICD, with fewer short- and mid-term complications. (AU)


Assuntos
Humanos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Seguimentos , Incidência
4.
J Am Heart Assoc ; 13(8): e032033, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38591264

RESUMO

BACKGROUND: Chronic total coronary occlusions (CTO) substantially increase the risk for sudden cardiac death. Among patients with chronic ischemic heart disease at risk for sudden cardiac death, an implantable cardioverter defibrillator (ICD) is the favored therapy for primary prevention of sudden cardiac death. This study sought to investigate the impact of CTOs on the risk for appropriate ICD shocks and mortality within a nationwide prospective cohort. METHODS AND RESULTS: This is a subanalysis of the nationwide Dutch-Outcome in ICD Therapy (DO-IT) registry of primary prevention ICD recipients in The Netherlands between September 2014 and June 2016 (n=1442). We identified patients with chronic ischemic heart disease (n=663) and assessed available coronary angiograms for CTO presence (n=415). Patients with revascularized CTOs were excluded (n=79). The primary end point was the composite of all-cause mortality and appropriate ICD shocks. Clinical follow-up was conducted for at least 2 years. A total of 336 patients were included, with an average age of 67±9 years, and 20.5% was female (n=69). An unrevascularized CTO was identified in 110 patients (32.7%). During a median follow-up period of 27 months (interquartile range, 24-32), the primary end point occurred in 21.1% of patients with CTO (n=23) compared with 11.9% in patients without CTO (n=27; P=0.034). Corrected for baseline characteristics including left ventricular ejection fraction, and the presence of a CTO was an independent predictor for the primary end point (hazard ratio, 1.82 [95% CI, 1.03-3.22]; P=0.038). CONCLUSIONS: Within this nationwide prospective registry of primary prevention ICD recipients, the presence of an unrevascularized CTO was an independent predictor for the composite outcome of all-cause mortality and appropriate ICD shocks.


Assuntos
Oclusão Coronária , Desfibriladores Implantáveis , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Oclusão Coronária/complicações , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Arritmias Cardíacas , Desfibriladores Implantáveis/efeitos adversos , Volume Sistólico , Incidência , Função Ventricular Esquerda , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Sistema de Registros , Fatores de Risco
5.
J Am Coll Cardiol ; 83(14): 1326-1337, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38569763

RESUMO

Cardiac implantable electronic device-related infective endocarditis (CIED-IE) encompasses a range of clinical syndromes, including valvular, device lead, and bloodstream infections. However, accurately diagnosing CIED-IE remains challenging owing in part to diverse clinical presentations, lack of standardized definition, and variations in guideline recommendations. Furthermore, current diagnostic modalities, such as transesophageal echocardiography and [18F]-fluorodeoxyglucose positron emission tomography-computed tomography have limited sensitivity and specificity, further contributing to diagnostic uncertainty. This can potentially result in complications and unnecessary costs associated with inappropriate device extraction. Six hypothetical clinical cases that exemplify the diverse manifestations of CIED-IE are addressed herein. Through these cases, we highlight the importance of optimizing diagnostic accuracy and stewardship, understanding different pathogen-specific risks for bloodstream infections, guiding appropriate device extraction, and preventing CIED-IE, all while addressing key knowledge gaps. This review both informs clinicians and underscores crucial areas for future investigation, thereby shedding light on this complex and challenging syndrome.


Assuntos
Desfibriladores Implantáveis , Endocardite Bacteriana , Endocardite , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Sepse , Humanos , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Endocardite/diagnóstico , Endocardite/etiologia , Endocardite Bacteriana/complicações
6.
J Cardiovasc Electrophysiol ; 35(5): 1017-1025, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501386

RESUMO

Tricuspid regurgitation (TR) secondary to cardiac implantable electronic devices (CIEDs) has been well documented and is associated with worse cardiovascular outcomes. A variety of mechanisms have been proposed including lead-induced mechanical disruption of the tricuspid valvular or subvalvular apparatus and pacing-induced electrical dyssynchrony. Patient characteristics such as age, sex, baseline atrial fibrillation, and pre-existing TR have not been consistent predictors of CIED-induced TR. While two-dimensional echocardiography is helpful in assessing the severity of TR, three-dimensional echocardiography has significantly improved accuracy in identifying the etiology of TR and whether lead position contributes to TR. Three-dimensional echocardiography may therefore play a future role in optimizing lead positioning during implant to reduce the risk of CIED-induced TR. Optimal lead management strategies in addition to percutaneous interventions and surgery in alleviating TR are very important.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Fatores de Risco , Resultado do Tratamento , Ecocardiografia Tridimensional
8.
J Am Heart Assoc ; 13(6): e032047, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38456399

