Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Anal Bioanal Chem ; 408(22): 6201-11, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27379391

RESUMEN

A simple, rapid, and efficient ultrasound-assisted dispersive liquid-liquid microextraction (US-DLLME) method was developed for extraction of tetracycline residues from egg supplement samples, with subsequent determination by flow injection analysis (FIA) coupled to a liquid waveguide capillary cell (LWCC) and a controlled temperature heating bath. Tetracyclines react with diazotized p-sulfanilic acid, in a slightly alkaline medium, to form azo compounds that can be measured at 435 nm. The reaction sensitivity improved substantially (5.12-fold) using an in-line heating temperature of 45 °C. Multivariate methodology was used to optimize the factors affecting the extraction efficiency, considering the volumes of extraction and disperser solvents, sonication time, extraction time, and centrifugation time. Good linearity in the range 30-600 µg L(-1) was obtained for all the tetracyclines, with regression coefficients (r) higher than 0.9974. The limits of detection ranged from 6.4 to 11.1 µg L(-1), and the recoveries were in the range 85.7-96.4 %, with relative standard deviation lower than 9.8 %. Analyte recovery was improved by approximately 6 % when the microextraction was assisted by ultrasound. The results obtained with the proposed US-DLLME-FIA method were confirmed by a reference HPLC method and showed that the egg supplement samples analyzed were suitable for human consumption.


Asunto(s)
Antibacterianos/aislamiento & purificación , Suplementos Dietéticos/análisis , Huevos/análisis , Análisis de los Alimentos/métodos , Microextracción en Fase Líquida/métodos , Sonicación/métodos , Tetraciclinas/aislamiento & purificación , Antibacterianos/análisis , Cromatografía Líquida de Alta Presión/economía , Cromatografía Líquida de Alta Presión/instrumentación , Cromatografía Líquida de Alta Presión/métodos , Diseño de Equipo , Análisis de Inyección de Flujo/economía , Análisis de Inyección de Flujo/instrumentación , Análisis de Inyección de Flujo/métodos , Contaminación de Alimentos/análisis , Límite de Detección , Microextracción en Fase Líquida/economía , Microextracción en Fase Líquida/instrumentación , Sonicación/economía , Sonicación/instrumentación , Tetraciclinas/análisis
2.
Compr Rev Food Sci Food Saf ; 15(4): 705-719, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33401840

RESUMEN

This paper provides, for the first time, an overview of different aspects related to the quality of coffee beans and their volatile fractions: species/cultivars, geographic origins, bean defects, and types of beverages, processing, roasting, and storage. In other words, it concerns the complex relation between the quality of coffee seeds and their volatile components. It is an overview of 48 articles and considering 6 different aspects related to the quality of coffee and its aromatic fraction. The greatest numbers of published papers concerned "species and cultivars" and "defective seeds," both with 11 articles cited, followed by "storage" with 10 articles. Many aspects still require greater clarification, including the effects of geographical origin, processing, and roasting. Other issues that are better understood include the effects of species type, defective seeds, and storage conditions. Another topic that has received very little attention is the question of the existence of many different coffee cultivars within each species, which we believe should be further investigated, given that this can significantly affect the quality of the final beverage. Meanwhile, with the growing technological development in the areas of science and agriculture, there are many other aspects to be studied (or revisited), and the field of the aromatic quality of coffee provides ample opportunity for scientific investigation.

