Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50.401
Filtrar
2.
Harefuah ; 163(5): 310-314, 2024 May.
Artigo em Hebraico | MEDLINE | ID: mdl-38734945

RESUMO

INTRODUCTION: Corneal disease is among the leading reversible causes of blindness worldwide. Corneal transplantation is a successful and curative treatment for most of these cases. However, in certain indications it is not amendable for standard corneal transplantation, the only available option to restore functional vision is keratoprosthesis (KPro) implantation. KPros may also offer an alternative to the global shortage of donor corneas, limiting the access to transplantations. However, current KPros face many challenges, including surgical complexity that requires skilled surgeons and vast resources as well as unique surgical and post-operative complications. Although several artificial corneas have been proposed over the years, two implants are mostly used in the clinical setting today. The first, the Boston KPro, consists of a front plate with an optical stem and a back plate snapped together with donor corneal tissue in-between, which is then sutured to the patient's cornea. The second, the Osteo-odonto-keratoprosthesis (OOKP), uses biological tissue of the alveolar bone to support an optical cylinder within the eye. The indications, surgical techniques, and complication profile of the two procedures are different and will be discussed in this review. Extensive research continues to improve the accessibility and technological developments of KPros in the search for a potential breakthrough in the treatment of these difficult cases.


Assuntos
Córnea , Doenças da Córnea , Transplante de Córnea , Próteses e Implantes , Humanos , Doenças da Córnea/cirurgia , Transplante de Córnea/métodos , Córnea/cirurgia , Órgãos Artificiais , Cegueira/etiologia , Complicações Pós-Operatórias
3.
ACS Nano ; 18(20): 13196-13213, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38717096

RESUMO

There is an increasingly growing demand to balance tissue repair guidance and opportunistic infection (OI) inhibition in clinical implant surgery. Herein, we developed a nanoadjuvant for all-stage tissue repair guidance and biofilm-responsive OI eradication via in situ incorporating Cobaltiprotoporphyrin (CoPP) into Prussian blue (PB) to prepare PB-CoPP nanozymes (PCZs). Released CoPP possesses a pro-efferocytosis effect for eliminating apoptotic and progressing necrotic cells in tissue trauma, thus preventing secondary inflammation. Once OIs occur, PCZs with switchable nanocatalytic capacity can achieve bidirectional pyroptosis regulation. Once reaching the acidic biofilm microenvironment, PCZs possess peroxidase (POD)-like activity that can generate reactive oxygen species (ROS) to eradicate bacterial biofilms, especially when synergized with the photothermal effect. Furthermore, generated ROS can promote macrophage pyroptosis to secrete inflammatory cytokines and antimicrobial proteins for biofilm eradication in vivo. After eradicating the biofilm, PCZs possess catalase (CAT)-like activity in a neutral environment, which can scavenge ROS and inhibit macrophage pyroptosis, thereby improving the inflammatory microenvironment. Briefly, PCZs as nanoadjuvants feature the capability of all-stage tissue repair guidance and biofilm-responsive OI inhibition that can be routinely performed in all implant surgeries, providing a wide range of application prospects and commercial translational value.


Assuntos
Biofilmes , Piroptose , Biofilmes/efeitos dos fármacos , Piroptose/efeitos dos fármacos , Animais , Camundongos , Espécies Reativas de Oxigênio/metabolismo , Ferrocianetos/química , Ferrocianetos/farmacologia , Próteses e Implantes , Macrófagos/metabolismo , Macrófagos/efeitos dos fármacos , Antibacterianos/farmacologia , Antibacterianos/química , Cicatrização/efeitos dos fármacos , Humanos , Eferocitose
4.
Artigo em Inglês | MEDLINE | ID: mdl-38716831