RESUMO

BACKGROUND: Current guidelines recommend placing an implantable cardiac defibrillator for patients with cardiac sarcoidosis and a severely impaired left ventricular ejection fraction (LVEF) of ≤35%. In this study, we determined the association between mild or moderate LVEF impairment and fatal ventricular arrhythmic event (FVAE). METHODS AND RESULTS: We retrospectively analyzed 401 patients with cardiac sarcoidosis without sustained ventricular arrhythmia at diagnosis. The primary end point was an FVAE, defined as the combined endpoint of documented ventricular tachycardia or ventricular fibrillation and sudden cardiac death. Two cutoff points for LVEF were used: a sex-specific lower threshold of normal range of LVEF (52% for men and 54% for women) and an LVEF of 35%, which is used in the current guidelines. During a median follow-up of 3.2 years, 58 FVAEs were observed, and the 5- and 10-year estimated incidences of FVAEs were 16.8% and 23.0%, respectively. All patients were classified into 3 groups according to LVEF: impaired LVEF group, mild to moderate impairment of LVEF group, and maintained LVEF group. Multivariable competing risk analysis showed that both the impaired LVEF group (hazard ratio [HR], 3.24 [95% CI, 1.49-7.04]) and the mild to moderate impairment of LVEF group (HR, 2.16 [95% CI, 1.04-4.46]) were associated with a higher incidence of FVAEs than the maintained LVEF group after adjustment for covariates. CONCLUSIONS: Patients with cardiac sarcoidosis are at a high risk of FVAEs, regardless of documented ventricular arrhythmia at the time of diagnosis. In patients with cardiac sarcoidosis, mild to moderate impairment of LVEF is associated with FVAEs.


Assuntos
Desfibriladores Implantáveis , Miocardite , Sarcoidose , Masculino , Humanos , Feminino , Função Ventricular Esquerda , Volume Sistólico , Estudos Retrospectivos , Sarcoidose/complicações , Sarcoidose/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/complicações , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Miocardite/complicações
9.
Med J Aust ; 220(5): 249-257, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38493353

RESUMO

OBJECTIVES: To determine the annual numbers of first ICD insertions in New South Wales during 2005-2020; to examine health outcomes for people who first received ICDs during this period. STUDY DESIGN: Retrospective cohort study; analysis of linked administrative health data. SETTING, PARTICIPANTS: All first insertions of ICDs in NSW, 2005-2020. MAIN OUTCOME MEASURES: Annual numbers of first ICD insertions, and of emergency department presentations and hospital re-admissions 30 days, 90 days, 365 days after first ICD insertions; all-cause and disease-specific mortality (to ten years after ICD insertion). RESULTS: During 2005-2020, ICDs were first inserted into 16 867 people (18.5 per 100 000 population); their mean age was 65.7 years (standard deviation, 13.5 years; 7376 aged 70 years or older, 43.7%), 13 214 were men (78.3%). The annual number of insertions increased from 791 in 2005 to 1256 in 2016; the first ICD insertion rate increased from 15.5 in 2005 to 18.9 per 100 000 population in 2010, after which the rate was stable until 2019 (19.8 per 100 000 population). Of the 16 778 people discharged alive from hospital after first ICD insertions, 54.4% presented to emergency departments within twelve months, including 1236 with cardiac arrhythmias (7.4%) and 434 with device-related problems (2.6%); 56% were re-admitted to hospital, including 1944 with cardiac arrhythmias (11.5%) and 2045 with device-related problems (12.1%). A total of 5624 people who received first ICDs during 2005-2020 (33.3%) died during follow-up (6.7 deaths per 100 person-years); the survival rate was 94.4% at one year, 76.5% at five years, and 54.2% at ten years. CONCLUSIONS: The annual number of new ICDs inserted in NSW has increased since 2005. A substantial proportion of recipients experience device-related problems that require re-admission to hospital. The potential harms of ICD insertion should be considered when assessing the likelihood of preventing fatal ventricular arrhythmia.