3.
Spectrochim Acta A Mol Biomol Spectrosc ; 227: 117774, 2020 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-31707016

RESUMEN

This paper describes the development and application of a paper-based analytical device (µPAD) for the determination of hydrogen peroxide, an important adulterant in milk. The method employs the reaction between hydrogen peroxide and guaiacol, catalyzed by peroxidase, producing a red product, which is then quantified by digital imaging. Experimental design methodology was used to optimize the experimental conditions. The linear concentration range was from 12.5 × 10-4 to 150 × 10-4 mol L-1, resulting in the regression equation AB = 0.02466 (±0.00192) + 17.053 (±0.750) C, with an excellent correlation coefficient (r = 0.986). The relative standard deviations obtained were 1.1 and 1.3% (intra-day), and 4.8 and 2.9% (inter-day), for 25.0 × 10-4 and 100 × 10-4 mol L-1 of hydrogen peroxide, respectively. The limits of detection and quantification were 3.54 × 10-4 and 11.8 × 10-4 mol L-1, respectively, with standard deviation of the blank of 0.002012. The proposed method was successfully applied for the determination of peroxide in milk samples, with recoveries between 92.2 and 109%. The proposed device constitutes a valuable analytical tool for the identification of hydrogen peroxide adulteration and offers advantages including low cost, simplicity, portability, and no (or minimal) requirement for sample pretreatment.


Asunto(s)
Peróxido de Hidrógeno/análisis , Leche/química , Papel , Animales , Peroxidasa/metabolismo , Estándares de Referencia
4.
Spectrochim Acta A Mol Biomol Spectrosc ; 71(5): 1999-2004, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18783980

RESUMEN

This paper describes an environmentally friendly method for quantitative determination of ranitidine using diffuse reflectance spectroscopy. This method is based on the reflectance measurements of the colored product produced from the spot test reaction between ranitidine and p-dimethylaminocinnamaldehyde (p-DAC), in acid medium, using filter paper as solid support. Experimental design methodologies were used to optimize the optimal conditions. All reflectance measurements were carried out at 590 nm and the linear range was from 1.42x10(-3) to 3.42x10(-2) mol L(-1), with a correlation coefficient of 0.997. The limit of detection was estimated to be 1.09x10(-3) mol L(-1) (R.S.D.=1.9%). The proposed method was successfully applied to the determination of ranitidine in commercial brands of pharmaceuticals and no interferences were observed from the common excipients in formulations. The results obtained by the proposed method were favorably compared with those obtained by an official procedure at 95% confidence level. Additionally, the method was also applied to the determination of ranitidine in human urine showing excellent recoveries (99.6-100.3%).


Asunto(s)
Ambiente , Preparaciones Farmacéuticas/química , Ranitidina/análisis , Orina/química , Antiulcerosos/análisis , Antiulcerosos/química , Calibración , Tecnología Química Verde/métodos , Humanos , Ranitidina/química , Análisis Espectral/métodos , Urinálisis/métodos , Urinálisis/normas
5.
Talanta ; 196: 523-529, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30683400

RESUMEN

New and reliable methodologies are described for the determination of amino acids in gym supplements, offering rapid and clean analysis, with low generation of waste. The proposed methods are based on the reaction between ninhydrin and amino acids in acetate buffer medium (pH 4.75). Experimental design tools were used to optimize the analytical conditions. The linear range obtained for both methodologies was 20.0-350.0 mg L-1. The detection (LOD) and quantification (LOQ) limits were 6.2 and 21.0 mg L-1, respectively, for diffuse reflectance using a paper filter with hydrophobic barriers to increase the sensitivity and homogeneity of the colored product, and 5.7 and 18.8 mg L-1, respectively, for digital image analysis. A USB device was used in the diffuse reflectance spectroscopy method for heating the filter paper, providing speed and portability for the developed methodology. The methods showed good results when applied to gym supplement samples, with recoveries in the range 93.1-110%.

6.
Food Chem ; 272: 488-493, 2019 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-30309572

RESUMEN

1H NMR spectroscopy combined with chemometrics was employed to discriminate lager beer samples from two different classes, according to their style and information provided on the label. Partial replacement of barley malt by adjuncts is a common practice adopted by large breweries, which can lead to a decrease in diastatic power, requiring the use of exogenous enzymes. For this reason, small variations in the spectral profile can occur in the carbohydrates region. Many studies have focused on differentiating beers according to type and brewing process. However, there have no studies concerning the discrimination of beers of the same type that differ only in style, using 1H NMR spectroscopy. In this study PCA (first three components explained 81.5% of the dataset variability), PLS-DA and SIMCA models proved to be powerful tool with predict power higher than 90% for distinguishing lager beers based on the raw materials employed in the brewing process.


