Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50.416
Filtrar
2.
Nat Commun ; 15(1): 4777, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839748

RESUMO

Drawing inspiration from cohesive integration of skeletal muscles and sensory skins in vertebrate animals, we present a design strategy of soft robots, primarily consisting of an electronic skin (e-skin) and an artificial muscle. These robots integrate multifunctional sensing and on-demand actuation into a biocompatible platform using an in-situ solution-based method. They feature biomimetic designs that enable adaptive motions and stress-free contact with tissues, supported by a battery-free wireless module for untethered operation. Demonstrations range from a robotic cuff for detecting blood pressure, to a robotic gripper for tracking bladder volume, an ingestible robot for pH sensing and on-site drug delivery, and a robotic patch for quantifying cardiac function and delivering electrotherapy, highlighting the application versatilities and potentials of the bio-inspired soft robots. Our designs establish a universal strategy with a broad range of sensing and responsive materials, to form integrated soft robots for medical technology and beyond.


Assuntos
Robótica , Robótica/instrumentação , Robótica/métodos , Animais , Biomimética/métodos , Biomimética/instrumentação , Humanos , Próteses e Implantes , Pele , Desenho de Equipamento , Músculo Esquelético/fisiologia , Dispositivos Eletrônicos Vestíveis
3.
Int J Nanomedicine ; 19: 5011-5020, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38832337

RESUMO

Purpose: Atomic layer deposition (ALD) is a method that can deposit zirconia uniformly on an atomic basis. The effect of deposited zirconia on titanium implants using ALD was evaluated in vivo. Methods: Machined titanium implants (MTIs) were used as the Control. MTIs treated by sandblasting with large grit and acid etching (SA) and MTIs deposited with zirconia using ALD are referred to as Groups S and Z, respectively. Twelve implants were prepared for each group. Six rabbits were used as experimental animals. To evaluate the osteogenesis and osteocyte aspects around the implants, radiological and histological analyses were performed. The bone-to-implant contact (BIC) ratio was measured and statistically analyzed to evaluate the osseointegration capabilities. Results: In the micro-CT analysis, more radiopaque bone tissues were observed around the implants in Groups S and Z. Histological observation found that Groups S and Z had more and denser mature bone tissues around the implants in the cortical bone area. Many new and mature bone tissues were also observed in the medullary cavity area. For the BIC ratio, Groups S and Z were significantly higher than the Control in the cortical bone area (P < 0.017), but there was no significant difference between Groups S and Z. Conclusion: MTIs deposited with zirconia using ALD (Group Z) radiologically and histologically showed more mature bone formation and activated osteocytes compared with MTIs (Control). Group Z also had a significantly higher BIC ratio than the Control. Within the limitations of this study, depositing zirconia on the surface of MTIs using ALD can improve osseointegration in vivo.


Assuntos
Osseointegração , Titânio , Zircônio , Animais , Zircônio/química , Zircônio/farmacologia , Coelhos , Titânio/química , Titânio/farmacologia , Osseointegração/efeitos dos fármacos , Propriedades de Superfície , Microtomografia por Raio-X , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Interface Osso-Implante , Osteogênese/efeitos dos fármacos , Implantes Dentários , Próteses e Implantes
4.
J Refract Surg ; 40(6): e392-e397, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848056

RESUMO

PURPOSE: To compare the effects of corneal allogenic intrastromal ring segment (CAIRS) implantation on topographical measurements and visual outcomes of patients with keratoconus with and without corneal cross-linking (CXL) prior to the time of implantation. METHODS: Sixty-seven eyes with corneal allograft intrastromal ring segment implantation (KeraNatural; Lions VisionGift) due to advanced keratoconus were included in the study. Thirty-seven eyes had no CXL and 30 eyes had had CXL before being referred to the authors. The changes in spherical equivalent (SE), uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), steep keratometry (K1), flat keratometry (K2), mean keratometry (Kmean), maximum keratometry (Kmax), and thinnest pachymetry were retrospectively analyzed 6 months after the implantation. RESULTS: The median age was 29 years in the CXL group and 24.0 years in the non-CXL group (P > .05), respectively. All topographical and visual parameters before implantation were similar in both groups (P > .05 for all parameters). At 6 months, CDVA, K1, and Kmean showed higher improvement in the non-CXL group than the CXL group (P = .030, .018, and .039, respectively). CONCLUSIONS: CAIRS surgery has a flattening effect on both the corneas with and without CXL. The cornea with prior CXL treatment had less flattening effect due to the stiffening effect of prior CXL. [J Refract Surg. 2024;40(6):e392-e397.].


