Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.290
Filtrar
1.
Medicine (Baltimore) ; 103(20): e38194, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758875

RESUMO

This study aimed to compare the postimplantation clinical outcomes of 2 types of posterior chamber phakic intraocular lenses (IOLs): Visian™ implantable collamer lenses (ICL; EVO+ V5; Staar Surgical, Monrovia, CA) and an implantable phakic contact lens (IPCL) (IPCL V2.0, Care Group Sight Solution, India) to correct high myopia and myopic astigmatism. This retrospective study included patients who had undergone phakic IOL implantation performed by a single surgeon between March 2021 and March 2022. Preoperative assessments included slit-lamp examination, fundus examination, spherical equivalent, uncorrected distant visual acuity (UDVA), corrected distant visual acuity (CDVA), specular microscope parameters, and optical quality analysis system parameters. Postoperative assessments after 1 year included slit-lamp examination to detect adverse effects and spherical equivalent, UDVA, CDVA, specular microscope, optical quality analysis system, and anterior-segment optical coherence tomography. Eighty eyes from 42 patients (47 eyes from 24 patients in the ICL group and 33 eyes from 18 patients in the IPCL group) were included. No statistically significant differences were observed between the 2 groups regarding preoperative parameters. At 1-year postoperatively, the mean UDVA in the ICL and IPCL groups was 0.019 ±â€…0.040 logMAR and 0.019 ±â€…0.041 logMAR, respectively. The mean CDVA was 0.001 ±â€…0.008 logMAR and 0.001 ±â€…0.007 logMAR in the ICL and IPCL groups, respectively, showing no statistically significant differences. The postoperative parameters did not differ significantly between the 2 groups. The visual acuity and refractive results of both groups were excellent, and both groups exhibited similar efficacy and safety profiles.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares Fácicas , Acuidade Visual , Humanos , Masculino , Feminino , Estudos Retrospectivos , Adulto , Implante de Lente Intraocular/métodos , Implante de Lente Intraocular/efeitos adversos , Adulto Jovem , Astigmatismo/cirurgia , Miopia/cirurgia , Resultado do Tratamento
2.
Vestn Oftalmol ; 140(2): 34-39, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742496

RESUMO

PURPOSE: This study evaluates the accuracy of modern intraocular lens (IOL) calculation formulas using axial length (AL) data obtained by ultrasound biometry (UBM) compared to the third-generation SRK/T calculator. MATERIAL AND METHODS: The study included 230 patients (267 eyes) with severe lens opacities that prevented optical biometry, who underwent phacoemulsification (PE) with IOL implantation. IOL power calculation according to the SRK/T formula was based on AL and anterior chamber depth obtained by UBM (Tomey Biometer Al-100) and keratometry on the Topcon KR 8800 autorefractometer. To adapt AL for new generation calculators - Barrett Universal II (BUII), Hill RBF ver. 3.0 (RBF), Kane and Ladas Super Formula (LSF) - the retinal thickness (0.20 mm) was added to the axial length determined by UBM, and then the optical power of the artificial lens was calculated. The mean error and its modulus value were used as criteria for the accuracy of IOL calculation. RESULTS: A significant difference (p=0.008) in the mean IOL calculation error was found between the formulas. Pairwise analysis revealed differences between SRK/T (-0.32±0.58 D) and other formulas - BUII (-0.16±0.52 D; p=0.014), RBF (-0.17±0.51 D; p=0.024), Kane (-0.17±0.52 D; p=0.029), but not with the LSF calculator (-0.19±0.53 D; p=0.071). No significant differences between the formulas were found in terms of mean error modulus (p=0.238). New generation calculators showed a more frequent success in hitting target refraction (within ±1.00 D in more than 95% of cases) than the SRK/T formula (86%). CONCLUSION: The proposed method of adding 0.20 mm to the AL determined by UBM allows using this parameter in modern IOL calculation formulas and improving the refractive results of PE, especially in eyes with non-standard anterior segment structure.