Asunto(s)
Cerveza/análisis , Espectroscopía de Protones por Resonancia Magnética/métodos , Brasil , Análisis Discriminante , Concentración de Iones de Hidrógeno , Análisis de los Mínimos Cuadrados , Análisis de Componente Principal
7.
Anal Sci ; 24(7): 871-6, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18614828

RESUMEN

A flow-injection (FI) spectrophotometric procedure exploiting merging zones is proposed for the determination of azithromycin in pharmaceutical formulations. The method is based on the reaction of azithromycin with tetrachloro-p-benzoquinone (p-chloranil) accelerated by hydrogen peroxide and conducted in a methanol medium, producing a purple-red color compound (lambda(max) = 540 nm). The FI system and the experimental conditions were optimized using a multivariate method. Beer's law is obeyed in a concentration range of 50 - 1600 microg mL(-1) with an excellent correlation coefficient (r = 0.9998). The detection limit and the quantification limit were 6.6 and 22.1 microg mL(-1), respectively. No interference was observed from the common excipients, and the recoveries were within 98.6 to 100.4%. The procedure was applied to the determination of azithromycin in pharmaceuticals with a high sampling rate (65 samples h(-1)). The results obtained by the proposed method were in good agreement with those obtained by the comparative method at 95% confidence level.


Asunto(s)
Antibacterianos/análisis , Azitromicina/análisis , Química Farmacéutica/métodos , Cloranilo/química , Análisis de Inyección de Flujo/métodos , Peróxido de Hidrógeno/química , Espectrofotometría/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
8.
Artículo en Inglés | MEDLINE | ID: mdl-17646125

RESUMEN

This paper describes an analytical reflectometric method that has an objective not only the industrial quality control but also to detect possible falsifications and/or adulterations of propranolol in pharmaceutical formulations. The method is based on the diffuse reflectance measurements of the colored product (III) of the spot test reaction between propranolol hydrochloride (I) and 2,6-dichloroquinone-4-chloroimide (II) using filter paper as solid support. Spot test conditions have been investigated using experimental design in order to identify and optimize the critical factors. The factors evaluated were DCQ concentration, propranolol solvent and DCQ solvent. The best reaction conditions were achieved with the addition of 30 microL of propranolol solution in ethanol 35% (v/v) and 30 microL of DCQ solution at 70 mg mL(-1) in acetone, in this order. All reflectance measurements were carried out at 500 nm and the linear range was from 8.45x10(-4) to 8.45x10(-2)mol L(-1) (r=0.998). The limit of detection was 1.01x10(-4)mol L(-1). No interference was observed from the assessed excipients and drugs. The method was applied to determine propranolol in commercial brands of pharmaceuticals. The results obtained by the proposed method were favorably compared with those given by the British Pharmacopoeia procedure.


Asunto(s)
Preparaciones Farmacéuticas/química , Propranolol/análisis , Análisis Espectral/métodos , Benzoquinonas/química , Difusión , Iminas/química , Propranolol/química , Estándares de Referencia
9.
Talanta ; 182: 1-21, 2018 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-29501128