RESUMO

BACKGROUND: Patients with persistent air leak (PAL) pose a therapeutic challenge to physicians, with prolonged hospital stays and high morbidity. There is little evidence on the efficacy and safety of bronchial valves (BV) for PAL. METHODS: We systematically searched the PubMed and Embase databases to identify studies evaluating the efficacy and safety of BV for PAL. We calculated the success rate (complete resolution of air leak or removal of intercostal chest drain after bronchial valve placement and requiring no further procedures) of BV for PAL in individual studies. We pooled the data using a random-effects model and examined the factors influencing the success rate using multivariable meta-regression. RESULTS: We analyzed 28 observational studies (2472 participants). The pooled success rate of bronchial valves in PAL was 82% (95% confidence intervals, 75 to 88; 95% prediction intervals, 64 to 92). We found a higher success rate in studies using intrabronchial valves versus endobronchial valves (84% vs. 72%) and in studies with more than 50 subjects (93% vs. 77%). However, none of the factors influenced the success rate of multivariable meta-regression. The overall complication rate was 9.1% (48/527). Granulation tissue was the most common complication reported followed by valve migration or expectoration and hypoxemia. CONCLUSION: Bronchial valves are an effective and safe option for treating PAL. However, the analysis is limited by the availability of only observational data.


Assuntos
Pneumotórax , Humanos , Brônquios , Broncoscopia/métodos , Broncoscopia/efeitos adversos , Tubos Torácicos/efeitos adversos , Estudos Observacionais como Assunto , Pneumotórax/etiologia , Complicações Pós-Operatórias/epidemiologia , Próteses e Implantes/efeitos adversos , Resultado do Tratamento
5.
Artigo em Inglês | MEDLINE | ID: mdl-38723798

RESUMO

Wearable and implantable sensing of biomechanical signals such as pressure, strain, shear, and vibration can enable a multitude of human-integrated applications, including on-skin monitoring of vital signs, motion tracking, monitoring of internal organ condition, restoration of lost/impaired mechanoreception, among many others. The mechanical conformability of such sensors to the human skin and tissue is critical to enhancing their biocompatibility and sensing accuracy. As such, in the recent decade, significant efforts have been made in the development of soft mechanical sensors. To satisfy the requirements of different wearable and implantable applications, such sensors have been imparted with various additional properties to make them better suited for the varied contexts of human-integrated applications. In this review, focusing on the four major types of soft mechanical sensors for pressure, strain, shear, and vibration, we discussed the recent material and device design innovations for achieving several important properties, including flexibility and stretchability, bioresorbability and biodegradability, self-healing properties, breathability, transparency, wireless communication capabilities, and high-density integration. We then went on to discuss the current research state of the use of such novel soft mechanical sensors in wearable and implantable applications, based on which future research needs were further discussed. This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > Diagnostic Nanodevices Implantable Materials and Surgical Technologies > Nanomaterials and Implants.


Assuntos
Próteses e Implantes , Dispositivos Eletrônicos Vestíveis , Humanos , Desenho de Equipamento , Técnicas Biossensoriais/instrumentação , Monitorização Fisiológica/instrumentação
6.
Int J Mol Sci ; 25(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38731871

RESUMO

Implanted medical devices are widely used across various medical specialties for numerous applications, ranging from cardiovascular supports to orthopedic prostheses and cosmetic enhancements. However, recent observations have raised concerns about the potential of these implants to induce malignancies in the tissues surrounding them. There have been several case reports documenting the occurrence of cancers adjacent to these devices, prompting a closer examination of their safety. This review delves into the epidemiology, clinical presentations, pathological findings, and hypothesized mechanisms of carcinogenesis related to implanted devices. It also explores how the surgical domain and the intrinsic properties and biocompatibility of the implants might influence the development of these rare but serious malignancies. Understanding these associations is crucial for assessing the risks associated with the use of medical implants, and for developing strategies to mitigate potential adverse outcomes.