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Masculino , Humanos , Idoso , Feminino , Estudos Retrospectivos , New South Wales/epidemiologia , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Arritmias Cardíacas/complicações , Desfibriladores Implantáveis/efeitos adversos , Coração , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia
10.
Turk Kardiyol Dern Ars ; 52(2): 81-87, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38465533

RESUMO

OBJECTIVE: Atrial High Rate Episodes (AHRE) are subclinical atrial tachyarrhythmias detectable by cardiac implantable electronic devices (CIEDs). AHREs have been associated with an increased risk of developing atrial fibrillation (AF), thromboembolism, cardiovascular and cerebrovascular events, and mortality. Although recent studies have assessed the value of oxidative stress markers in patients with AF, the relationships between AHRE and oxidative stress markers, including nitric oxide, has not yet been elucidated. This study aims to investigate the relationship between these markers and AHRE. METHOD: This prospective, cross-sectional study comprised 180 patients with CIEDs. The study population was divided into two groups based on the presence (n = 78) and absense (n = 102) of AHRE to analyze its association with biomarkers. RESULTS: The AHRE (+) group was significantly older, had a higher prevalence of hypertension, higher NT-proBNP (508.8 ± 249 pg/mL vs. 415.3 ± 292.1; P = 0.037), MDA levels (20.9 ± 4.1 µmol/L vs. 19.1 ± 3.1 µmol/L; P = 0.006), and iNOS activity (1,935.9 ± 326.1 pg/mL vs. 1,677.4 ± 363.2 pg/mL; P < 0.001). Logistic regression analysis identified age, hypertension, MDA (odds ratio [OR]: 1.131, 95%CI: 1.009 - 1.268, P = 0.035), inducible nitric oxide synthase (iNOS) activity (OR = 1.002, 95% CI = 1.001 - 1.003, P < 0.001), and endothelial nitric oxide synthase (eNOS) activity (OR = 0.990, 95% CI = 0.986 - 0.984, P < 0.001) as independent predictors of AHRE. CONCLUSION: The study findings indicated that plasma levels of NT-proBNP, MDA, nitric oxide, and the expression of iNOS and eNOS were significantly associated with AHRE. Moreover, elevated plasma MDA concentrations, increased iNOS activity, and decreased eNOS activity were identified as independent predictors of AHRE.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Hipertensão , Humanos , Óxido Nítrico , Desfibriladores Implantáveis/efeitos adversos , Estudos Prospectivos , Estudos Transversais , Fibrilação Atrial/complicações , Hipertensão/complicações , Fatores de Risco
11.
Kardiologiia ; 64(2): 27-33, 2024 Feb 29.
Artigo em Russo | MEDLINE | ID: mdl-38462801

RESUMO

AIM: To study the predictive capabilities of the MADIT-ICD Benefit Score calculator in assessing the benefit of implantable cardioverter defibrillator (ICD) placement for the primary prevention of sudden cardiac death (SCD). MATERIAL AND METHODS: This study included 388 patients with NYHA II-IV functional class chronic heart failure (CHF) with a left ventricular ejection fraction (LVEF) ≤35 % who underwent ICD placement for the primary prevention of SCD. Patients were followed up for two years to record the endpoints of first-time paroxysmal sustained ventricular tachyarrhythmia (VT) or non-arrhythmic death. RESULTS: According to the results of calculation with the MADIT-ICD Benefit Score calculator, 276 (71 %) patients had a high risk of VT (score ≥7) and 150 (39 %) had a high risk of non-arrhythmic death (score ≥3). 336 (94%) patients would benefit from an ICD: 148 (38 %) with a high level of probability and 218 (56 %) with a medium level of probability. According to the incidence of endpoints, VT episodes predominated in the low-ICD benefit group (36%), while the high-ICD benefit group had a relatively high incidence of non-arrhythmic death (12%). CONCLUSION: The results obtained for a cohort of Russian patients with CHF and reduced LVEF indicated that the use of the MADIT-ICD Benefit Score in routine clinical practice does not improve the stratification of SCD risk compared to the traditional approach to selecting patients with CHF for ICD based on the LVEF value.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Volume Sistólico , Função Ventricular Esquerda , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Desfibriladores/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Fatores de Risco
12.
Pacing Clin Electrophysiol ; 47(4): 496-502, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38462721

