Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30.095
Filtrar
1.
J Long Term Eff Med Implants ; 34(4): 1-13, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38842228

RESUMO

We present the design and stability analysis of an adaptive neuro-fuzzy inference system (ANFIS)-based controller of a pacemaker in MATLAB Simulink. ANFIS uses learning and speed properties of fuzzy and neural networks. Based on body states and preprogrammed situations of patients (age and sex, etc.), heart rate and amplitude of pacing pulse are changed. Output signal that is fed backed from heart is compared to the reference fuzzy bases ANFIS signals. After designing ANFIS based controller, the stability of the proposed system has been tested in both the time (step response) and trequency (Bode diagram and Nichols chart) domains. In our previous study, the step response analyzed and compared with other works. For frequency domain, all the possible frequency analysis methods have been tested but because of nonlinear properties of ANFIS, after linearization, just the Bode diagram achieved good results. The step response results in time domain is compared with previous work's results including optimum heart pulse rate for each particular patient. In the frequency domain, the Bode diagram stability analysis showed gain and phase margin as follows: GM (dB) = 42.1 and PM (deg) = 100.


Assuntos
Lógica Fuzzy , Frequência Cardíaca , Redes Neurais de Computação , Marca-Passo Artificial , Humanos , Desenho de Equipamento , Simulação por Computador , Algoritmos
3.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38833618

RESUMO

AIMS: Debulking of infective mass to reduce the burden if infective material is a fundamental principle in the surgical management of infection. The aim of this study was to investigate the validity of this principle in patients undergoing transvenous lead extraction in the context of bloodstream infection (BSI). METHODS AND RESULTS: We performed an observational single-centre study on patients that underwent transvenous lead extraction due to a BSI, with or without lead-associated vegetations, in combination with a percutaneous aspiration system during the study period 2015-22. One hundred thirty-seven patients were included in the final analysis. In patients with an active BSI at the time of intervention, the use of a percutaneous aspiration system had a significant impact on survival (log-rank: P = 0.0082), while for patients with a suppressed BSI at the time of intervention, the use of a percutaneous aspiration system had no significant impact on survival (log-rank: P = 0.25). CONCLUSION: A reduction of the infective burden by percutaneous debulking of lead vegetations might improve survival in patients with an active BSI.


Assuntos
Remoção de Dispositivo , Infecções Relacionadas à Prótese , Humanos , Feminino , Masculino , Remoção de Dispositivo/métodos , Idoso , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/mortalidade , Pessoa de Meia-Idade , Resultado do Tratamento , Desfibriladores Implantáveis/efeitos adversos , Sucção , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/microbiologia , Endocardite Bacteriana/cirurgia , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/etiologia , Estudos Retrospectivos , Fatores de Tempo , Fatores de Risco , Idoso de 80 Anos ou mais
4.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38866455

RESUMO

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Idoso , Fatores de Tempo , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Estados Unidos/epidemiologia
6.
Radiol Cardiothorac Imaging ; 6(3): e230303, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38869431

RESUMO

Purpose To examine the clinical effect of lead length and lead orientation in patients with cardiac implantable electronic devices (CIEDs) and lead fragments or abandoned leads undergoing 1.5-T MRI. Materials and Methods This Health Insurance Portability and Accountability Act-compliant retrospective study included patients with CIEDs and abandoned leads or lead fragments undergoing 1.5-T MRI from March 2014 through July 2020. CIED settings before and after MRI were reviewed, with clinically significant variations defined as a composite of the change in capture threshold of at least 50%, in sensing of at least 40%, or in lead impedance of at least 30% between before MRI and after MRI interrogation. Adverse clinical events were assessed at MRI and up to 30 days after. Univariable and multivariable analysis was performed. Results Eighty patients with 126 abandoned CIED leads or lead fragments underwent 107 1.5-T MRI examinations. Sixty-seven patients (median age, 74 years; IQR, 66-78 years; 44 male patients, 23 female patients) had abandoned leads, and 13 (median age, 66 years; IQR, 52-74 years; nine male patients, four female patients) had lead fragments. There were no reported deaths, clinically significant arrhythmias, or adverse clinical events within 30 days of MRI. Three patients with abandoned leads had a significant change in the composite of capture threshold, sensing, or lead impedance. In a multivariable generalized estimating equation analysis, lead orientation, lead length, MRI type, and MRI duration were not associated with a significant change in the composite outcome. Conclusion Use of 1.5-T MRI in patients with abandoned CIED leads or lead fragments of varying length and orientation was not associated with adverse clinical events. Keywords: Cardiac Assist Devices, MRI, Cardiac Implantable Electronic Device Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Marca-Passo Artificial/efeitos adversos , Pessoa de Meia-Idade , Falha de Equipamento/estatística & dados numéricos
7.
Zhonghua Xin Xue Guan Bing Za Zhi ; 52(6): 684-689, 2024 Jun 24.
Artigo em Chinês | MEDLINE | ID: mdl-38880748

RESUMO

Objective: To explore the feasibility and safety of remote programming technology based on 5G cloud technology support platform in postoperative follow-up of cardiovascular implantable electronic devices(CIED). Methods: This study was a multicenter cross-sectional study. CIED patients from 12 hospitals lacking full-time follow-up specialists in Sichuan Province were enrolled from June 2021 to October 2021. All patients' devices received remote inspecting and programming by the follow-up specialist of the remote follow-up center of the Third People's Hospital of Chengdu through 5G cloud technology support platform. The baseline data, device alarm events, device reprogramming events, adverse reactions and satisfaction questionnaire survey results were collected. Results: A total of 195 CIED implantation patients were included, with an age of (72.5±11.3) years, including 103 males (52.6%). All patients completed remote inspecting and programming successfully, with a duration of (5.8±4.0) min. Ninety-one patients' CIED were reprogrammed, with a total of 104 parameter adjustments. No abnormal communication or adverse events occurred. The satisfaction questionnaire showed that 97.9%(191/195) of the patients trusted or relatively trusted remote follow-up and 86.7%(169/195) of the patients were willing to choose remote follow-up mode for device management. Conclusion: The remote programming based on 5G cloud technology support platform may be feasible and safe for postoperative follow-up of CIED patients.


Assuntos
Desfibriladores Implantáveis , Humanos , Masculino , Idoso , Feminino , Estudos Transversais , Inquéritos e Questionários , Marca-Passo Artificial , Estudos de Viabilidade , Período Pós-Operatório , Computação em Nuvem , Pessoa de Meia-Idade , Seguimentos , Satisfação do Paciente
8.
Card Electrophysiol Clin ; 16(2): 157-161, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749635

RESUMO

Cardiac implantable electronic device leads can contribute to tricuspid regurgitation and also complicate surgical and transcatheter interventions to manage tricuspid regurgitation. Here we present a case of a patient with sinus node dysfunction and complete heart block who underwent extraction of a right ventricular pacing lead before tricuspid valve surgery. We review the data regarding the contribution of leads to tricuspid regurgitation and the benefits of lead extraction, risks of jailing leads during tricuspid interventions, and pacing considerations around tricuspid valve procedures.


Assuntos
Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Marca-Passo Artificial/efeitos adversos , Masculino , Idoso , Bloqueio Cardíaco/terapia , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Feminino
9.
Card Electrophysiol Clin ; 16(2): 133-138, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749631

RESUMO

Persistent left superior vena cava (PLSVC) is an anatomic variant that is relatively uncommon in the general population. Lead extraction through PLSVC is extremely rare. Due to unusual anatomy, the procedure carries challenges that require special considerations and careful planning. The authors report a case of lead extraction through a PLSVC with occluded right superior vena cava and highlight the challenges and outcomes of the procedure.


Assuntos
Remoção de Dispositivo , Síndrome da Veia Cava Superior , Veia Cava Superior , Humanos , Veia Cava Superior/anormalidades , Veia Cava Superior/cirurgia , Veia Cava Superior/diagnóstico por imagem , Síndrome da Veia Cava Superior/cirurgia , Síndrome da Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior Esquerda Persistente/cirurgia , Veia Cava Superior Esquerda Persistente/diagnóstico por imagem , Masculino , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino
10.
Port J Card Thorac Vasc Surg ; 31(1): 57-58, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38743518

RESUMO

Surgical resection remains the optimal therapeutic option for early-stage operable NSCLC. Despite significant advances in recent years related to anesthetic and surgical techniques, cardiopulmonary complications remain major causes for postoperative morbimortality. In this paper we present a case of a patient who developed complete AV block followed by asystole after lung resection surgery. The patient underwent surgery via right VATS and the procedure was uneventful.  On the first post-operative day patient developed a third-degree atrioventricular block followed by 6 seconds asystole. Pharmacological treatment was instituted and implementation of a permanent pacemaker occurred on the third post-operative day, without complications. The remaining postoperative course was uneventful and the patient was discharged home on the sixth post-operative day. It is the objective of the authors to report and highlight this rare and potencial fatal complication of lung resection.


Assuntos
Bloqueio Atrioventricular , Parada Cardíaca , Neoplasias Pulmonares , Pneumonectomia , Humanos , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/diagnóstico , Parada Cardíaca/etiologia , Neoplasias Pulmonares/cirurgia , Pneumonectomia/efeitos adversos , Masculino , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Marca-Passo Artificial/efeitos adversos , Idoso , Cirurgia Torácica Vídeoassistida/efeitos adversos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia
11.
Sci Rep ; 14(1): 11130, 2024 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750100

RESUMO

CMR at 3.0T in the presence of active cardiac implants remains a challenge due to susceptibility artifacts. Beyond a signal void that cancels image information, magnetic field inhomogeneities may cause distorted appearances of anatomical structures. Understanding influencing factors and the extent of distortion are a first step towards optimizing the image quality of CMR with active implants at 3.0T. All measurements were obtained at a clinical 3.0T scanner. An in-house designed phantom with a 3D cartesian grid of water filled spheres was used to analyze the distortion caused by four representative active cardiac devices (cardiac loop recorder, pacemaker, 2 ICDs). For imaging a gradient echo (3D-TFE) sequence and a turbo spin echo (2D-TSE) sequence were used. The work defines metrics to quantify the different features of distortion such as changes in size, location and signal intensity. It introduces a specialized segmentation technique based on a reaction-diffusion-equation. The distortion features are dependent on the amount of magnetic material in the active implants and showed a significant increase when measured with the 3D TFE compared to the 2D TSE. This work presents a quantitative approach for the evaluation of image distortion at 3.0T caused by active cardiac implants and serves as foundation for both further optimization of sequences and devices but also for planning of imaging procedures.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Artefatos , Marca-Passo Artificial
12.
Arq Bras Cardiol ; 121(4): e20230386, 2024 Apr.
Artigo em Português, Inglês | MEDLINE | ID: mdl-38695408

RESUMO

BACKGROUND: The use of artificial cardiac pacemakers has grown steadily in line with the aging population. OBJECTIVES: To determine the rates of hospital readmissions and complications after pacemaker implantation or pulse generator replacement and to assess the impact of these events on annual treatment costs from the perspective of the Unified Health System (SUS). METHODS: A prospective registry, with data derived from clinical practice, collected during index hospitalization and during the first 12 months after the surgical procedure. The cost of index hospitalization, the procedure, and clinical follow-up were estimated according to the values reimbursed by SUS and analyzed at the patient level. Generalized linear models were used to study factors associated with the total annual treatment cost, adopting a significance level of 5%. RESULTS: A total of 1,223 consecutive patients underwent initial implantation (n=634) or pulse generator replacement (n=589). Seventy episodes of complication were observed in 63 patients (5.1%). The incidence of hospital readmissions within one year was 16.4% (95% CI 13.7% - 19.6%) after initial implants and 10.6% (95% CI 8.3% - 13.4%) after generator replacements. Chronic kidney disease, history of stroke, length of hospital stays, need for postoperative intensive care, complications, and hospital readmissions showed a significant impact on the total annual treatment cost. CONCLUSIONS: The results confirm the influence of age, comorbidities, postoperative complications, and hospital readmissions as factors associated with increased total annual treatment cost for patients with pacemakers.


FUNDAMENTO: O uso de marca-passos cardíacos artificiais tem crescido constantemente, acompanhando o envelhecimento populacional. OBJETIVOS: Determinar as taxas de readmissões hospitalares e complicações após implante de marca-passo ou troca de gerador de pulsos e avaliar o impacto desses eventos nos custos anuais do tratamento sob a perspectiva do Sistema Único de Saúde (SUS). MÉTODOS: Registro prospectivo, com dados derivados da prática clínica assistencial, coletados na hospitalização índice e durante os primeiros 12 meses após o procedimento cirúrgico. O custo da hospitalização índice, do procedimento e do seguimento clínico foram estimados de acordo com os valores reembolsados pelo SUS e analisados ao nível do paciente. Modelos lineares generalizados foram utilizados para estudar fatores associados ao custo total anual do tratamento, adotando-se um nível de significância de 5%. RESULTADOS: No total, 1.223 pacientes consecutivos foram submetidos a implante inicial (n= 634) ou troca do gerador de pulsos (n= 589). Foram observados 70 episódios de complicação em 63 pacientes (5,1%). A incidência de readmissões hospitalares em um ano foi de 16,4% (IC 95% 13,7% - 19,6%) após implantes iniciais e 10,6% (IC 95% 8,3% - 13,4%) após trocas de geradores. Doença renal crônica, histórico de acidente vascular encefálico, tempo de permanência hospitalar, necessidade de cuidados intensivos pós-operatórios, complicações e readmissões hospitalares mostraram um impacto significativo sobre o custo anual total do tratamento. CONCLUSÕES: Os resultados confirmam a influência da idade, comorbidades, complicações pós-operatórias e readmissões hospitalares como fatores associados ao incremento do custo total anual do tratamento de pacientes com marca-passo.


Assuntos
Marca-Passo Artificial , Readmissão do Paciente , Humanos , Marca-Passo Artificial/economia , Marca-Passo Artificial/efeitos adversos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Readmissão do Paciente/estatística & dados numéricos , Readmissão do Paciente/economia , Fatores de Tempo , Idoso de 80 Anos ou mais , Estudos Prospectivos , Complicações Pós-Operatórias/economia , Brasil , Custos de Cuidados de Saúde/estatística & dados numéricos , Fatores de Risco , Tempo de Internação/economia
14.
Med Sci Monit ; 30: e944114, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38776271

RESUMO

BACKGROUND Long-term right ventricular (RV) pacing has been linked to left atrial enlargement (LAE). The incidence and risk factors associated with significant LAE after RV pacing remain unknown. This retrospective study included 461 patients requiring RV pacing at 2 centers between 2012 and 2020 and aimed to evaluate the incidence, risk factors, outcomes, and complications of LAE. MATERIAL AND METHODS A total of 461 patients with normal-sized pre-implant left atrial dimension and dual-chamber pacing pacemaker implantation for complete atrioventricular block were enrolled. Patients were grouped based on a ≥20% increase from their baseline left atrial dimension by echocardiography, indicating significant LAE, and initial characteristics, echocardiographic data, and outcomes were compared. RESULTS During a mean 7.0±4.9 years follow-up period, 96 patients (20.8%) developed significant LAE, whereas 365 patients did not. In multivariate logistic regression analysis, smaller pre-implant left atrial dimension (OR, 0.776; 95% CI, 0.728-0.828; P<0.001), lower post-implant left ventricular ejection fraction (OR, 0.976; 95% CI, 0.957-0.995; P=0.014), post-implant development of moderate to severe mitral regurgitation (OR, 2.357; 95% CI, 1.172-4.740; P=0.016), and RV pacing duration ≥3.3 years (OR, 1.576; 95% CI, 1.039-2.646; P=0.045) were independent predictors of significant LAE after RV-dependent pacing. There was a significant difference in the incident stroke events between patients without and with significant LAE (9.9% vs 17.7%; log-rank P=0.047). CONCLUSIONS Long-term RV pacing was linked to significant LAE in 20.8% of patients with complete atrioventricular block, with those affected experiencing a higher stroke rate during follow-up.


Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia , Átrios do Coração , Ventrículos do Coração , Humanos , Feminino , Masculino , Estudos Retrospectivos , Fatores de Risco , Incidência , Idoso , Átrios do Coração/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Estimulação Cardíaca Artificial/efeitos adversos , Pessoa de Meia-Idade , Ventrículos do Coração/fisiopatologia , Ecocardiografia/métodos , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/fisiopatologia , Cardiomegalia/fisiopatologia , Marca-Passo Artificial , Resultado do Tratamento , Idoso de 80 Anos ou mais
15.
Rev Assoc Med Bras (1992) ; 70(4): e20230998, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38716936

RESUMO

OBJECTIVE: The use of cardiac implantable electronic devices has increased in recent years. It has also brought some issues. Among these, the complications of cardiac implantable electronic devices infection and pocket hematoma are difficult to manage. It can be fatal with the contribution of patient-related risk factors. In this study, we aimed to find mortality rates in patients who developed cardiac implantable electronic devices infection and pocket hematoma over 5 years. We also investigated the risk factors affecting mortality in patients with cardiac implantable electronic devices. METHODS: A total of 288 cardiac implantable electronic devices patients were evaluated. Demographic details, history, and clinical data of all patients were recorded. Cardiac implantable electronic devices infection was defined according to the modified Duke criteria. The national registry was used to ascertain the mortality status of the patients. The patients were divided into two groups (exitus and survival groups). In addition, the pocket hematoma was defined as significant bleeding at the pocket site after cardiac implantable electronic devices placement. RESULTS: The cardiac implantable electronic devices infection was similar in both groups (p=0.919), and the pocket hematoma was higher in the exitus group (p=0.019). The exitus group had higher usage of P2Y12 inhibitors (p≤0.001) and novel oral anticoagulants (p=0.031). The Cox regression analysis, including mortality-related factors, revealed that renal failure is the most significant risk factor for mortality. Renal failure was linked to a 2.78-fold higher risk of death. CONCLUSION: No correlation was observed between cardiac implantable electronic devices infection and mortality, whereas pocket hematoma was associated with mortality. Furthermore, renal failure was the cause of the highest mortality rate in patients with cardiac implantable electronic devices.


Assuntos
Desfibriladores Implantáveis , Hematoma , Marca-Passo Artificial , Humanos , Feminino , Masculino , Desfibriladores Implantáveis/efeitos adversos , Fatores de Risco , Idoso , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Hematoma/etiologia , Hematoma/mortalidade , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/etiologia , Estudos Retrospectivos , Fatores de Tempo , Idoso de 80 Anos ou mais
17.
Isr Med Assoc J ; 26(5): 273-277, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38736340

RESUMO

BACKGROUND: Cardiac implantable electronic devices (CIEDs) are increasingly being used; thus, there is an increasing need for transvenous lead extraction (TLE). OBJECTIVES: To summarize our experience with TLE at single referral center in northern Israel. METHODS: The study included all patients who underwent TLE at our center between 2019 and 2022, regardless of the indication. RESULTS: The cohort included 50 patients. The mean age was 69 ± 10.36 years; 78% were males. A total of 99 electrodes were targeted. The mean number of electrodes was 1.96 (range 1-4) per patient. The time between lead implantation and extraction ranged between 1.1 and 34 years with an average of 8.14 ± 5.71 years (median of 7.5 years). Complete lead removal was achieved in 98% of patients and in 98.99% of leads. The complete procedural success rate as well as the clinical procedural success rate was 96%. The procedural failure rate was 4% (1 patient died 2 days after the index procedure and 1 patient remained with large portion of lead). The indication for TLE was infection in 78% of the cohort group. Powered mechanical sheaths were used in 36 patients (72%), laser sheaths in 27 (54%), and a combination of laser and mechanical sheaths in 16 (32%). CONCLUSIONS: The clinical and procedural success rates of TLE, primarily for CEID-related infection, were high. A combination of laser and mechanical sheaths was needed in one-third of patients.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Humanos , Remoção de Dispositivo/métodos , Remoção de Dispositivo/estatística & dados numéricos , Masculino , Israel/epidemiologia , Feminino , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Pessoa de Meia-Idade , Eletrodos Implantados , Idoso de 80 Anos ou mais
18.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38749619

RESUMO

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Índice de Gravidade de Doença
19.
Card Electrophysiol Clin ; 16(2): 139-142, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749632

RESUMO

This case report discusses a 42-year-old male with dextro-transposition of the great arteries (D-TGA) status post Mustard repair and sick sinus syndrome status post dual-chamber pacemaker implant, who developed symptomatic superior vena cava (SVC) baffle stenosis. He was treated with a combined pacemaker extraction and subsequent SVC baffle stenting. The case highlights the complexities of treating SVC baffle stenosis in the presence of cardiac implantable devices and demonstrates the efficacy of this combined approach. Furthermore, the authors delve into the intricacies of D-TGA, its surgical history, and the long-term complications associated with atrial switch procedures.


Assuntos
Remoção de Dispositivo , Marca-Passo Artificial , Stents , Transposição dos Grandes Vasos , Humanos , Transposição dos Grandes Vasos/cirurgia , Masculino , Adulto , Marca-Passo Artificial/efeitos adversos , Síndrome da Veia Cava Superior/cirurgia , Síndrome da Veia Cava Superior/etiologia , Síndrome do Nó Sinusal/terapia , Síndrome do Nó Sinusal/cirurgia
20.
Card Electrophysiol Clin ; 16(2): 143-147, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749633

RESUMO

We present a complex case of cardiac implantable electronic device infection and extraction in the setting of bacteremia, large lead vegetation, and patent foramen ovale. Following a comprehensive preprocedural workup including transesophageal echocardiogram and computed tomography lead extraction protocol, in addition to the involvement of multiple subspecialties, an open chest approach to extraction was deemed a safer option for eradication of the patient's infection. Despite percutaneous techniques having evolved as the preferred extraction method during the last few decades, this case demonstrates the importance of a thorough evaluation at an experienced center to determine the need for open chest extraction.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Remoção de Dispositivo/métodos , Desfibriladores Implantáveis/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/diagnóstico por imagem , Marca-Passo Artificial/efeitos adversos , Masculino , Ecocardiografia Transesofagiana , Tomografia Computadorizada por Raios X , Idoso , Forame Oval Patente/cirurgia , Forame Oval Patente/diagnóstico por imagem , Feminino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...