Assuntos
Biometria , Lentes Intraoculares , Facoemulsificação , Refração Ocular , Humanos , Biometria/métodos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Refração Ocular/fisiologia , Facoemulsificação/métodos , Comprimento Axial do Olho/diagnóstico por imagem , Implante de Lente Intraocular/métodos , Catarata/fisiopatologia , Catarata/diagnóstico , Óptica e Fotônica/métodos , Microscopia Acústica/métodos
3.
Vestn Oftalmol ; 140(2): 40-46, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742497

RESUMO

Extended depth of focus (EDOF) intraocular lenses (IOLs) are the latest IOL designs. In recent years, several models of EDOF IOLs have become available in Russia, two of which (Tecnis Symfony and Acrysof IQ Vivity) are implanted in our clinic. Comparative studies devoted to the results of implantation of the new EDOF IOLs are rare in the available literature. PURPOSE: This article compares the outcomes of implantation of two EDOF IOLs in patients with presbyopia and/or cataract. MATERIAL AND METHODS: The prospective study included 60 patients (81 eyes) after implantation of EDOF IOL Tecnis Symfony (32 patients, 45 eyes; group 1) or EDOF IOL AcrySof IQ Vivity (28 patients, 36 eyes; group 2). The mean follow-up period was 3.9±1.3 months. RESULTS: All groups showed a significant (p<0.05) increase in uncorrected near visual acuity (UCNVA), intermediate visual acuity (UCIVA), and distance visual acuity (UCDVA) at the maximum follow-up time compared to preoperative values. In group 1, the best corrected near visual acuity (BCNVA) increased from 0.61±0.10 to 0.82±0.16 at the maximum follow-up time, and in group 2 - from 0.58±0.08 to 0.67±0.12 (p>0.05). Both groups showed a significant increase in best corrected intermediate and distance visual acuity (BCIVA and BCDVA) at the maximum follow-up time. The increase in the indicator compared to the preoperative period was not significant in both groups (p>0.05). The frequency of side optical phenomena was low in both groups. No significant differences were found between the groups (p>0.05). CONCLUSION: This study presents a comparative analysis of the results of implantation of two different EDOF IOLs. Both lenses were comparable in most of the studied parameters, including providing good distance and intermediate vision, functional near vision, as well as a low frequency of side optical phenomena. In all cases the patients were satisfied with the results of the surgical intervention.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Presbiopia , Acuidade Visual , Humanos , Masculino , Feminino , Implante de Lente Intraocular/métodos , Pessoa de Meia-Idade , Presbiopia/cirurgia , Presbiopia/fisiopatologia , Desenho de Prótese , Estudos Prospectivos , Idoso , Resultado do Tratamento , Catarata/fisiopatologia , Catarata/diagnóstico , Refração Ocular/fisiologia , Percepção de Profundidade/fisiologia , Federação Russa
4.
BMC Ophthalmol ; 24(1): 154, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594683

RESUMO

BACKGROUND: Intraocular lens (IOL) fixation is performed after intraoperative anterior or total vitrectomy. This study aimed to compare the intraoperative and postoperative complications of these two techniques. METHODS: This retrospective study included 235 eyes that underwent intrascleral fixation surgery at our hospital between July 2014 and January 2021. The eyes were classified into the anterior vitrectomy group (A-vit group; 134 eyes) and the pars plana vitrectomy group (PPV group; 101 eyes). The age, preoperative and postoperative best-corrected visual acuity, observation period, preoperative and postoperative intraocular pressure, and the incidence of intraoperative and postoperative complications were assessed. RESULTS: Intrascleral fixation was performed more frequently in the PPV group, and a significant difference was observed between the eyes with a history of vitrectomy and eyes with scleral buckles (p = 0.00041). In terms of the incidence of postoperative complications following intrascleral fixation, the incidence of low intraocular pressure postoperative was higher in the PPV group than that in the A-vit group, and a significant difference was observed between the two groups (p = 0.01). CONCLUSIONS: The visual outcome and complications following intrascleral fixation did not differ according to the extent of vitreous excision.


Assuntos
Lentes Intraoculares , Vitrectomia , Humanos , Vitrectomia/efeitos adversos , Vitrectomia/métodos , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Acuidade Visual , Esclera/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia
5.
J Refract Surg ; 40(4): e199-e207, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593258