Assuntos
Colágeno , Substância Própria , Topografia da Córnea , Reagentes de Ligações Cruzadas , Ceratocone , Fármacos Fotossensibilizantes , Próteses e Implantes , Implantação de Prótese , Refração Ocular , Acuidade Visual , Humanos , Ceratocone/fisiopatologia , Ceratocone/metabolismo , Ceratocone/tratamento farmacológico , Ceratocone/cirurgia , Substância Própria/metabolismo , Substância Própria/cirurgia , Reagentes de Ligações Cruzadas/uso terapêutico , Acuidade Visual/fisiologia , Adulto , Masculino , Feminino , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Adulto Jovem , Refração Ocular/fisiologia , Colágeno/metabolismo , Paquimetria Corneana , Riboflavina/uso terapêutico , Fotoquimioterapia/métodos , Adolescente , Raios Ultravioleta , Transplante de Córnea/métodos , Pessoa de Meia-Idade , Crosslinking Corneano
5.
Transl Vis Sci Technol ; 13(5): 2, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38696181

RESUMO

Purpose: Currently, no solution exists to restore natural eyelid kinematics for patients with complete eyelid paralysis due to loss of function of both the levator palpebrae superioris and orbicularis oculi. These rare cases are prone to complications of chronic exposure keratopathy which may lead to corneal blindness. We hypothesized that magnetic force could be used to fully automate eyelid movement in these cases through the use of eyelid-attached magnets and a spectacle-mounted magnet driven by a programmable motor (motorized magnetic levator prosthesis [MMLP]). Methods: To test this hypothesis and establish proof of concept, we performed a finite element analysis (FEA) for a prototype MMLP to check the eyelid-opening force generated by the device and verified the results with experimental measurements in a volunteer with total bidirectional eyelid paralysis. The subject was then fitted with a prototype to check the performance of the device and its success. Results: With MMLP, eye opening was restored to near normal, and blinking was fully automated in close synchrony with the motor-driven polarity reversal, with full closure on the blink. The device was well tolerated, and the participant was pleased with the comfort and performance. Conclusions: FEA simulation results conformed to the experimentally observed trend, further supporting the proof of concept and design parameters. This is the first viable approach in human patients with proof of concept for complete reanimation of a bidirectionally paretic eyelid. Further study is warranted to refine the prototype and determine the feasibility and safety of prolonged use. Translational Relevance: This is first proof of concept for our device for total bidirectional eyelid paralysis.


Assuntos
Piscadela , Pálpebras , Estudo de Prova de Conceito , Humanos , Piscadela/fisiologia , Pálpebras/fisiopatologia , Doenças Palpebrais/fisiopatologia , Doenças Palpebrais/terapia , Músculos Oculomotores/fisiopatologia , Análise de Elementos Finitos , Fenômenos Biomecânicos , Próteses e Implantes , Desenho de Prótese , Imãs , Masculino
6.
J Orthop Surg Res ; 19(1): 273, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698477