RESUMO

BACKGROUND: Inappropriate shock (IAS) caused by subcutaneous air entrapment (AE) in an early period after subcutaneous implantable cardioverter defibrillator (S-ICD) implantation has been reported, however, no detailed data on air volume are available. We evaluated the subcutaneous air volume after implantation and its absorption rate one week after implantation. METHODS: Patients who underwent S-ICD implantation in our hospital received chest CT scans immediately after implantation and followed up 1 week later. The total subcutaneous air volume, air around the generator, the distal electrode, and the proximal electrode within 3 cm were calculated using a three-dimensional workstation. Fat areas at the level of the lower edge of the generator were also analyzed. RESULT: Fifteen patients received CT immediately after implantation. The mean age was 45.6 ± 17.9 (66.7% of men), and the mean body mass index was 24.3 ± 3.3. The three-incision technique was applied in seven patients and two-incision technique was in the latter eight patients. The mean total subcutaneous air volume was 18.54 ± 7.50 mL. Air volume around the generator, the distal electrode, and the proximal electrode were 11.05 ± 5.12, 0.72 ± 0.72, and 0.88 ± 0.87 mL, respectively. Twelve patients received a follow-up CT 1 week later. The mean total subcutaneous air was 0.25 ± 0.45 mL, showing a 98.7% absorption rate. CONCLUSION: Although subcutaneous air was observed in all patients after S-ICD implantation, most of the air was absorbed within 1 week, suggesting a low occurrence of AE-related IAS after a week postoperation.


Assuntos
Desfibriladores Implantáveis , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Tomografia Computadorizada por Raios X , Tomografia , Resultado do Tratamento
13.
Eur Heart J ; 45(14): 1269-1277, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38546408

RESUMO

BACKGROUND AND AIMS: Bloodstream infection (BSI) of any cause may lead to device infection in cardiac implantable electronic device (CIED) patients. Aiming for a better understanding of the diagnostic approach, treatment, and outcome, patients with an implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy and defibrillator (CRT-D) hospitalized with BSI were investigated. METHODS: This is a single-centre, retrospective, cohort analysis including consecutive ICD/CRT-D patients implanted between 2012 and 2021. These patients were screened against a list of all hospitalized patients having positive blood cultures consistent with diagnosed infection in any department of a local public hospital. RESULTS: The total cohort consisted of 515 patients. Over a median follow-up of 59 months (interquartile range 31-87 months), there were 47 BSI episodes in 36 patients. The majority of patients with BSI (92%) was admitted to non-cardiology units, and in 25 episodes (53%), no cardiac imaging was performed. Nearly all patients (85%) were treated with short-term antibiotics, whereas chronic antibiotic suppression therapy (n = 4) and system extraction (n = 3) were less frequent. Patients with BSI had a nearly seven-fold higher rate (hazard ratio 6.7, 95% confidence interval 3.9-11.2; P < .001) of all-cause mortality. CONCLUSIONS: Diagnostic workup of defibrillator patients with BSI admitted to a non-cardiology unit is often insufficient to characterize lead-related endocarditis. The high mortality rate in these patients with BSI may relate to underdiagnosis and consequently late/absence of system removal. Efforts to increase an interdisciplinary approach and greater use of cardiac imaging are necessary for timely diagnosis and adequate treatment.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Sepse , Humanos , Estudos Retrospectivos , Desfibriladores Implantáveis/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Antibacterianos/uso terapêutico , Sepse/etiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Resultado do Tratamento
16.
Heart Lung Circ ; 33(3): 368-375, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38336540

RESUMO

BACKGROUND: Alcoholic cardiomyopathy (ACM) is a form of dilated cardiomyopathy (DCM) occurring secondary to long-standing heavy alcohol use and is associated with poor outcomes, but the cause-specific risks are insufficiently understood. METHOD: Between 1997 and 2018, we identified all patients with a first diagnosis of ACM or DCM. The cumulative incidence of different causes of hospitalisation and mortality in the two groups was calculated using the Fine-Gray and Kaplan-Meier methods. RESULTS: A Total of 1,237 patients with ACM (mean age 56.3±10.1 years, 89% men) and 17,211 individuals with DCM (mean age 63.6±13.8 years, 71% men) were identified. Diabetes (10% vs 15%), hypertension (22% vs 31%), and stroke (8% vs 10%) were less common in ACM than DCM, whereas obstructive lung disease (15% vs 12%) and liver disease (17% vs 2%) were more prevalent (p<0.05). Cumulative 5-year mortality was 49% in ACM vs 33% in DCM, p<0.0001, multivariable adjusted hazards ratio 2.11 (95% confidence interval 1.97-2.26). The distribution of causes of death was similar in ACM and DCM, with the predominance of cardiovascular causes in both groups (42% in ACM vs 44% in DCM). 5-year cumulative incidence of heart failure hospitalisations (48% vs 54%) and any somatic cause (59% vs 65%) were also similar in ACM vs DCM. At 1 year, the use of beta blockers (55% vs 80%) and implantable cardioverter defibrillators (3% vs 14%) were significantly less often used in ACM vs DCM. CONCLUSIONS: Patients with ACM had similar cardiovascular risks and hospitalisation patterns as other forms of DCM, but lower use of guideline-directed cardiovascular therapies and greater mortality.


Assuntos
Cardiomiopatia Alcoólica , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Insuficiência Cardíaca , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/epidemiologia , Cardiomiopatia Dilatada/terapia , Cardiomiopatia Alcoólica/diagnóstico , Cardiomiopatia Alcoólica/epidemiologia , Cardiomiopatia Alcoólica/terapia , Desfibriladores Implantáveis/efeitos adversos , Incidência
17.
J Cardiovasc Electrophysiol ; 35(4): 675-684, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38323491

RESUMO

INTRODUCTION: Despite advancements in implantable cardioverter-defibrillator (ICD) technology, sudden cardiac death (SCD) remains a persistent public health concern. Chagas disease (ChD), prevalent in Brazil, is associated with increased ventricular tachycardia (VT) and ventricular fibrillation (VF) events and SCD compared to other cardiomyopathies. METHODS: This retrospective observational study included patients who received ICDs between October 2007 and December 2018. The study aims to assess whether mortality and VT/VF events decreased in patients who received ICDs during different time periods (2007-2010, 2011-2014, and 2015-2018). Additionally, it seeks to compare the prognosis of ChD patients with non-ChD patients. Time periods were chosen based on the establishment of the Arrhythmia Service in 2011. The primary outcome was overall mortality, assessed across the entire sample and the three periods. Secondary outcomes included VT/VF events and the combined outcome of death or VT/VF. RESULTS: Of the 885 patients included, 31% had ChD. Among them, 28% died, 14% had VT/VF events, and 37% experienced death and/or VT/VF. Analysis revealed that period 3 (2015-2018) was associated with better death-free survival (p = .007). ChD was the only variable associated with a higher rate of VT/VF events (p < .001) and the combined outcome (p = .009). CONCLUSION: Mortality and combined outcome rates decreased gradually for ICD patients during the periods 2011-2014 and 2015-2018 compared to the initial period (2007-2010). ChD was associated with higher VT/VF events in ICD patients, only in the first two periods.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Cardiomiopatias/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , América Latina , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiologia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia , Fibrilação Ventricular/etiologia , Estudos Retrospectivos
18.
J Cardiovasc Electrophysiol ; 35(4): 794-801, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38384108