RESUMEN

Tetracyclines are widely used for both the treatment and prevention of diseases in animals as well as for the promotion of rapid animal growth and weight gain. This practice may result in trace amounts of these drugs in products of animal origin, such as milk and eggs, posing serious risks to human health. The presence of tetracycline residues in foods can lead to the transmission of antibiotic-resistant pathogenic bacteria through the food chain. In order to ensure food safety and avoid exposure to these substances, national and international regulatory agencies have established tolerance levels for authorized veterinary drugs, including tetracycline antimicrobials. In view of that, numerous sensitive and specific methods have been developed for the quantification of these compounds in different food matrices. One will note, however, that the determination of trace residues in foods such as milk and eggs often requires extensive sample extraction and preparation prior to conducting instrumental analysis. Sample pretreatment is usually the most complicated step in the analytical process and covers both cleaning and pre-concentration. Optimal sample preparation can reduce analysis time and sources of error, enhance sensitivity, apart from enabling unequivocal identification, confirmation and quantification of target analytes. The development and implementation of more environmentally friendly analytical procedures, which involve the use of less hazardous solvents and smaller sample sizes compared to traditional methods, is a rapidly increasing trend in analytical chemistry. This review seeks to provide an updated overview of the main trends in sample preparation for the determination of tetracycline residues in foodstuffs. The applicability of several extraction and clean-up techniques employed in the analysis of foodstuffs, especially milk and egg samples, is also thoroughly discussed.


Asunto(s)
Antibacterianos/análisis , Residuos de Medicamentos/análisis , Huevos/análisis , Leche/química , Tetraciclinas/análisis , Drogas Veterinarias/análisis , Animales , Cromatografía Liquida/instrumentación , Cromatografía Liquida/métodos , Electroforesis/instrumentación , Electroforesis/métodos , Ensayo de Inmunoadsorción Enzimática/métodos , Contaminación de Alimentos/análisis , Inocuidad de los Alimentos , Humanos , Mediciones Luminiscentes/instrumentación , Mediciones Luminiscentes/métodos
10.
Anal Chim Acta ; 997: 16-23, 2018 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-29149990

RESUMEN

In this paper, we describe a validated paper-based microfluidic analytical device for the simultaneous quantification of two important biomarkers of renal function in urine. This paper platform provides an inexpensive, simple, and easy to use colorimetric method for the quantification of creatinine (CRN) and uric acid (UA) in urine samples. The microfluidic paper-based analytical device (µPAD) consists of a main channel with three identical arms, each containing a circular testing zone and a circular uptake zone. Creatinine detection is based on the Jaffé reaction, in which CRN reacts with picrate to form an orange-red product. Uric acid quantification is based on the reduction of Fe3+ to Fe2+ by UA, which is detected in a colorimetric reaction using 1,10-phenanthroline. Under optimum conditions, obtained through chemometrics, the concentrations of the analytes showed good linear correlations with the effective intensities, and the method presented satisfactory repeatability. The limits of detection and the linear ranges, respectively, were 15.7 mg L-1 and 50-600 mg L-1 for CRN and 16.5 mg L-1 and 50-500 mg L-1 for UA. There were no statistically significant differences between the results obtained using the µPAD and a chromatographic comparative method (Student's t-test at 95% confidence level).


Asunto(s)
Colorimetría/métodos , Creatinina/orina , Riñón/fisiología , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , Ácido Úrico/orina , Biomarcadores/orina , Cromatografía , Humanos , Límite de Detección , Papel , Fenantrolinas/química
11.
Spectrochim Acta A Mol Biomol Spectrosc ; 189: 221-226, 2018 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-28820974

RESUMEN

A sensitive, rapid and robust method based on the use of stabilizer-free silver nanoparticles was developed for lead detection in honey. Silver nanoparticles were synthesized without the presence of any stabilizers using silver nitrate and sodium borohydride as precursors where the latter was applied as reducing agent. The optimization of the experimental variables (AgNO3 and NaBH4) for the formation of the nanoparticles was carried out using varying volumes of these solutions. Spectrophotometric measurements at 393nm showed a linear working range between 0.0500 and 0.167mgL-1 lead (R=0.994), with limits of detection (LOD) and quantification (LOQ) of 0.0135 and 0.0451mgL-1, respectively. The proposed method proved to be a significantly sensitive mechanism for lead detection in honey samples.