Assuntos
Materiais Biocompatíveis , Neoplasias , Próteses e Implantes , Humanos , Materiais Biocompatíveis/efeitos adversos , Próteses e Implantes/efeitos adversos , Neoplasias/etiologia , Animais
7.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742501

RESUMO

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Assuntos
Lentes de Contato , Ceratocone , Esclera , Acuidade Visual , Humanos , Ceratocone/cirurgia , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/terapia , Feminino , Masculino , Adulto , Esclera/cirurgia , Implantação de Prótese/métodos , Implantação de Prótese/instrumentação , Resultado do Tratamento , Topografia da Córnea , Próteses e Implantes , Adulto Jovem , Ajuste de Prótese/métodos , Adolescente , Substância Própria/cirurgia
8.
Nat Commun ; 15(1): 4017, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740759

RESUMO

Ultrasound-driven bioelectronics could offer a wireless scheme with sustainable power supply; however, current ultrasound implantable systems present critical challenges in biocompatibility and harvesting performance related to lead/lead-free piezoelectric materials and devices. Here, we report a lead-free dual-frequency ultrasound implants for wireless, biphasic deep brain stimulation, which integrates two developed lead-free sandwich porous 1-3-type piezoelectric composite elements with enhanced harvesting performance in a flexible printed circuit board. The implant is ultrasonically powered through a portable external dual-frequency transducer and generates programmable biphasic stimulus pulses in clinically relevant frequencies. Furthermore, we demonstrate ultrasound-driven implants for long-term biosafety therapy in deep brain stimulation through an epileptic rodent model. With biocompatibility and improved electrical performance, the lead-free materials and devices presented here could provide a promising platform for developing implantable ultrasonic electronics in the future.


Assuntos
Estimulação Encefálica Profunda , Tecnologia sem Fio , Estimulação Encefálica Profunda/instrumentação , Estimulação Encefálica Profunda/métodos , Animais , Tecnologia sem Fio/instrumentação , Ratos , Eletrodos Implantados , Epilepsia/terapia , Masculino , Próteses e Implantes , Ratos Sprague-Dawley , Transdutores , Desenho de Equipamento , Ondas Ultrassônicas
9.
J Orthop Surg Res ; 19(1): 273, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698477

RESUMO

BACKGROUND: Talar malignant tumor is extremely rare. Currently, there are several alternative management options for talus malignant tumor including below-knee amputation, tibio-calcaneal arthrodesis, and homogenous bone transplant while their shortcomings limited the clinical application. Three-dimensional (3D) printed total talus prosthesis in talus lesion was reported as a useful method to reconstruct talus, however, most researches are case reports and its clinical effect remains unclear. Therefore, the current study was to explore the application of 3D printed custom-made modular prosthesis in talus malignant tumor. METHODS: We retrospectively analyzed the patients who received the 3D printed custom-made modular prosthesis treatment due to talus malignant tumor in our hospital from February 2016 to December 2021. The patient's clinical data such as oncology outcome, operation time, and volume of blood loss were recorded. The limb function was evaluated with the Musculoskeletal Tumor Society 93 (MSTS-93) score, The American Orthopedic Foot and Ankle Society (AOFAS) score; the ankle joint ranges of motion as well as the leg length discrepancy were evaluated. Plain radiography and Tomosynthesis-Shimadzu Metal Artefact Reduction Technology (T-SMART) were used to evaluate the position of prosthesis and the osseointegration. Postoperative complications were recorded. RESULTS: The average patients' age and the follow-up period were respectively 31.5 ± 13.1 years; and 54.8 months (range 26-72). The medium operation time was 2.4 ± 0.5 h; the intraoperative blood loss was 131.7 ± 121.4 ml. The mean MSTS-93 and AOFAS score was 26.8 and 88.5 respectively. The average plantar flexion, dorsiflexion, varus, and valgus were 32.5, 9.2, 10.8, and 5.8 degree respectively. One patient had delayed postoperative wound healing. There was no leg length discrepancy observed in any patient and good osseointegration was observed on the interface between the bone and talus prosthesis in all subjects. CONCLUSION: The modular structure of the prosthesis developed in this study seems to be convenient for prosthesis implantation and screws distribution. And the combination of solid and porous structure improves the initial stability and promotes bone integration. Therefore, 3D printed custom-made modular talus prosthesis could be an alternative option for talus reconstruction in talus malignant tumor patients.


Assuntos
Neoplasias Ósseas , Impressão Tridimensional , Desenho de Prótese , Tálus , Humanos , Tálus/cirurgia , Tálus/diagnóstico por imagem , Masculino , Adulto , Feminino , Neoplasias Ósseas/cirurgia , Neoplasias Ósseas/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto Jovem , Implantação de Prótese/métodos , Implantação de Prótese/instrumentação , Adolescente , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Osseointegração , Resultado do Tratamento , Amplitude de Movimento Articular , Próteses e Implantes
10.
Int J Mol Sci ; 25(10)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38791362

RESUMO

In the field of biomaterials for prosthetic reconstructive surgery, there is the lack of advanced innovative methods to investigate the potentialities of smart biomaterials before in vivo tests. Despite the complex osteointegration process being difficult to recreate in vitro, this study proposes an advanced in vitro tissue culture model of osteointegration using human bone. Cubic samples of trabecular bone were harvested, as waste material, from hip arthroplasty; inner cylindrical defects were created and assigned to the following groups: (1) empty defects (CTRneg); (2) defects implanted with a cytotoxic copper pin (CTRpos); (3) defects implanted with standard titanium pins (Ti). Tissues were dynamically cultured in mini rotating bioreactors and assessed weekly for viability and sterility. After 8 weeks, immunoenzymatic, microtomographic, histological, and histomorphometric analyses were performed. The model was able to simulate the effects of implantation of the materials, showing a drop in viability in CTR+, while Ti appears to have a trophic effect on bone. MicroCT and a histological analysis supported the results, with signs of matrix and bone deposition at the Ti implant site. Data suggest the reliability of the tested model in recreating the osteointegration process in vitro with the aim of reducing and refining in vivo preclinical models.


Assuntos
Osseointegração , Técnicas de Cultura de Tecidos , Titânio , Humanos , Técnicas de Cultura de Tecidos/métodos , Microtomografia por Raio-X , Osso e Ossos/citologia , Materiais Biocompatíveis , Próteses e Implantes , Osso Esponjoso/citologia
11.
Analyst ; 149(11): 3085-3096, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38712737

RESUMO

In the orthopaedic surgery field, the use of medical implants to treat a patient's bone fracture is nowadays a common practice, nevertheless, it is associated with possible cases of infection. The consequent hardware infection can lead to implant failure and systemic infections, with prolonged hospitalization, time-consuming rehabilitation treatments, and extended antibiotic therapy. Hardware infections are strictly related to bacterial adhesion to the implant, leading to infection occurrence and consequent pH decreasing from physiological level to acid pH. Here, we demonstrate the new strategy to use an orthopaedic implant functionalized with iridium oxide film as the working electrode for the potentiometric monitoring of pH in hardware infection diagnosis. A functional investigation was focused on selecting the implant material, namely titanium, titanium alloy, and stainless steel, and the component, namely screws and implants. After selecting the titanium-based implant as the working electrode and a silver wire as the reference electrode in the final configuration of the smart sensing orthopaedic implant, a calibration curve was performed in standard solutions. An equation equal to y = (0.76 ± 0.02) - (0.068 ± 0.002) x, R2 = 0.996, was obtained in the pH range of 4-8. Subsequently, hysteresis, interference, matrix effect, recovery study, and storage stability were investigated to test the overall performance of the sensing device, demonstrating the tremendous potential of electrochemical sensors to deliver the next generation of smart orthopaedic implants.


Assuntos
Próteses e Implantes , Concentração de Íons de Hidrogênio , Humanos , Irídio/química , Eletrodos , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Titânio/química , Infecções Relacionadas à Prótese/diagnóstico , Potenciometria/instrumentação , Potenciometria/métodos
12.
J Med Syst ; 48(1): 55, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780820

RESUMO

Designing implants for large and complex cranial defects is a challenging task, even for professional designers. Current efforts on automating the design process focused mainly on convolutional neural networks (CNN), which have produced state-of-the-art results on reconstructing synthetic defects. However, existing CNN-based methods have been difficult to translate to clinical practice in cranioplasty, as their performance on large and complex cranial defects remains unsatisfactory. In this paper, we present a statistical shape model (SSM) built directly on the segmentation masks of the skulls represented as binary voxel occupancy grids and evaluate it on several cranial implant design datasets. Results show that, while CNN-based approaches outperform the SSM on synthetic defects, they are inferior to SSM when it comes to large, complex and real-world defects. Experienced neurosurgeons evaluate the implants generated by the SSM to be feasible for clinical use after minor manual corrections. Datasets and the SSM model are publicly available at https://github.com/Jianningli/ssm .


Assuntos
Redes Neurais de Computação , Crânio , Humanos , Crânio/cirurgia , Crânio/anatomia & histologia , Crânio/diagnóstico por imagem , Modelos Estatísticos , Processamento de Imagem Assistida por Computador/métodos , Procedimentos de Cirurgia Plástica/métodos , Próteses e Implantes
13.
Med Eng Phys ; 128: 104178, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38789215

RESUMO

Several finite element (FE) studies reported performances of various lumbar fusion surgical approaches. However, comparative studies on the performance of Open Laminectomy plus Posterolateral Fusion (OL-PLF) and Open Laminectomy plus Transforaminal Interbody Fusion (OL-TLIF) surgical approaches are rare. In the current FE study, the variation in ranges of motions (ROM), stress-strain distributions in an implanted functional spinal unit (FSU) and caudal adjacent soft structures between OL-PLF and OL-TLIF virtual models were investigated. The implanted lumbar spine FE models were developed from subject-specific computed tomography images of an intact spine and solved for physiological loadings such as compression, flexion, extension and lateral bending. Reductions in the ROMs of L1-L5 (49 % to 59 %) and L3-L4 implanted FSUs (91 % to 96 %) were observed for both models. Under all the loading cases, the maximum von Mises strain observed in the implanted segment of both models exceeds the mean compressive yield strain for the vertebra. The maximum von Mises stress and strain observed on the caudal adjacent soft structures of both the implanted models are at least 22 % higher than the natural spine model. The findings indicate the risk of failure in the implanted FSUs and higher chances of adjacent segment degeneration for both models.


Assuntos
Análise de Elementos Finitos , Laminectomia , Vértebras Lombares , Fusão Vertebral , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Humanos , Estresse Mecânico , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Masculino , Próteses e Implantes
14.
Vestn Oftalmol ; 140(2. Vyp. 2): 166-171, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739147

RESUMO

Loading of the upper eyelid with palpebral implants made of noble metals is the modern standard of surgical treatment for paralytic lagophthalmos, and is aimed at increasing the mobility of the upper eyelid and normalizing involuntary blinking movements. This review presents the results of morphological studies, including immunohistochemical studies, reflecting the features of biointegration of palpebral implants in uncomplicated and complicated course of the postoperative period, and describes the modern understanding of the causes and immunopathological processes underlying the development of nonspecific inflammatory response, which is one of the most serious complications that often becomes an indication for implant removal.


Assuntos
Pálpebras , Humanos , Pálpebras/cirurgia , Doenças Palpebrais/cirurgia , Metais , Próteses e Implantes , Blefaroplastia/métodos , Desenho de Prótese
15.
Medicine (Baltimore) ; 103(18): e37932, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38701315

RESUMO

Angiosarcomas are rare and highly malignant soft tissue sarcomas originating from endothelial cells lining the lymphatic or vascular system. While they predominantly emerge from (sub)cutaneous regions, occurrences have been reported throughout the body. The etiology of angiosarcoma remains elusive in most clinical cases. Nevertheless, several prognosis risk factors play a pivotal role, including chronic lymphedema, therapeutic irradiation, environmental carcinogens, familial syndromes, and the presence of foreign materials like metallic objects and biomedical implants. Despite evidence implicating retained foreign material in angiosarcoma development, understanding its prognosis and pathogenesis remains limited. The pathogenesis of angiosarcoma appears to involve a complex interplay of chronic inflammation, tissue remodeling, and genetic factors that create a conducive microenvironment for malignant transformation. Management of these sarcomas remains challenging due to their infiltrative nature owing to the high chance of metastasis and local recurrence. The primary treatment modalities currently include surgery, radiotherapy, and chemotherapy, but recent advances in targeted immunotherapy and gene therapy hold promise for more effective approaches. This comprehensive review delves into the potential etiological and pathogenic roles of foreign materials, such as metallic objects, biomedical implants, and biomaterials, in the development of angiosarcoma. Further research into the underlying molecular mechanisms could provide valuable insights for tailored management and developing novel targeted therapeutic strategies.


Assuntos
Corpos Estranhos , Hemangiossarcoma , Próteses e Implantes , Humanos , Hemangiossarcoma/terapia , Hemangiossarcoma/etiologia , Hemangiossarcoma/patologia , Corpos Estranhos/complicações , Corpos Estranhos/terapia , Próteses e Implantes/efeitos adversos , Fatores de Risco
16.
Biomed Mater ; 19(4)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38740037

RESUMO

The purpose of this study was to construct a rutin-controlled release system on the surface of Ti substrates and investigate its effects on osteogenesis and osseointegration on the surface of implants. The base layer, polyethylenimine (PEI), was immobilised on a titanium substrate. Then, hyaluronic acid (HA)/chitosan (CS)-rutin (RT) multilayer films were assembled on the PEI using layer-by-layer (LBL) assembly technology. We used scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy and contact angle measurements to examine all Ti samples. The drug release test of rutin was also carried out to detect the slow-release performance. The osteogenic abilities of the samples were evaluated by experiments on an osteoporosis rat model and MC3T3-E1 cells. The results (SEM, FTIR and contact angle measurements) all confirmed that the PEI substrate layer and HA/CS-RT multilayer film were effectively immobilised on titanium. The drug release test revealed that a rutin controlled release mechanism had been successfully established. Furthermore, thein vitrodata revealed that osteoblasts on the coated titanium matrix had greater adhesion, proliferation, and differentiation capacity than the osteoblasts on the pure titanium surface. When MC3T3-E1 cells were exposed to H2O2-induced oxidative stressin vitro, cell-based tests revealed great tolerance and increased osteogenic potential on HA/CS-RT substrates. We also found that the HA/CS-RT coating significantly increased the new bone mass around the implant. The LBL-deposited HA/CS-RT multilayer coating on the titanium base surface established an excellent rutin-controlled release system, which significantly improved osseointegration and promoted osteogenesis under oxidative stress conditions, suggesting a new implant therapy strategy for patients with osteoporosis.


Assuntos
Materiais Revestidos Biocompatíveis , Ácido Hialurônico , Osseointegração , Osteoblastos , Osteogênese , Osteoporose , Próteses e Implantes , Rutina , Propriedades de Superfície , Titânio , Animais , Titânio/química , Rutina/química , Rutina/farmacologia , Osteogênese/efeitos dos fármacos , Ratos , Osteoporose/tratamento farmacológico , Camundongos , Osteoblastos/efeitos dos fármacos , Osteoblastos/citologia , Osteoblastos/metabolismo , Osseointegração/efeitos dos fármacos , Ácido Hialurônico/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Oxirredução , Quitosana/química , Feminino , Ratos Sprague-Dawley , Adesão Celular/efeitos dos fármacos , Espectroscopia de Infravermelho com Transformada de Fourier , Diferenciação Celular/efeitos dos fármacos , Microscopia Eletrônica de Varredura , Proliferação de Células/efeitos dos fármacos , Polietilenoimina/química , Células 3T3 , Estresse Oxidativo/efeitos dos fármacos , Nanopartículas em Multicamadas
17.
Eur Rev Med Pharmacol Sci ; 28(9): 3391-3402, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38766802

RESUMO

OBJECTIVE: Although pure titanium (PT) and its alloys exhibit excellent mechanical properties, they lack biological activity as implants. The purpose of this study was to improve the biological activity of titanium implants through surface modification. MATERIALS AND METHODS: Titanium was processed into titanium discs, where the titanium discs served as anodes and stainless steel served as cathodes, and a copper- and cobalt-doped porous coating [pure titanium model (PTM)] was prepared on the surface of titanium via plasma electrolytic oxidation. The surface characteristics of the coating were evaluated using field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and profilometry. The corrosion resistance of PTM was evaluated with an electrochemical workstation. The biocompatibility and bioactivity of coated bone marrow mesenchymal stem cells (BMSCs) were evaluated through in vitro cell experiments. RESULTS: A copper- and cobalt-doped porous coating was successfully prepared on the surface of titanium, and the doping of copper and cobalt did not change the surface topography of the coating. The porous coating increased the surface roughness of titanium and improved its resistance to corrosion. In addition, the porous coating doped with copper and cobalt promoted the adhesion and spreading of BMSCs. CONCLUSIONS: A porous coating doped with copper and cobalt was prepared on the surface of titanium through plasma electrolytic oxidation. The coating not only improved the roughness and corrosion resistance of titanium but also exhibited good biological activity.


Assuntos
Materiais Revestidos Biocompatíveis , Cobalto , Cobre , Células-Tronco Mesenquimais , Propriedades de Superfície , Titânio , Titânio/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Cobre/química , Porosidade , Cobalto/química , Animais , Corrosão , Teste de Materiais , Células Cultivadas , Próteses e Implantes
18.
ACS Appl Mater Interfaces ; 16(19): 24421-24430, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38690964

RESUMO

Periprosthetic infections caused by Staphylococcus aureus (S. aureus) pose unique challenges in orthopedic surgeries, in part due to the bacterium's capacity to invade surrounding bone tissues besides forming recalcitrant biofilms on implant surfaces. We previously developed prophylactic implant coatings for the on-demand release of vancomycin, triggered by the cleavage of an oligonucleotide (Oligo) linker by micrococcal nuclease (MN) secreted by the Gram-positive bacterium, to eradicate S. aureus surrounding the implant in vitro and in vivo. Building upon this coating platform, here we explore the feasibility of extending the on-demand release to ampicillin, a broad-spectrum aminopenicillin ß-lactam antibiotic that is more effective than vancomycin in killing Gram-negative bacteria that may accompany S. aureus infections. The amino group of ampicillin was successfully conjugated to the carboxyl end of an MN-sensitive Oligo covalently integrated in a polymethacrylate hydrogel coating applied to titanium alloy pins. The resultant Oligo-Ampicillin hydrogel coating released the ß-lactam in the presence of S. aureus and successfully cleared nearby S. aureus in vitro. When the Oligo-Ampicillin-coated pin was delivered to a rat femoral canal inoculated with 1000 cfu S. aureus, it prevented periprosthetic infection with timely on-demand drug release. The clearance of the bacteria from the pin surface as well as surrounding tissue persisted over 3 months, with no local or systemic toxicity observed with the coating. The negatively charged Oligo fragment attached to ampicillin upon cleavage from the coating did diminish the antibiotic's potency against S. aureus and Escherichia coli (E. coli) to varying degrees, likely due to electrostatic repulsion by the anionic surfaces of the bacteria. Although the on-demand release of the ß-lactam led to adequate killing of S. aureus but not E. coli in the presence of a mixture of the bacteria, strong inhibition of the colonization of the remaining E. coli on hydrogel coating was observed. These findings will inspire considerations of alternative broad-spectrum antibiotics, optimized drug conjugation, and Oligo linker engineering for more effective protection against polymicrobial periprosthetic infections.


Assuntos
Ampicilina , Antibacterianos , Materiais Revestidos Biocompatíveis , Infecções Relacionadas à Prótese , Infecções Estafilocócicas , Staphylococcus aureus , Animais , Staphylococcus aureus/efeitos dos fármacos , Ampicilina/química , Ampicilina/farmacologia , Ratos , Antibacterianos/química , Antibacterianos/farmacologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Infecções Estafilocócicas/prevenção & controle , Infecções Estafilocócicas/tratamento farmacológico , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/microbiologia , Ratos Sprague-Dawley , Testes de Sensibilidade Microbiana , Liberação Controlada de Fármacos , Próteses e Implantes
19.
J Orthop Surg Res ; 19(1): 299, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755635

RESUMO

BACKGROUND: This study aims to evaluate the optimal ratio of synthetic bone graft (SBG) material and platelet rich fibrin (PRF) mixed in a metal 3D-printed implant to enhance bone regeneration. METHODS: Specialized titanium hollow implants (5 mm in diameter and 6 mm in height for rabbit; 6 mm in diameter and 5 mm in height for pig) were designed and manufactured using 3D printing technology. The implants were divided into three groups and filled with different bone graft combinations, namely (1) SBG alone; (2) PRF to SBG in 1:1 ratio; (3) PRF to SBG in 2:1 ratio. These three groups were replicated tightly into each bone defect in distal femurs of rabbits (nine implants, n = 3) and femoral shafts of pigs (fifteen implants, n = 5). Animal tissue sections were obtained after euthanasia at the 8th postoperative week. The rabbit specimens were stained with analine blue, while the pig specimens were stained with Masson-Goldner's trichrome stain to perform histologically examination. All titanium hollow implants were well anchored, except in fracture specimens (three in the rabbit and one fracture in the pig). RESULT: Rabbit specimens under analine blue staining showed that collagen tissue increased by about 20% and 40% in the 1:1 ratio group and the 2:1 ratio group, respectively. Masson-Goldner's trichrome stain results showed that new bone growth increased by 32% in the 1:1 ratio PRF to SBG, while - 8% in the 2:1 ratio group. CONCLUSION: This study demonstrated that placing a 1:1 ratio combination of PRF and SBG in a stabilized titanium 3D printed implant resulted in an optimal increase in bone growth.


Assuntos
Regeneração Óssea , Fibrina Rica em Plaquetas , Impressão Tridimensional , Titânio , Animais , Coelhos , Regeneração Óssea/efeitos dos fármacos , Regeneração Óssea/fisiologia , Suínos , Fêmur/cirurgia , Substitutos Ósseos , Transplante Ósseo/métodos , Próteses e Implantes
20.
Biosens Bioelectron ; 258: 116328, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38692223

RESUMO

Implantable bioelectronics, integrated directly within the body, represent a potent biomedical solution for monitoring and treating a range of medical conditions, including chronic diseases, neural disorders, and cardiac conditions, through personalized medical interventions. Nevertheless, contemporary implantable bioelectronics rely heavily on rigid materials (e.g., inorganic materials and metals), leading to inflammatory responses and tissue damage due to a mechanical mismatch with biological tissues. Recently, soft electronics with mechanical properties comparable to those of biological tissues have been introduced to alleviate fatal immune responses and improve tissue conformity. Despite their myriad advantages, substantial challenges persist in surgical handling and precise positioning due to their high compliance. To surmount these obstacles, softening implantable bioelectronics has garnered significant attention as it embraces the benefits of both rigid and soft bioelectronics. These devices are rigid for easy standalone implantation, transitioning to a soft state in vivo in response to environmental stimuli, which effectively overcomes functional/biological problems inherent in the static mechanical properties of conventional implants. This article reviews recent research and development in softening materials and designs for implantable bioelectronics. Examples featuring tissue-penetrating and conformal softening devices highlight the promising potential of these approaches in biomedical applications. A concluding section delves into current challenges and outlines future directions for softening implantable device technologies, underscoring their pivotal role in propelling the evolution of next-generation bioelectronics.


Assuntos
Materiais Biocompatíveis , Técnicas Biossensoriais , Próteses e Implantes , Humanos , Técnicas Biossensoriais/instrumentação , Materiais Biocompatíveis/química , Desenho de Equipamento , Animais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...