RESUMO

INTRODUCTION: Several implantable cardioverter defibrillators (ICD) programming strategies are applied to minimize ICD therapy, especially unnecessary therapies from supraventricular arrhythmias (SVA). However, it remains unknown whether these optimal programming recommendations only benefit those with SVAs or have any detrimental effects from delayed therapy on those without SVAs. This study aims to assess the impact of SVA on the outcomes of ICD programming based on 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement and 2019 focused update on optimal ICD programming and testing guidelines. METHODS: Consecutive patients who underwent ICD insertion for primary prevention were classified into four groups based on SVA status and ICD programming: (1) guideline-concordant group (GC) with SVA, (2) GC without SVA, (3) nonguideline concordant group (NGC) with SVA, and (4) NGC without SVA. Cox proportional hazard models were analyzed for freedom from ICD therapies, shock, and mortality. RESULTS: Seven hundred and seventy-two patients (median age, 64 years) were enrolled. ICD therapies were the most frequent in NGC with SVA (24.0%), followed by NGC without SVA (19.9%), GC without SVA (11.6%), and GC with SVA (8.1%). Guideline concordant programming was associated with 68% ICD therapy reduction (HR 0.32, p = .007) and 67% ICD shock reduction (HR 0.33, p = .030) in SVA patients and 44% ICD therapy reduction in those without SVA (HR 0.56, p = .030). CONCLUSION: Programming ICDs in primary prevention patients based on current guidelines reduces therapy burden without increasing mortality in both SVA and non-SVA patients. A greater magnitude of reduced ICD therapy was found in those with supraventricular arrhythmias.


Assuntos
Desfibriladores Implantáveis , Humanos , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Arritmias Cardíacas , Morte Súbita Cardíaca/prevenção & controle
19.
J Cardiovasc Electrophysiol ; 35(4): 785-793, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38383981

RESUMO

INTRODUCTION: Wearable cardioverter defibrillator (WCD) is utilized in patients with assumed but not yet confirmed risk for sudden cardiac death (SCD). Many of these patients also present with atrial fibrillation (AF). However, the rate of WCD-detected ventricular or atrial arrhythmia events in this specific high-risk cohort is not well understood. METHODS: In WEARIT-II, the cumulative probability of any sustained or nonsustained VT/VF (WCD-treated and nontreated), and atrial/supraventricular arrhythmias during WCD use was assessed using the Kaplan-Meier method by prior AF, with comparisons by the log-rank test. The incidence of ventricular and atrial arrhythmia events were expressed as events per 100 patient-years, and were analyzed by prior AF using negative binomial regression. RESULTS: WEARIT-II enrolled 2000 patients, 557 (28%) of whom had AF before enrollment. Cumulative probability of any sustained or nonsustained WCD-detected VT/VF during WCD use was significantly higher among patients with a history of AF than without AF (6% vs. 3%, p = .001). Similarly, the recurrent rate of any sustained or nonsustained VT/VF was significantly higher in patients with prior AF versus no prior AF (131.5 events per 100 patient-years vs. 22.7 events per 100 patient-years, p = .001). Patients with prior AF also had a significantly higher burden of any WCD-detected atrial arrhythmias/SVT/inappropriate arrhythmias therapy (183.2 events per 100 patient-years vs. 74.8 events per 100 patient-years, p < .001). CONCLUSION: Our results demonstrate that patients with a history of AF wearing the WCD for risk assessment have a higher incidence of ventricular arrhythmias that may facilitate the decision making for ICD implantation.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Cardioversão Elétrica/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Medição de Risco , Sistema de Registros , Desfibriladores Implantáveis/efeitos adversos
20.
Curr Probl Cardiol ; 49(5): 102483, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38401822

RESUMO

BACKGROUND: Implantable cardioverter defibrillator (ICD) use in cardiac sarcoidosis (CS) to prevent sudden cardiac death (SCD) is a potentially life-saving intervention. However, the factors that determine outcome in this cohort remains largely unknown. This review analyses CS patients with an ICD and highlights determinants of poor outcome. OUTCOMES: Analysis of studies which used the 2014 HRS Consensus, 2017 AHA/ACC/HRS Guideline and 2022 ESC Guidelines showed that those with class I recommendations have higher incidences of ventricular arrhythmia (VA) than those with class II recommendations. Additionally, even those with normal left ventricular ejection fraction (LVEF) and CS are at high risk of VA and SCD. SUMMARY: Compounding research emphasises the importance of cardiac imaging in those with sarcoidosis, with evidence to suggest a possible need for revision of the guidelines. Other variables such as demographics and ventricular characteristics may prove useful in predicting those to benefit most from ICD insertion.


Assuntos
Desfibriladores Implantáveis , Sarcoidose , Humanos , Volume Sistólico , Desfibriladores Implantáveis/efeitos adversos , Função Ventricular Esquerda , Sarcoidose/complicações , Sarcoidose/diagnóstico , Sarcoidose/terapia , Arritmias Cardíacas , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...