Asunto(s)
Miel/análisis , Plomo/análisis , Nanopartículas del Metal/química , Plata/química , Color , Flores/química , Concentración de Iones de Hidrógeno , Límite de Detección , Nanopartículas del Metal/ultraestructura , Concentración Osmolar
12.
Spectrochim Acta A Mol Biomol Spectrosc ; 204: 432-435, 2018 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-29966896

RESUMEN

A simple, fast, low-cost, portable, and eco-friendly method using a spot test on a paper platform, together with diffuse reflectance spectroscopy, was developed and validated for the quantification of aluminum hydrochloride, a potential neurotoxic agent, in antiperspirant samples. The determination of aluminum hydrochloride was performed at a wavelength of 615 nm, by measuring consumption of the purple colorimetric reagent Alizarin S, due to reaction with aluminum. The linear range was from 10.0 to 125.0 mg L-1 and could be described by the equation: AR = 0.4479 - 0.002543 CAl (R = 0.999). The limits of detection (LOD) and quantification (LOQ) were 3.06 and 10.2 mg L-1, respectively. The method was specific, accurate, and repeatable, with relative standard deviation (RSD) <5.0%. The recovery was between 92.2 and 103.4%. The method was successfully used for the determination of aluminum hydrochloride in commercial antiperspirant samples, revealing concentrations below the maximum permitted by current legislation.


Asunto(s)
Compuestos de Aluminio/análisis , Antitranspirantes/química , Cloruros/análisis , Colorimetría/métodos , Cloruro de Aluminio , Compuestos de Aluminio/química , Antitranspirantes/análisis , Cloruros/química , Límite de Detección , Modelos Lineales , Papel , Reproducibilidad de los Resultados
13.
Steroids ; 138: 47-56, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30003910

RESUMEN

Counterfeiting and adulteration of pharmaceuticals is a prevalent problem worldwide and represents a major health risk to the population, with anabolic steroids being one of the main classes of drugs consumed and obtained from dubious sources. In this work, we propose the use of the 1H NMR technique to evaluate formulations containing anabolic steroids, with analysis of 40 samples of anabolic drugs that are used in injectable and capsule forms. The samples analyzed presented the following active ingredients: testosterone propionate, testosterone phenylpropionate, testosterone isocaproate, testosterone decanoate, testosterone cypionate, testosterone undecanoate, stanozolol, drostanolone propionate, trenbolone acetate, oxymetholone, and methandrostenolone. The 1H NMR spectroscopic measurements were performed using a 600 MHz Bruker Avance III spectrometer, with deuterated chloroform (CDCl3) containing 0.1% TMS as solvent. Of the 40 samples analyzed, eight did not show the presence of the active principle stated on the label. Three types of adulteration were found in the analyzed samples: absence of the active ingredient, adulteration with other substances, and concentration values below those indicated on the label. Sildenafil citrate was found in four samples. The GC-MS technique was used to confirm the adulteration results found using 1H NMR. Quantitative determination by NMR was performed using internal standard and ERETIC 2 methods, and the results obtained were statistically the same.


Asunto(s)
Espectroscopía de Protones por Resonancia Magnética/métodos , Citrato de Sildenafil/química , Esteroides/química , Congéneres de la Testosterona/química , Cromatografía de Gases y Espectrometría de Masas
14.
Talanta ; 179: 292-299, 2018 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-29310234

RESUMEN

This work proposes the use of near infrared (NIR) spectroscopy in diffuse reflectance mode and multivariate statistical process control (MSPC) based on principal component analysis (PCA) for real-time monitoring of the coffee roasting process. The main objective was the development of a MSPC methodology able to early detect disturbances to the roasting process resourcing to real-time acquisition of NIR spectra. A total of fifteen roasting batches were defined according to an experimental design to develop the MSPC models. This methodology was tested on a set of five batches where disturbances of different nature were imposed to simulate real faulty situations. Some of these batches were used to optimize the model while the remaining was used to test the methodology. A modelling strategy based on a time sliding window provided the best results in terms of distinguishing batches with and without disturbances, resourcing to typical MSPC charts: Hotelling's T2 and squared predicted error statistics. A PCA model encompassing a time window of four minutes with three principal components was able to efficiently detect all disturbances assayed. NIR spectroscopy combined with the MSPC approach proved to be an adequate auxiliary tool for coffee roasters to detect faults in a conventional roasting process in real-time.