RESUMO

PURPOSE: To investigate the efficacy of incorporating Generative Adversarial Network (GAN) and synthetic images in enhancing the performance of a convolutional neural network (CNN) for automated estimation of Implantable Collamer Lens (ICL) vault using anterior segment optical coherence tomography (AS-OCT). METHODS: This study was a retrospective evaluation using synthetic data and real patient images in a deep learning framework. Synthetic ICL AS-OCT scans were generated using GANs and a secondary image editing algorithm, creating approximately 100,000 synthetic images. These were used alongside real patient scans to train a CNN for estimating ICL vault distance. The model's performance was evaluated using statistical metrics such as mean absolute percentage error (MAPE), mean absolute error (MAE), root mean squared error (RMSE), and coefficient of determination (R2) for the estimation of ICL vault distance. RESULTS: The study analyzed 4,557 AS-OCT B-scans from 138 eyes of 103 patients for training. An independent, retrospectively collected dataset of 2,454 AS-OCT images from 88 eyes of 56 patients, used prospectively for evaluation, served as the test set. When trained solely on real images, the CNN achieved a MAPE of 15.31%, MAE of 44.68 µm, and RMSE of 63.3 µm. However, with the inclusion of GAN-generated and algorithmically edited synthetic images, the performance significantly improved, achieving a MAPE of 8.09%, MAE of 24.83 µm, and RMSE of 32.26 µm. The R2 value was +0.98, indicating a strong positive correlation between actual and predicted ICL vault distances (P < .01). No statistically significant difference was observed between measured and predicted vault values (P = .58). CONCLUSIONS: The integration of GAN-generated and edited synthetic images substantially enhanced ICL vault estimation, demonstrating the efficacy of GANs and synthetic data in enhancing OCT image analysis accuracy. This model not only shows potential for assisting postoperative ICL evaluations, but also for improving OCT automation when data paucity is an issue. [J Refract Surg. 2024;40(4):e199-e207.].


Assuntos
Cristalino , Miopia , Lentes Intraoculares Fácicas , Humanos , Tomografia de Coerência Óptica/métodos , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Miopia/cirurgia
6.
J Refract Surg ; 40(4): e253-e259, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593262

RESUMO

PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q-values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within ±0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes. [J Refract Surg. 2024;40(4):e253-e259.].


Assuntos
Ceratocone , Lentes Intraoculares , Facoemulsificação , Humanos , Ceratocone/diagnóstico , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Facoemulsificação/métodos , Óptica e Fotônica , Refração Ocular , Biometria/métodos
8.
Int Ophthalmol ; 44(1): 198, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662107

RESUMO

PURPOSE: Cataract surgery in microphthalmic eyes is challenging due to anatomical restraints, hard bulky nucleus. This series aims to evaluate the safety and efficacy of couching of intraocular lens in irido-fundal coloboma with microphthalmos. SETTING: Tertiary care centre in South India. DESIGN: Retrospective non-comparative study in eyes with irido-fundal coloboma, corneal diameter < 7 mm and brown cataract. Visual acuity less than 6/60 in other eye. METHODS: Anterior chamber entry made, zonules broken and lens dislocated into the vitreous cavity in a controlled manner. Baseline Clinico-demographic details, corrected distance visual acuity (CDVA), Intra-ocular pressure (IOP), corneal diameter, axial length, lens status and post-surgery CDVA, IOP and complications recorded and followed up for atleast 6 months. RESULTS: Fifteen eyes of 15 subjects were evaluated with a mean age 49.4 ± 10.9 years. At baseline, mean IOP 14.5 ± 3.8 mmHg, mean axial length 19.3 ± 0.5 mm, mean corneal diameter was 6.5 ± 0.34 mm and CDVA 2 logMAR which improved to 1.5 logMAR at 3 months (p value 0.002). Transient spike in IOP in 33.3% subjects was medically managed with no significant difference in IOP (p > 0.05) at baseline (14.5 ± 3.8 mmHg), 3 months post-surgery (16 ± 2.8 mmHg) and 6 months post-surgery (14.9 ± 2.5 mmHg). One patient underwent re-couching. No other major complications were noted. CONCLUSION: Couching of cataractous lens is an effective and safe method in microphthalmic eyes with irido-fundal coloboma as last resort procedure, where no other surgical procedure may work. It provides an ambulatory gain of visual acuity in previously non-ambulatory subjects. Corneal measurements help in determining the subset of patients where couching offers viable option.


Assuntos
Catarata , Coloboma , Microftalmia , Acuidade Visual , Humanos , Estudos Retrospectivos , Feminino , Coloboma/diagnóstico , Coloboma/complicações , Coloboma/cirurgia , Masculino , Microftalmia/complicações , Microftalmia/diagnóstico , Microftalmia/cirurgia , Catarata/complicações , Catarata/congênito , Catarata/diagnóstico , Pessoa de Meia-Idade , Adulto , Iris/cirurgia , Iris/anormalidades , Implante de Lente Intraocular/métodos , Extração de Catarata/métodos , Cristalino/anormalidades , Cristalino/cirurgia , Seguimentos
9.
Turk J Ophthalmol ; 54(2): 63-68, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38644781

RESUMO

Objectives: To evaluate the clinical results of a new trifocal intraocular lens (IOL) with sinusoidal design by comparing with a traditional trifocal IOL. Materials and Methods: A total of 79 patients undergoing uneventful microincisional cataract surgery with bilateral implantation of one of two types of trifocal IOLs, the Acriva Trinova IOL (VSY) or Acrysof IQ PanOptix IOL (Alcon), were enrolled in this prospective study. Visual and refractive outcomes, contrast sensitivity (CS), and defocus curve were assessed at 3 months after surgery. Patient satisfaction and incidence of photic phenomena were also evaluated. Results: The number of patients/eyes were 48/96 in the Trinova group and 31/62 in the PanOptix group. There were no significant differences between the groups for monocular and binocular corrected/uncorrected distance or intermediate (at 60 cm) and near visual acuities (VA) postoperatively. The Trinova group had statistically significantly better intermediate VA at 80 cm than the PanOptix group (p<0.05). The CS results of both groups were within the normal limits. In the binocular defocus curve of both IOLs, we observed a peak of good VA at 0.0 diopters defocus and a useful wide range for intermediate distances. The incidence of photic phenomena in the Trinova group was lower at postoperative 1 month (p<0.05) but this difference disappeared at 3 months. A total of 47 patients (97.9%) in the Trinova group and 30 patients (96.7%) in the PanOptix group stated that they would recommend the same IOL. Conclusion: Both trifocal IOLs provide good visual quality outcomes and patient satisfaction.


Assuntos
Lentes Intraoculares Multifocais , Presbiopia , Desenho de Prótese , Refração Ocular , Acuidade Visual , Humanos , Estudos Prospectivos , Feminino , Masculino , Acuidade Visual/fisiologia , Idoso , Pessoa de Meia-Idade , Presbiopia/fisiopatologia , Presbiopia/cirurgia , Refração Ocular/fisiologia , Visão Binocular/fisiologia , Satisfação do Paciente , Sensibilidades de Contraste/fisiologia , Facoemulsificação , Seguimentos , Implante de Lente Intraocular/métodos , Lentes Intraoculares
10.
Klin Monbl Augenheilkd ; 241(4): 374-377, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38653291

RESUMO

BACKGROUND: In cataract surgery, intraocular lenses (IOLs) with enhanced depth of focus are an option to correct presbyopia. The purpose of this quality assurance analysis was to evaluate visual acuity and patient satisfaction after implantation of the Hoya Vivinex Impress IOL. METHODS: The Hoya Vivinex Impress IOL was implanted in patients undergoing cataract surgery at the Pallas Klinik, Olten, Switzerland. Five weeks postoperatively, a clinical examination and a survey on patient satisfaction were conducted. RESULTS: A total of 17 eyes (9 patients; mean age 64 years) underwent cataract surgery with implantation of a Hoya Vivinex Impress IOL. Five weeks postoperatively, mean uncorrected distance visual acuity (UDVA) was 0.2 logMAR, uncorrected intermediate visual acuity (UIVA) was 0.0 logMAR, and uncorrected near visual acuity (UNVA) was 0.2 logMAR. The mean distance-corrected visual acuity results were 0.0 logMAR, 0.1 logMAR, and 0.3 logMAR, respectively. Reading the newspaper without glasses was possible for 33.4% of patients. Visual disturbances such as halos and glares were not reported. CONCLUSION: Cataract surgery with Hoya Vivinex Impress IOL implantation revealed good distance and intermediate vision and, in some patients, functional near vision as well as a high patient satisfaction.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Satisfação do Paciente , Desenho de Prótese , Acuidade Visual , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Resultado do Tratamento , Idoso , Implante de Lente Intraocular/métodos , Percepção de Profundidade/fisiologia , Análise de Falha de Equipamento , Extração de Catarata/métodos
11.
J Cataract Refract Surg ; 50(5): 505-510, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651698

RESUMO

PURPOSE: To compare flange depth for a modified scleral pocket (SP) vs no scleral pocket (NSP) technique (Yamane technique) for intrascleral intraocular lens (IOL) fixation. SETTING: Instituto de Oftalmología Santa Fe, Santa Fe, Argentina. DESIGN: Prospective, randomized, single-surgeon, observational study. METHODS: Eyes with aphakia and no capsular support were included. They were divided into 2 groups: one was programmed for a double-needle flanged intrascleral IOL fixation as originally described by Shin Yamane with NSP and the second group had a modified SP technique. Flange depth was measured with anterior-segment optical coherence tomography (AS-OCT) at 1 month, 3 months, 6 months, and 12 months postoperatively, and the results were compared. RESULTS: Each group comprised 18 eyes of 18 patients, giving a total of 36 flanges per group. The groups were comparable preoperatively. At 12 months, uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were not statistically different for both groups (P = .333; P = .448). Spherical equivalent (SEQ) was not significantly different between groups at 12 months postoperatively (P = .078). AS-OCT revealed a significantly deeper flange position for the SP group at 1 month, 3 months, 6 months, and 12 months postoperatively (P < .05). CONCLUSIONS: When performing a double-needle intrascleral IOL fixation in aphakic eyes with no capsular support, a modified scleral pocket technique provides a significantly deeper flange position with no difference in CDVA or SEQ 12 months postoperatively.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Esclera , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Esclera/cirurgia , Implante de Lente Intraocular/métodos , Estudos Prospectivos , Acuidade Visual/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Afacia Pós-Catarata/cirurgia , Afacia Pós-Catarata/fisiopatologia , Retalhos Cirúrgicos , Técnicas de Sutura , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia
12.
BMC Ophthalmol ; 24(1): 189, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658894

RESUMO

PURPOSE: To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification (PHACO) and femtosecond laser assisted cataract surgery (FLACS). SETTING: Department of Ophthalmology, Shanghai Aier Eye Hospital, China. DESIGN: A retrospective, observational study. METHODS: Patients who underwent cataract surgery combined with Acrysoft IQ PanOptix trifocal IOL implantation were enrolled and divided into three groups: PHACO group, LAstig-FLACS group (astigmatism less then 1D) and HAstig-FLACS group (astigmatism more than 1D). Logarithm of the minimum angle of resolution (logMAR) visual acuity of uncorrected distance (UDVA), intermediate (UIVA), near visual (UNVA), defocus curve, surgically induced astigmatism (SIA) were evaluated in 1 months postoperatively and wavefront aberrations were evaluated in 6 months. RESULTS: 101 eyes of 60 patients were included with 31 eyes in PHACO group, 45 eyes in LAstig-FLACS group and 25 eyes in HAstig-FLACS group. Significant difference was found of internal Strehl Ratio (SR) between PHACO and LAstig-FLACS group (P = 0.026). In PHACO group, 79.31%, 86.21%, 72.41% of eyes gain visual acuity LogMAR 0.1 or more in UDVA, UIVA and UNVA, while 83.72%, 93.02%, 93.02% of those in LAstig-FLACS group and 92.00%, 84.00%, 76.00% in HAstig-FLACS group. CONCLUSIONS: Panoptix diffractive trifocal IOL provides satisfied visual outcome in no matter FLACS or PHACO. Besides, trifocal IOL implantation via FLACS can provide a better accumulative visual acuity outcome at all distance than PHACO in 1 month. Femtosecond laser assisted limbal relaxing incisions (FLLRIs) is an excellent way to reduce a patient's corneal astigmatism.


Assuntos
Terapia a Laser , Lentes Intraoculares Multifocais , Facoemulsificação , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Masculino , Feminino , Facoemulsificação/métodos , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Terapia a Laser/métodos , Idoso , Refração Ocular/fisiologia , Implante de Lente Intraocular/métodos , Pseudofacia/fisiopatologia , Resultado do Tratamento , Desenho de Prótese , Extração de Catarata/métodos , Seguimentos
13.
Jpn J Ophthalmol ; 68(3): 200-205, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38587787

RESUMO

PURPOSE: To evaluate the surgical outcomes of intrascleral intraocular lens (IOL) fixation using ab interno trabeculotomy (LOT) in patients with exfoliation glaucoma with lens subluxation. STUDY DESIGN: Retrospective case series. METHODS: Twenty eyes of 18 patients with exfoliation glaucoma and lens or IOL subluxations were included. Three success criteria were based on postoperative intraocular pressure (IOP) (A, ≤15 mmHg; B, ≤18 mmHg; C, ≤21 mmHg). The IOP, number of glaucoma medications, and visual acuity were compared before and after surgery. Success probability was analyzed using Kaplan-Meier survival curves. Cox proportional hazards' regression models were used to examine prognostic factors for surgical failure. RESULTS: The mean follow-up period was 23.4 ± 7.8 months. The mean IOP significantly decreased from 23.2 ± 6.8 mmHg preoperatively to 14.0 ± 4.4 mmHg at 1 year postoperative (P<0.001). Postoperative hyphema and vitreous hemorrhage were observed in seven and 15 eyes, respectively, and washout in the anterior chamber or vitreous cavity was performed in four eyes. Postoperative IOP spikes and hypotony were observed in four eyes each. Glaucoma reoperation was performed in two eyes. The success rates at 12 months were 65%, 85%, and 90% using criteria A, B, and C, respectively. The IOP at 1 month after surgery was a significant prognostic factor for surgical failure according to criterion A (hazard ratio: 1.08; P=0.034). CONCLUSION: Intrascleral IOL fixation combined with microhook LOT is a promising option in cases of exfoliation glaucoma with subluxated lens/IOL; however, the high rate of postoperative hyphema and vitreous hemorrhage should be noted.


Assuntos
Síndrome de Exfoliação , Pressão Intraocular , Implante de Lente Intraocular , Subluxação do Cristalino , Esclera , Trabeculectomia , Acuidade Visual , Humanos , Estudos Retrospectivos , Masculino , Feminino , Idoso , Esclera/cirurgia , Síndrome de Exfoliação/fisiopatologia , Síndrome de Exfoliação/cirurgia , Síndrome de Exfoliação/complicações , Trabeculectomia/métodos , Pressão Intraocular/fisiologia , Acuidade Visual/fisiologia , Subluxação do Cristalino/cirurgia , Subluxação do Cristalino/fisiopatologia , Subluxação do Cristalino/diagnóstico , Seguimentos , Pessoa de Meia-Idade , Implante de Lente Intraocular/métodos , Idoso de 80 Anos ou mais , Lentes Intraoculares , Resultado do Tratamento
15.
Eye (Lond) ; 38(Suppl 1): 4-8, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38580743

RESUMO

OBJECTIVES: The purpose of this study is to evaluate the optical and expected clinical performance of a new refractive Extended Depth of Focus (EDF) intraocular lens (IOL) designed to maintain a monofocal-like dysphotopsia profile. METHODS: Simulated visual acuity (sVA) with varying defocus was calculated using the area under the Modulation Transfer Function measured in an average eye model and from computer simulations in eye models with corneal higher-order aberrations. Tolerance to defocus was evaluated using computer simulations of the uncorrected distance sVA under defocus. To evaluate the dysphotopsia profile, halo pictures obtained using an IOL-telescope, as well as simulated images in a realistic eye model under defocus were assessed. The results of the refractive EDF were compared to those of a diffractive EDF of the same platform. RESULTS: The refractive EDF IOL provides similar range of vision to the diffractive EDF IOL with the same distance, and similar intermediate and near sVA. The refractive EDF IOL provides the same tolerance to hyperopia as the diffractive EDF but more tolerance to myopia. Halo pictures and simulations showed that the refractive EDF provides comparable dysphotopsia profile to the monofocal IOL and better than the diffractive EDF. CONCLUSIONS: The results of this preclinical study in clinically relevant conditions show that the new refractive EDF IOL is expected to provide similar range of vision to the diffractive IOL of the same platform and higher tolerance to refractive errors. The refractive EDF provides a dysphotopsia profile that is better than the diffractive EDF and comparable to that of the monofocal IOL, also in the presence of residual refractive errors.


Assuntos
Simulação por Computador , Lentes Intraoculares , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Percepção de Profundidade/fisiologia , Desenho de Prótese , Óptica e Fotônica , Transtornos da Visão/fisiopatologia , Implante de Lente Intraocular/métodos
16.
Int Ophthalmol ; 44(1): 203, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671195

RESUMO

PURPOSE: This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery. METHODS: This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic capture in Berger space was performed on 33 patients (48 eyes) with pediatric cataract at Qingdao Eye Hospital. Tilt and decentration of IOL was measured using Scheimpflug system (Pentacam) at 1 month and 2 years postoperatively. RESULTS: All the multifocal IOLs were successfully implanted in Berger space with optic capture and no visually significant complications were detected during the follow-up. The mean tilt of IOLs was 2.779° ± 0.950° in the vertical plane and 2.399° ± 0.898° in the horizontal plane at 1 month postoperatively, and the mean length of the decentration was 0.207 ± 0.081 mm in vertical plane and 0.211 ± 0.090 mm in the horizontal plane. Compared with 1 month after surgery, the angle of tilt decreased by a mean of 0.192° and decentration increased by a mean of 0.014 mm at the vertical meridian at 2 years postoperatively (P = 0.37 and P = 0.27, respectively), meanwhile, tilt increased by 0.265° and decentration increased by 0.012 mm at the horizontal meridian (P = 0.11 and P = 0.22, respectively). CONCLUSIONS: The follow-up results suggest the tilt and decentration of multifocal IOL implantation with optic capture in Berger space remain stable in an acceptable range within 2 years after cataract surgery in children above the age of 5. TRIAL REGISTRATION: The study was approved by the Ethics Committee of Qingdao Eye Hospital, and registered on Chinese Clinical Trial Registry (ChiCTR identifier: 1900023155).


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares Multifocais , Acuidade Visual , Humanos , Masculino , Feminino , Estudos Prospectivos , Catarata/complicações , Catarata/fisiopatologia , Pré-Escolar , Criança , Extração de Catarata/métodos , Extração de Catarata/efeitos adversos , Seguimentos , Desenho de Prótese , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/fisiopatologia , Migração do Implante de Lente Intraocular/etiologia , Migração do Implante de Lente Intraocular/cirurgia , Implante de Lente Intraocular/métodos , Lactente
17.
J Refract Surg ; 40(3): e142-e147, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466767

RESUMO

PURPOSE: To evaluate the accuracy of the Reinstein formula with hand-held ultrasound biomicroscopy (UBM) measurements for sizing of the Implantable Collamer Lens (ICL). METHODS: A total of 107 myopic eyes of 57 patients implanted with the ICL were included in the study. The size of the ICL was selected based on the manufacturer's recommendations. Agreement between the vault predicted by the Reinstein formula and the vault measured postoperatively was analyzed with Bland-Altman plots. RESULTS: A total of 95% and 81% of patients had a postoperative vault ranging from 150 to 1,000 and 250 to 750 µm, respectively. The mean vault predicted by the Reinstein formula and the postoperative vault in the current study were 580 ± 181 and 547 ± 200 µm, respectively. The size recommendations of the Reinstein formula and the formula provided by the manufacturer, the Kojima formula, and the Dougherty formula overlapped in 50%, 57%, and 49% of eyes, respectively. CONCLUSIONS: The results show that the Reinstein formula combined with a hand-held UBM provides reliable sizing predictions of the ICL. However, considering that robotic UBM measurements have demonstrated a narrower range of deviation in predicting vault depth in previous studies, a direct comparison study between robotic UBM and hand-held UBM measurements is necessary to fully assess the limitations of combining hand-held UBM with the Reinstein formula. [J Refract Surg. 2024;40(3):e142-e147.].


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Microscopia Acústica/métodos , Implante de Lente Intraocular/métodos , Acuidade Visual , Miopia/cirurgia , Estudos Retrospectivos
18.
J Refract Surg ; 40(3): e164-e172, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466765

RESUMO

PURPOSE: To evaluate the dynamic changes in anterior segment parameters during accommodation following Implantable Collamer Lens (ICL) implantation with swept-source optical coherence tomography (SS-OCT). METHODS: Under the accommodation of 0.00 diopters (D), 3.00 D, and maximum amplitude, SS-OCT was used to examine the anterior segment parameters, including ICL vault, ICL depth (the distance between the corneal endothelium and the posterior surface of ICL), crystalline lens thickness, anterior chamber depth, and various parameters of the anterior chamber angle, comprising angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle. RESULTS: During accommodation, the ICL vault showed a significant decrease from baseline (536 ± 278 µm) to 3.00 D (522 ± 281 µm), followed by an increase from 3.00 D to maximum amplitude (548 ± 306 µm) (analysis of variance [ANOVA], P < .001). Four eyes (2.61%) exhibited a decrease in ICL vault to less than 100 µm (47 ± 32 µm) at maximum accommodation. The ICL depth decreased significantly as accommodation increased (ANOVA, P < .001). Crystalline lens thickness increased, whereas anterior chamber depth decreased during accommodation (ANOVA, P < .001). The anterior chamber angle widened during 3.00 D of accommodation but narrowed at maximum accommodation, leading to significant changes in the angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle during accommodation (ANOVA, P < .001 for all). CONCLUSIONS: The anterior segment, including ICL vault and anterior chamber angle, undergo significant dynamic changes during accommodation. These accommodative changes may require careful monitoring for the surgery design of ICL implantation. [J Refract Surg. 2024;40(3):e164-e172.].


Assuntos
Cristalino , Miopia , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular/métodos , Miopia/cirurgia , Acomodação Ocular , Câmara Anterior/diagnóstico por imagem , Pseudofacia/cirurgia , Tomografia de Coerência Óptica , Biometria
19.
Int Ophthalmol ; 44(1): 151, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38507136

RESUMO

PURPOSE: To identify the rate and characteristics of cataract surgery candidates suitable for multifocal intraocular lens implantation among patients undergoing preoperative evaluation in a public hospital. MATERIALS AND METHODS: Screening was performed based on the patient's medical records, comprehensive ophthalmic examination, optical biometry (Zeiss, IOL Master 700) and optical coherence tomography (OCT) (Heidelberg, OCT Spectralis) in accordance with the relevant indications and contraindications mentioned in the pertinent literature. Patients were included in the present study if they were eligible for bilateral cataract surgery. The exclusion criteria were the presence of central nervous system or motility issues, prior refractive surgery, the presence of astigmatism greater than 1 dioptre and/or the presence of important ocular comorbidities in either eye. RESULTS: The study evaluated 1200 consecutive patients. Four hundred thirty-two patients (36%) were not eligible for bilateral surgery and were excluded from the study. Of the 768 patients included in the present study, 346 (45.1%) were considered suitable candidates. Four hundred twenty-two patients (54.9%) were excluded for one or both eyes. Among them, 121 (28.7%) were excluded because of retinal disease, 120 (28.4%) because of regular astigmatism (> 1.0 D of corneal astigmatism), 32 (7.5%) because of pseudoexfoliation or zonular instability, and 30 (7.1%) because of glaucoma or ocular hypertension; in addition, 90 (21.3%) patients were excluded for multiple reasons. Suitable candidates were significantly younger (70 and 75 years, respectively) (p < 0.001). After being informed about the potential risks and benefits of MOIL implantation, 212 of 346 (83.8%) eligible patients provided consent. CONCLUSION: Close to half of cataract patients in a public hospital were eligible for MOIL implantation, and the majority of patients would proceed to surgery. The most prevalent contraindication was macular disease.


Assuntos
Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Lentes Intraoculares/efeitos adversos , Acuidade Visual , Facoemulsificação/métodos , Catarata/complicações , Catarata/epidemiologia , Refração Ocular
20.
Int Ophthalmol ; 44(1): 152, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509438

RESUMO

PURPOSE: To evaluate and compare the clinical outcomes of three different methods of intraocular lens (IOL) implantation in the surgery of subluxated cataracts. METHODS: In this retrospective, comparative, clinical interventional study, the medical records of patients who underwent IOL implantation with sutureless 27-gauge needle-assisted transconjunctival intrascleral (Group 1), Z-suture knotless transscleral (Group 2), and Cionni capsular tension ring (Cionni-CTR) assisted (Group 3) simultaneously with subluxated cataract extraction between June 2010 and June 2022 were evaluated. Demographic characteristics, follow-up times, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical and cylindrical refractive values, and spherical equivalent (SE) values of three groups were compared. Intraoperative and postoperative complications were recorded. RESULTS: There were 20 eyes in Group 1, 35 eyes in Group 2, and 40 eyes in Group 3. In all groups, statistically significant improvement was observed in postoperative UDVA and CDVA compared to preoperative values (each p < 0.05). There was no statistical difference between the groups in postoperative UDVA and CDVA values. (p = 0.130, p = 0.167 respectively). No significant difference was observed between the groups in terms of postoperative spherical, cylindrical, and SE values (each p > 0.05). CONCLUSION: The study suggests that three different IOL implantation techniques for simultaneous IOL implantation in subluxated cataract surgery have similar effects on visual and refractive outcomes.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Humanos , Implante de Lente Intraocular/métodos , Lentes Intraoculares/efeitos adversos , Estudos Retrospectivos , Extração de Catarata/efeitos adversos , Catarata/complicações , Suturas/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...