RESUMO

BACKGROUND: Talar malignant tumor is extremely rare. Currently, there are several alternative management options for talus malignant tumor including below-knee amputation, tibio-calcaneal arthrodesis, and homogenous bone transplant while their shortcomings limited the clinical application. Three-dimensional (3D) printed total talus prosthesis in talus lesion was reported as a useful method to reconstruct talus, however, most researches are case reports and its clinical effect remains unclear. Therefore, the current study was to explore the application of 3D printed custom-made modular prosthesis in talus malignant tumor. METHODS: We retrospectively analyzed the patients who received the 3D printed custom-made modular prosthesis treatment due to talus malignant tumor in our hospital from February 2016 to December 2021. The patient's clinical data such as oncology outcome, operation time, and volume of blood loss were recorded. The limb function was evaluated with the Musculoskeletal Tumor Society 93 (MSTS-93) score, The American Orthopedic Foot and Ankle Society (AOFAS) score; the ankle joint ranges of motion as well as the leg length discrepancy were evaluated. Plain radiography and Tomosynthesis-Shimadzu Metal Artefact Reduction Technology (T-SMART) were used to evaluate the position of prosthesis and the osseointegration. Postoperative complications were recorded. RESULTS: The average patients' age and the follow-up period were respectively 31.5 ± 13.1 years; and 54.8 months (range 26-72). The medium operation time was 2.4 ± 0.5 h; the intraoperative blood loss was 131.7 ± 121.4 ml. The mean MSTS-93 and AOFAS score was 26.8 and 88.5 respectively. The average plantar flexion, dorsiflexion, varus, and valgus were 32.5, 9.2, 10.8, and 5.8 degree respectively. One patient had delayed postoperative wound healing. There was no leg length discrepancy observed in any patient and good osseointegration was observed on the interface between the bone and talus prosthesis in all subjects. CONCLUSION: The modular structure of the prosthesis developed in this study seems to be convenient for prosthesis implantation and screws distribution. And the combination of solid and porous structure improves the initial stability and promotes bone integration. Therefore, 3D printed custom-made modular talus prosthesis could be an alternative option for talus reconstruction in talus malignant tumor patients.


Assuntos
Neoplasias Ósseas , Impressão Tridimensional , Desenho de Prótese , Tálus , Humanos , Tálus/cirurgia , Tálus/diagnóstico por imagem , Masculino , Adulto , Feminino , Neoplasias Ósseas/cirurgia , Neoplasias Ósseas/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto Jovem , Implantação de Prótese/métodos , Implantação de Prótese/instrumentação , Adolescente , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Osseointegração , Resultado do Tratamento , Amplitude de Movimento Articular , Próteses e Implantes
7.
Int J Nanomedicine ; 19: 4515-4531, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38803996

RESUMO

Introduction: There is an ongoing need for improved healing response and expedited osseointegration on the Ti implants in acetabular fracture sites. To achieve adequate bonding and mechanical stability between the implant surface and the acetabular fracture, a new coating technology must be developed to promote bone integration and prevent bacterial growth. Methods: A cylindrical Ti substrate mounted on a rotating specimen holder was used to implant Ca2+, P2+, and Sr2+ ions at energies of 100 KeV, 75 KeV and 180 KeV, respectively, using a low-energy accelerator to synthesize strontium-substituted hydroxyapatite at varying conditions. Ag2+ ions of energy 100 KeV were subsequently implanted on the as-formed surface at the near-surface region to provide anti-bacterial properties to the as-formed specimen. Results: The properties of the as-formed ion-implanted specimen were compared with the SrHA-Ag synthesized specimens by cathodic deposition and low-temperature high-speed collision technique. The adhesion strength of the ion-implanted specimen was 43 ± 2.3 MPa, which is well above the ASTM standard for Ca-P coating on Ti. Live/dead cell analysis showed higher osteoblast activity on the ion-implanted specimen than the other two. Ag in the SrHA implanted Ti by ion implantation process showed superior antibacterial activity. Discussion: In the ion implantation technique, nano-topography patterned surfaces are not concealed after implantation, and their efficacy in interacting with the osteoblasts is retained. Although all three studies examined the antibacterial effects of Ag2+ ions and the ability to promote bone tissue formation by MC3T3-E1 cells on SrHA-Ag/Ti surfaces, ion implantation techniques demonstrated superior ability. The synthesized specimen can be used as an effective implant in acetabular fracture sites based on their mechanical and biological properties.


Assuntos
Acetábulo , Antibacterianos , Prata , Estrôncio , Titânio , Titânio/química , Titânio/farmacologia , Prata/química , Prata/farmacologia , Estrôncio/química , Estrôncio/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Acetábulo/lesões , Animais , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Osseointegração/efeitos dos fármacos , Camundongos , Propriedades de Superfície , Fraturas Ósseas/terapia , Durapatita/química , Durapatita/farmacologia , Osteoblastos/efeitos dos fármacos , Hidroxiapatitas/química , Hidroxiapatitas/farmacologia , Próteses e Implantes , Íons/química , Íons/farmacologia , Humanos , Linhagem Celular
8.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742501

RESUMO

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Assuntos
Lentes de Contato , Ceratocone , Esclera , Acuidade Visual , Humanos , Ceratocone/cirurgia , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/terapia , Feminino , Masculino , Adulto , Esclera/cirurgia , Implantação de Prótese/métodos , Implantação de Prótese/instrumentação , Resultado do Tratamento , Topografia da Córnea , Próteses e Implantes , Adulto Jovem , Ajuste de Prótese/métodos , Adolescente , Substância Própria/cirurgia
9.
Harefuah ; 163(5): 310-314, 2024 May.
Artigo em Hebraico | MEDLINE | ID: mdl-38734945

RESUMO

INTRODUCTION: Corneal disease is among the leading reversible causes of blindness worldwide. Corneal transplantation is a successful and curative treatment for most of these cases. However, in certain indications it is not amendable for standard corneal transplantation, the only available option to restore functional vision is keratoprosthesis (KPro) implantation. KPros may also offer an alternative to the global shortage of donor corneas, limiting the access to transplantations. However, current KPros face many challenges, including surgical complexity that requires skilled surgeons and vast resources as well as unique surgical and post-operative complications. Although several artificial corneas have been proposed over the years, two implants are mostly used in the clinical setting today. The first, the Boston KPro, consists of a front plate with an optical stem and a back plate snapped together with donor corneal tissue in-between, which is then sutured to the patient's cornea. The second, the Osteo-odonto-keratoprosthesis (OOKP), uses biological tissue of the alveolar bone to support an optical cylinder within the eye. The indications, surgical techniques, and complication profile of the two procedures are different and will be discussed in this review. Extensive research continues to improve the accessibility and technological developments of KPros in the search for a potential breakthrough in the treatment of these difficult cases.


Assuntos
Córnea , Doenças da Córnea , Transplante de Córnea , Próteses e Implantes , Humanos , Doenças da Córnea/cirurgia , Transplante de Córnea/métodos , Córnea/cirurgia , Órgãos Artificiais , Cegueira/etiologia , Complicações Pós-Operatórias
10.
Allergy Asthma Proc ; 45(3): 186-194, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38755777

RESUMO

Background: Concern of metal sensitization in pre- and postsurgical evaluation is growing, with the recent guidelines remaining the criterion standard for consideration of patch testing. Information remains scarce on surgical screening in the groups of patients who reported a history of metal sensitivity versus those with no reported history. Objective: The objective of this study was to assess the utility of patch testing in surgical candidates based on reported metal allergy history. The secondary objective was to evaluate the utility and outcomes in postsurgical patch testing. Methods: Nine hundred and thirty-one patient charts of patients with the diagnosis of "contact dermatitis" who underwent an evaluation at a single allergy clinic site between January 2013 and December 2022 were identified and reviewed as part of a retrospective chart review study. Patients were included in subgroups based on the time of patch testing and history of reported metal allergy. Results: In all, 67 patients underwent patch testing, 10 (14.9%) of whom were surgical candidates without a history of metal sensitivity, 31 (46.2%) of whom were surgical candidates with a history of metal sensitivity, and 26 (38.8%) of whom were postsurgical patients. Twenty-nine (43.3%) of patients had positive patch testing results, with only one (10%) in the presurgical group, 17 (54.8%) in the presurgical with a history of metal sensitivity, and 11 (42.3%) in the postsurgical group. Zero patients in our cohort without metal sensitivity who were undergoing the Nuss procedure had positive reactions on patch testing, whereas two of four (50%) with reported metal sensitivity who were undergoing the Nuss procedure had positive relevant metal reactions. Conclusion: Ambiguity in the utility of patch testing for surgical decision making remains, despite common utilization. Recent guidelines along with coordination of care among the surgeon, allergist, and patient remains the criterion standard of care.


Assuntos
Metais , Testes do Emplastro , Próteses e Implantes , Humanos , Estudos Retrospectivos , Metais/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Próteses e Implantes/efeitos adversos , Adulto , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Idoso , Alérgenos/imunologia
11.
Eur Rev Med Pharmacol Sci ; 28(9): 3391-3402, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38766802

RESUMO

OBJECTIVE: Although pure titanium (PT) and its alloys exhibit excellent mechanical properties, they lack biological activity as implants. The purpose of this study was to improve the biological activity of titanium implants through surface modification. MATERIALS AND METHODS: Titanium was processed into titanium discs, where the titanium discs served as anodes and stainless steel served as cathodes, and a copper- and cobalt-doped porous coating [pure titanium model (PTM)] was prepared on the surface of titanium via plasma electrolytic oxidation. The surface characteristics of the coating were evaluated using field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and profilometry. The corrosion resistance of PTM was evaluated with an electrochemical workstation. The biocompatibility and bioactivity of coated bone marrow mesenchymal stem cells (BMSCs) were evaluated through in vitro cell experiments. RESULTS: A copper- and cobalt-doped porous coating was successfully prepared on the surface of titanium, and the doping of copper and cobalt did not change the surface topography of the coating. The porous coating increased the surface roughness of titanium and improved its resistance to corrosion. In addition, the porous coating doped with copper and cobalt promoted the adhesion and spreading of BMSCs. CONCLUSIONS: A porous coating doped with copper and cobalt was prepared on the surface of titanium through plasma electrolytic oxidation. The coating not only improved the roughness and corrosion resistance of titanium but also exhibited good biological activity.


Assuntos
Materiais Revestidos Biocompatíveis , Cobalto , Cobre , Células-Tronco Mesenquimais , Propriedades de Superfície , Titânio , Titânio/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Cobre/química , Porosidade , Cobalto/química , Animais , Corrosão , Teste de Materiais , Células Cultivadas , Próteses e Implantes
12.
ACS Appl Mater Interfaces ; 16(19): 24421-24430, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38690964

RESUMO

Periprosthetic infections caused by Staphylococcus aureus (S. aureus) pose unique challenges in orthopedic surgeries, in part due to the bacterium's capacity to invade surrounding bone tissues besides forming recalcitrant biofilms on implant surfaces. We previously developed prophylactic implant coatings for the on-demand release of vancomycin, triggered by the cleavage of an oligonucleotide (Oligo) linker by micrococcal nuclease (MN) secreted by the Gram-positive bacterium, to eradicate S. aureus surrounding the implant in vitro and in vivo. Building upon this coating platform, here we explore the feasibility of extending the on-demand release to ampicillin, a broad-spectrum aminopenicillin ß-lactam antibiotic that is more effective than vancomycin in killing Gram-negative bacteria that may accompany S. aureus infections. The amino group of ampicillin was successfully conjugated to the carboxyl end of an MN-sensitive Oligo covalently integrated in a polymethacrylate hydrogel coating applied to titanium alloy pins. The resultant Oligo-Ampicillin hydrogel coating released the ß-lactam in the presence of S. aureus and successfully cleared nearby S. aureus in vitro. When the Oligo-Ampicillin-coated pin was delivered to a rat femoral canal inoculated with 1000 cfu S. aureus, it prevented periprosthetic infection with timely on-demand drug release. The clearance of the bacteria from the pin surface as well as surrounding tissue persisted over 3 months, with no local or systemic toxicity observed with the coating. The negatively charged Oligo fragment attached to ampicillin upon cleavage from the coating did diminish the antibiotic's potency against S. aureus and Escherichia coli (E. coli) to varying degrees, likely due to electrostatic repulsion by the anionic surfaces of the bacteria. Although the on-demand release of the ß-lactam led to adequate killing of S. aureus but not E. coli in the presence of a mixture of the bacteria, strong inhibition of the colonization of the remaining E. coli on hydrogel coating was observed. These findings will inspire considerations of alternative broad-spectrum antibiotics, optimized drug conjugation, and Oligo linker engineering for more effective protection against polymicrobial periprosthetic infections.


Assuntos
Ampicilina , Antibacterianos , Materiais Revestidos Biocompatíveis , Infecções Relacionadas à Prótese , Infecções Estafilocócicas , Staphylococcus aureus , Animais , Staphylococcus aureus/efeitos dos fármacos , Ampicilina/química , Ampicilina/farmacologia , Ratos , Antibacterianos/química , Antibacterianos/farmacologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Infecções Estafilocócicas/prevenção & controle , Infecções Estafilocócicas/tratamento farmacológico , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/microbiologia , Ratos Sprague-Dawley , Testes de Sensibilidade Microbiana , Liberação Controlada de Fármacos , Próteses e Implantes
13.
J Orthop Surg Res ; 19(1): 299, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755635

RESUMO

BACKGROUND: This study aims to evaluate the optimal ratio of synthetic bone graft (SBG) material and platelet rich fibrin (PRF) mixed in a metal 3D-printed implant to enhance bone regeneration. METHODS: Specialized titanium hollow implants (5 mm in diameter and 6 mm in height for rabbit; 6 mm in diameter and 5 mm in height for pig) were designed and manufactured using 3D printing technology. The implants were divided into three groups and filled with different bone graft combinations, namely (1) SBG alone; (2) PRF to SBG in 1:1 ratio; (3) PRF to SBG in 2:1 ratio. These three groups were replicated tightly into each bone defect in distal femurs of rabbits (nine implants, n = 3) and femoral shafts of pigs (fifteen implants, n = 5). Animal tissue sections were obtained after euthanasia at the 8th postoperative week. The rabbit specimens were stained with analine blue, while the pig specimens were stained with Masson-Goldner's trichrome stain to perform histologically examination. All titanium hollow implants were well anchored, except in fracture specimens (three in the rabbit and one fracture in the pig). RESULT: Rabbit specimens under analine blue staining showed that collagen tissue increased by about 20% and 40% in the 1:1 ratio group and the 2:1 ratio group, respectively. Masson-Goldner's trichrome stain results showed that new bone growth increased by 32% in the 1:1 ratio PRF to SBG, while - 8% in the 2:1 ratio group. CONCLUSION: This study demonstrated that placing a 1:1 ratio combination of PRF and SBG in a stabilized titanium 3D printed implant resulted in an optimal increase in bone growth.


Assuntos
Regeneração Óssea , Fibrina Rica em Plaquetas , Impressão Tridimensional , Titânio , Animais , Coelhos , Regeneração Óssea/efeitos dos fármacos , Regeneração Óssea/fisiologia , Suínos , Fêmur/cirurgia , Substitutos Ósseos , Transplante Ósseo/métodos , Próteses e Implantes
14.
Med Eng Phys ; 128: 104178, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38789215

RESUMO

Several finite element (FE) studies reported performances of various lumbar fusion surgical approaches. However, comparative studies on the performance of Open Laminectomy plus Posterolateral Fusion (OL-PLF) and Open Laminectomy plus Transforaminal Interbody Fusion (OL-TLIF) surgical approaches are rare. In the current FE study, the variation in ranges of motions (ROM), stress-strain distributions in an implanted functional spinal unit (FSU) and caudal adjacent soft structures between OL-PLF and OL-TLIF virtual models were investigated. The implanted lumbar spine FE models were developed from subject-specific computed tomography images of an intact spine and solved for physiological loadings such as compression, flexion, extension and lateral bending. Reductions in the ROMs of L1-L5 (49 % to 59 %) and L3-L4 implanted FSUs (91 % to 96 %) were observed for both models. Under all the loading cases, the maximum von Mises strain observed in the implanted segment of both models exceeds the mean compressive yield strain for the vertebra. The maximum von Mises stress and strain observed on the caudal adjacent soft structures of both the implanted models are at least 22 % higher than the natural spine model. The findings indicate the risk of failure in the implanted FSUs and higher chances of adjacent segment degeneration for both models.


Assuntos
Análise de Elementos Finitos , Laminectomia , Vértebras Lombares , Fusão Vertebral , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Humanos , Estresse Mecânico , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Masculino , Próteses e Implantes
16.
Vestn Oftalmol ; 140(2. Vyp. 2): 166-171, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739147

RESUMO

Loading of the upper eyelid with palpebral implants made of noble metals is the modern standard of surgical treatment for paralytic lagophthalmos, and is aimed at increasing the mobility of the upper eyelid and normalizing involuntary blinking movements. This review presents the results of morphological studies, including immunohistochemical studies, reflecting the features of biointegration of palpebral implants in uncomplicated and complicated course of the postoperative period, and describes the modern understanding of the causes and immunopathological processes underlying the development of nonspecific inflammatory response, which is one of the most serious complications that often becomes an indication for implant removal.


Assuntos
Pálpebras , Humanos , Pálpebras/cirurgia , Doenças Palpebrais/cirurgia , Metais , Próteses e Implantes , Blefaroplastia/métodos , Desenho de Prótese
18.
Front Cell Infect Microbiol ; 14: 1398461, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38803573

RESUMO

Addressing the existing problem in the microbiological diagnosis of infections associated with implants and the current debate about the real power of precision of sonicated fluid culture (SFC), the objective of this review is to describe the methodology and analyze and compare the results obtained in current studies on the subject. Furthermore, the present study also discusses and suggests the best parameters for performing sonication. A search was carried out for recent studies in the literature (2019-2023) that addressed this research topic. As a result, different sonication protocols were adopted in the studies analyzed, as expected, and consequently, there was significant variability between the results obtained regarding the sensitivity and specificity of the technique in relation to the traditional culture method (periprosthetic tissue culture - PTC). Coagulase-negative Staphylococcus (CoNS) and Staphylococcus aureus were identified as the main etiological agents by SFC and PTC, with SFC being important for the identification of pathogens of low virulence that are difficult to detect. Compared to chemical biofilm displacement methods, EDTA and DTT, SFC also produced variable results. In this context, this review provided an overview of the most current scenarios on the topic and theoretical support to improve sonication performance, especially with regard to sensitivity and specificity, by scoring the best parameters from various aspects, including sample collection, storage conditions, cultivation methods, microorganism identification techniques (both phenotypic and molecular) and the cutoff point for colony forming unit (CFU) counts. This study demonstrated the need for standardization of the technique and provided a theoretical basis for a sonication protocol that aims to achieve the highest levels of sensitivity and specificity for the reliable microbiological diagnosis of infections associated with implants and prosthetic devices, such as prosthetic joint infections (PJIs). However, practical application and additional complementary studies are still needed.


Assuntos
Infecções Relacionadas à Prótese , Sonicação , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Humanos , Sensibilidade e Especificidade , Biofilmes/crescimento & desenvolvimento , Técnicas Microbiológicas/métodos , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Técnicas Bacteriológicas/métodos , Próteses e Implantes/microbiologia
20.
Int J Mol Sci ; 25(10)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38791362

RESUMO

In the field of biomaterials for prosthetic reconstructive surgery, there is the lack of advanced innovative methods to investigate the potentialities of smart biomaterials before in vivo tests. Despite the complex osteointegration process being difficult to recreate in vitro, this study proposes an advanced in vitro tissue culture model of osteointegration using human bone. Cubic samples of trabecular bone were harvested, as waste material, from hip arthroplasty; inner cylindrical defects were created and assigned to the following groups: (1) empty defects (CTRneg); (2) defects implanted with a cytotoxic copper pin (CTRpos); (3) defects implanted with standard titanium pins (Ti). Tissues were dynamically cultured in mini rotating bioreactors and assessed weekly for viability and sterility. After 8 weeks, immunoenzymatic, microtomographic, histological, and histomorphometric analyses were performed. The model was able to simulate the effects of implantation of the materials, showing a drop in viability in CTR+, while Ti appears to have a trophic effect on bone. MicroCT and a histological analysis supported the results, with signs of matrix and bone deposition at the Ti implant site. Data suggest the reliability of the tested model in recreating the osteointegration process in vitro with the aim of reducing and refining in vivo preclinical models.


Assuntos
Osseointegração , Técnicas de Cultura de Tecidos , Titânio , Humanos , Técnicas de Cultura de Tecidos/métodos , Microtomografia por Raio-X , Osso e Ossos/citologia , Materiais Biocompatíveis , Próteses e Implantes , Osso Esponjoso/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...