Asunto(s)
Café/química , Culinaria , Análisis de los Alimentos/instrumentación , Modelos Estadísticos , Espectroscopía Infrarroja Corta/estadística & datos numéricos , Estudios de Factibilidad , Análisis de los Alimentos/métodos , Humanos , Análisis Multivariante , Análisis de Componente Principal , Factores de Tiempo
15.
Food Sci Biotechnol ; 27(1): 19-26, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30263720

RESUMEN

With globalization, it has become necessary to adopt policies to regulate the coffee market, addressing problems including the authenticity and traceability of products. It is therefore important to establish methodologies that can help to safeguard the interests of producer countries and add value to products. For this purpose, the use of NMR combined with multivariate statistical procedures can be an attractive option. The aim of this study was to develop a fast and effective technique, using 1H NMR coupled with multivariate statistics, to create a fingerprint of roasted coffees, distinguishing them according to the main Brazilian producer regions. Several compounds suitable for differentiating roasted coffees were identified in the fingerprint. Discriminant analysis revealed good distinction among the samples. The compounds catechol, trigonelline, caffeine, and n-methylpyridine were most important for the differentiation. The findings should assist coffee-producing countries in adopting measures to protect their markets and to add value to coffee products.

16.
Anal Sci ; 23(12): 1383-9, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18071223

RESUMEN

A sensitive flow-injection (FI) procedure with spectrophotometric detection in a micellar medium is proposed for the determination of novalgin. The method is based on the instantaneous formation of a red-orange product (lambda(max) = 510 nm) after the reaction between novalgin and p-dimethylaminocinnamaldehyde (p-DAC) in a dilute acid medium. The sensitivity of this reaction was increased by a factor of 5.6 in the presence of sodium dodecyl sulfate (SDS). Experimental design methodologies were used to optimize the chemical and FI variables. The calibration curve was linear in the range of 1.45 x 10(-6) to 2.90 x 10(-5) mol L(-1) with an excellent correlation coefficient (r = 0.9999). The detection limit was 1.31 x 10(-7) mol L(-1) (n = 20, RSD = 2.0%). No interferences were observed from the common excipients. The results obtained by the proposed method were favorably compared with those given by the iodometric reference method at 95% confidence level.


Asunto(s)
Antiinflamatorios no Esteroideos/análisis , Dipirona/análisis , Análisis de Inyección de Flujo , Indicadores y Reactivos , Micelas , Soluciones Farmacéuticas , Estándares de Referencia , Reproducibilidad de los Resultados , Espectrofotometría Ultravioleta , Comprimidos
17.
Talanta ; 174: 572-580, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28738624

RESUMEN

Semiconductor quantum dots (QDs) have demonstrated a great potential as fluorescent probes for heavy metals monitoring. However, their great reactivity, whose tunability could be difficult to attain, could impair selectivity yielding analytical results with poor accuracy. In this work, the combination in the same analysis of multiple QDs, each with a particular ability to interact with the analyte, assured a multi-point detection that was not only exploited for a more precise analyte discrimination but also for the simultaneous discrimination of multiple mutually interfering species, in the same sample. Three different MPA-CdTe QDs (2.5, 3.0 and 3.8nm) with a good size distribution, confirmed by the FWHM values of 48.6, 55.4 and 80.8nm, respectively, were used. Principal component analysis (PCA) and partial least squares regression (PLS) were used for fluorescence data analysis. Mixtures of two MPA-CdTe QDs, emitting at different wavelength namely 549/566, 549/634 and 566/634nm were assayed. The 549/634nm emitting QDs mixture provided the best results for the discrimination of distinct ions on binary and ternary mixtures. The obtained RMSECV and R2CV values for the binary mixture were good, namely, from 0.01 to 0.08mgL-1 and from 0.74 to 0.89, respectively. Regarding the ternary mixture the RMSECV and R2CV values were good for Hg(II) (0.06 and 0.73mgL-1, respectively) and Pb(II) (0.08 and 0.87mg L-1, respectively) and acceptable for Cu(II) (0.02 and 0.51mgL-1, respectively). In conclusion, the obtained results showed that the developed approach is capable of resolve binary and ternary mixtures of Pb (II), Hg (II) and Cu (II), providing accurate information about lead (II) and mercury (II) concentration and signaling the occurrence of Cu (II).

18.
Spectrochim Acta A Mol Biomol Spectrosc ; 153: 386-92, 2016 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-26344484

RESUMEN

An environmentally reliable analytical methodology was developed for direct quantification of tetracycline (TC) and oxytetracycline (OTC) using continuous flow injection analysis with spectrophotometric detection. The method is based on the diazo coupling reaction between the tetracyclines and diazotized sulfanilic acid in a basic medium, resulting in the formation of an intense orange azo compound that presents maximum absorption at 434 nm. Experimental design was used to optimize the analytical conditions. The proposed technique was validated over the concentration range of 1 to 40 µg mL(-1), and was successfully applied to samples of commercial veterinary pharmaceuticals. The detection (LOD) and quantification (LOQ) limits were 0.40 and 1.35 µg mL(-1), respectively. The samples were also analyzed by an HPLC method, and the results showed agreement with the proposed technique. The new flow injection method can be immediately used for quality control purposes in the pharmaceutical industry, facilitating monitoring in real time during the production processes of tetracycline formulations for veterinary use.


Asunto(s)
Análisis de Inyección de Flujo/métodos , Tetraciclinas/análisis , Colorimetría , Indicadores y Reactivos , Límite de Detección , Oxitetraciclina/análisis , Estándares de Referencia , Ácidos Sulfanílicos/química , Tetraciclinas/química , Drogas Veterinarias/análisis
19.
Crit Rev Anal Chem ; 46(2): 83-92, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-25633422

RESUMEN

Coffee is a ubiquitous food product of considerable economic importance to the countries that produce and export it. The adulteration of roasted coffee is a strategy used to reduce costs. Conventional methods employed to identify adulteration in roasted and ground coffee involve optical and electron microscopy, which require pretreatment of samples and are time-consuming and subjective. Other analytical techniques have been studied that might be more reliable, reproducible, and widely applicable. The present review provides an overview of three analytical approaches (physical, chemical, and biological) to the identification of coffee adulteration. A total of 30 published articles are considered. It is concluded that despite the existence of a number of excellent studies in this area, there still remains a lack of a suitably sensitive and widely applicable methodology able to take into account the various different aspects of adulteration, considering coffee varieties, defective beans, and external agents.


Asunto(s)
Café/química , Contaminación de Alimentos/análisis , Microscopía Electrónica de Rastreo
20.
Anal Sci ; 32(4): 413-7, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27063713

RESUMEN

One of the quality indicators for honey is 5-(hydroxymethyl)-2-furaldehyde (HMF), which is formed during the heating or aging of honey. The International Honey Commission recommends three methods for the determination of HMF in honey: the Winkler method, the White method, and determination by HPLC. The Winkler method uses the carcinogenic substance p-toluidine, which is not in accordance with the principles of Green Chemistry. The present work describes the determination of HMF in honey by flow injection analysis (FIA) using a modified Winkler method, replacing p-toluidine with p-aminobenzoic acid. The linear range was 1.00 to 40.0 mg L(-1), the limit of detection (LOD) was 0.43 mg L(-1), and the limit of quantification (LOQ) was 1.32 mg L(-1). The method is an efficient and environmentally friendly technique for the analysis of HMF in honey.


Asunto(s)
Análisis de Inyección de Flujo , Furaldehído/análogos & derivados , Miel/análisis , Ácido 4-Aminobenzoico/química , Cromatografía Líquida de Alta Presión , Furaldehído/análisis , Toluidinas/química
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda