Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 211
Filtrar
1.
AJR Am J Roentgenol ; 2023 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-37877595

RESUMEN

Current CT oral contrast agents improve the conspicuity and confidence for bowel and peritoneal findings in many clinical scenarios, particularly for outpatient and oncologic abdominopelvic imaging. Yet, existing positive and neutral oral contrast agents may diminish the detectability of certain radiologic findings, frequently in the same scans in which the oral contrast agent improves the detectability of other findings. With ongoing improvements in CT technology, particularly multi-energy CT, opportunities are opening for new types of oral contrast agents to further improve anatomic delineation and disease detection using CT. The CT signal of new dark oral contrast agents and of new high-Z oral contrast agents promise to combine the strengths of both positive and neutral oral CT contrast agents by providing distinct CT appearances in comparison with bodily tissues, iodinated IV contrast agents, and other classes of new CT contrast agents. High-Z oral contrast agents will unlock previously inaccessible capabilities of multi-energy CT, particularly photon-counting detector CT, for differentiating simultaneously administered IV and oral contrast agents; this technique will allow generation of rich 3D, intuitive, perfectly co-registered, high-resolution image sets with individual contrast-agent "colors" that provide compelling clarity for intertwined intraabdominal anatomy and disease processes.

2.
Radiographics ; 43(6): e220181, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37227944

RESUMEN

Quantitative imaging biomarkers of liver disease measured by using MRI and US are emerging as important clinical tools in the management of patients with chronic liver disease (CLD). Because of their high accuracy and noninvasive nature, in many cases, these techniques have replaced liver biopsy for the diagnosis, quantitative staging, and treatment monitoring of patients with CLD. The most commonly evaluated imaging biomarkers are surrogates for liver fibrosis, fat, and iron. MR elastography is now routinely performed to evaluate for liver fibrosis and typically combined with MRI-based liver fat and iron quantification to exclude or grade hepatic steatosis and iron overload, respectively. US elastography is also widely performed to evaluate for liver fibrosis and has the advantage of lower equipment cost and greater availability compared with those of MRI. Emerging US fat quantification methods can be performed along with US elastography. The author group, consisting of members of the Society of Abdominal Radiology (SAR) Liver Fibrosis Disease-Focused Panel (DFP), the SAR Hepatic Iron Overload DFP, and the European Society of Radiology, review the basics of liver fibrosis, fat, and iron quantification with MRI and liver fibrosis and fat quantification with US. The authors cover technical requirements, typical case display, quality control and proper measurement technique and case interpretation guidelines, pitfalls, and confounding factors. The authors aim to provide a practical guide for radiologists interpreting these examinations. © RSNA, 2023 See the invited commentary by Ronot in this issue. Quiz questions for this article are available in the supplemental material.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Sobrecarga de Hierro , Hepatopatías , Humanos , Hierro , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Hígado/diagnóstico por imagen , Hígado/patología , Imagen por Resonancia Magnética/métodos , Hepatopatías/patología , Sobrecarga de Hierro/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Radiólogos , Biomarcadores
3.
Eur Radiol ; 32(11): 7936-7945, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35486170

RESUMEN

OBJECTIVES: To compare the performance of conventional versus spectral-based electronic stool cleansing for iodine-tagged CT colonography (CTC) using a dual-layer spectral detector scanner. METHODS: We retrospectively evaluated iodine contrast stool-tagged CTC scans of 30 consecutive patients (mean age: 69 ± 8 years) undergoing colorectal cancer screening obtained on a dual-layer spectral detector CT scanner. One reader identified locations of electronic cleansing artifacts (n = 229) on conventional and spectral cleansed images. Three additional independent readers evaluated these locations using a conventional cleansing algorithm (Intellispace Portal) and two experimental spectral cleansing algorithms (i.e., fully transparent and translucent tagged stool). For each cleansed image set, readers recorded the severity of over- and under-cleansing artifacts on a 5-point Likert scale (0 = none to 4 = severe) and readability compared to uncleansed images. Wilcoxon's signed-rank tests were used to assess artifact severity, type, and readability (worse, unchanged, or better). RESULTS: Compared with conventional cleansing (66% score ≥ 2), the severity of overall cleansing artifacts was lower in transparent (60% score ≥ 2, p = 0.011) and translucent (50% score ≥ 2, p < 0.001) spectral cleansing. Under-cleansing artifact severity was lower in transparent (49% score ≥ 2, p < 0.001) and translucent (39% score ≥ 2, p < 0.001) spectral cleansing compared with conventional cleansing (60% score ≥ 2). Over-cleansing artifact severity was worse in transparent (17% score ≥ 2, p < 0.001) and translucent (14% score ≥ 2, p = 0.023) spectral cleansing compared with conventional cleansing (9% score ≥ 2). Overall readability was significantly improved in transparent (p < 0.001) and translucent (p < 0.001) spectral cleansing compared with conventional cleansing. CONCLUSIONS: Spectral cleansing provided more robust electronic stool cleansing of iodine-tagged stool at CTC than conventional cleansing. KEY POINTS: • Spectral-based electronic cleansing of tagged stool at CT colonography provides higher quality images with less perception of artifacts than does conventional cleansing. • Spectral-based electronic cleansing could potentially advance minimally cathartic approach for CT colonography. Further clinical trials are warranted.


Asunto(s)
Colonografía Tomográfica Computarizada , Yodo , Humanos , Persona de Mediana Edad , Anciano , Colonografía Tomográfica Computarizada/métodos , Estudios Retrospectivos , Algoritmos , Catárticos , Artefactos
4.
Eur Radiol ; 32(7): 4749-4759, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35083528

RESUMEN

OBJECTIVES: To investigate the differentiation of premalignant from benign colorectal polyps detected by CT colonography using deep learning. METHODS: In this retrospective analysis of an average risk colorectal cancer screening sample, polyps of all size categories and morphologies were manually segmented on supine and prone CT colonography images and classified as premalignant (adenoma) or benign (hyperplastic polyp or regular mucosa) according to histopathology. Two deep learning models SEG and noSEG were trained on 3D CT colonography image subvolumes to predict polyp class, and model SEG was additionally trained with polyp segmentation masks. Diagnostic performance was validated in an independent external multicentre test sample. Predictions were analysed with the visualisation technique Grad-CAM++. RESULTS: The training set consisted of 107 colorectal polyps in 63 patients (mean age: 63 ± 8 years, 40 men) comprising 169 polyp segmentations. The external test set included 77 polyps in 59 patients comprising 118 polyp segmentations. Model SEG achieved a ROC-AUC of 0.83 and 80% sensitivity at 69% specificity for differentiating premalignant from benign polyps. Model noSEG yielded a ROC-AUC of 0.75, 80% sensitivity at 44% specificity, and an average Grad-CAM++ heatmap score of ≥ 0.25 in 90% of polyp tissue. CONCLUSIONS: In this proof-of-concept study, deep learning enabled the differentiation of premalignant from benign colorectal polyps detected with CT colonography and the visualisation of image regions important for predictions. The approach did not require polyp segmentation and thus has the potential to facilitate the identification of high-risk polyps as an automated second reader. KEY POINTS: • Non-invasive deep learning image analysis may differentiate premalignant from benign colorectal polyps found in CT colonography scans. • Deep learning autonomously learned to focus on polyp tissue for predictions without the need for prior polyp segmentation by experts. • Deep learning potentially improves the diagnostic accuracy of CT colonography in colorectal cancer screening by allowing for a more precise selection of patients who would benefit from endoscopic polypectomy, especially for patients with polyps of 6-9 mm size.


Asunto(s)
Pólipos del Colon , Colonografía Tomográfica Computarizada , Neoplasias Colorrectales , Aprendizaje Profundo , Lesiones Precancerosas , Anciano , Pólipos del Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/métodos , Colonoscopía , Neoplasias Colorrectales/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Lesiones Precancerosas/diagnóstico por imagen , Estudios Retrospectivos , Sensibilidad y Especificidad
5.
AJR Am J Roentgenol ; 218(2): 290-299, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34406059

RESUMEN

BACKGROUND. The value of dual-energy CT (DECT) for bowel wall assessment is increasingly recognized. Although technical improvements reduce peristalsis artifact in conventional CT, the effects of peristalsis on DECT image reconstructions remain poorly studied. OBJECTIVE. The purpose of this study was to evaluate the influence of different DECT scanners and enteric contrast agents on the severity of bowel peristalsis artifact in vitro. METHODS. To simulate bowel peristalsis, a 3-cm-diameter corrugated hollow tube representing the bowel was oscillated constantly in the z-axis within a larger water-filled cylinder. The bowel was serially filled with air, water, and iodinated or experimental dark contrast material and scanned on four different DECT platforms (spectral detector, rapid peak kilovoltage switching, split filter, and dual source) to reconstruct 120-kVp-like and iodine images. Two readers rated each image reconstruction for artifact severity from 0 (none) to 3 (severe) and recorded the degree to which iodine images depicted bowel wall hyperattenuation on 120-kVp-like images as artifactual. Artifact severity scores were compared by ANOVA with Bonferroni correction. RESULTS. Interrater agreement on artifact scores was excellent (intraclass correlation coefficient, 0.82 [95% CI, 0.79-0.84]). For 120-kVp-like images, mean peristalsis artifact scores were lower (all p < .001) for split-filter (1.47) and dual-source (1.86) scanners than for spectral-detector (2.58) and rapid-kilovoltage-switching (2.74) scanners. Compared with those on 120-kVp images, peristalsis artifacts on iodine images were less severe for spectral-detector (score, 1.03; p < .001) and rapid-kilovoltage-switching (2.09; p < .001) systems but more severe for dual-source (2.77; p < .001) and split-filter (2.62; p < .001) systems. Peristalsis artifact was rated less severe with experimental dark bowel contrast medium (score, 1.79) than with other bowel contrast agents (all p < .001). Iodine images helped identify bowel wall hyperattenuation as artifactual in 94.7% of reviewed cases for spectral-detector and 40.7% of cases for rapid-kilovoltage-switching scanners. CONCLUSION. For spectral-detector and rapid-kilovoltage-switching DECT, iodine images minimize peristalsis artifact, but for dual-source and split-filter DECT, mixed 120-kVp-like images are preferred. Compared with iodinated contrast material and water, experimental dark bowel contrast material reduces peristalsis artifact. CLINICAL IMPACT. Knowledge of the preferred images for reducing peristalsis artifact can lessen the effect of peristalsis on clinical DECT interpretation. Dark enteric contrast agents, when they become clinically available, may further reduce the effects of peristalsis.


Asunto(s)
Artefactos , Medios de Contraste , Peristaltismo , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Técnicas In Vitro , Fantasmas de Imagen
6.
AJR Am J Roentgenol ; 219(2): 233-243, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35293233

RESUMEN

BACKGROUND. Data are limited regarding utility of positive oral contrast material for peritoneal tumor detection on CT. OBJECTIVE. The purpose of this article is to compare positive versus neutral oral contrast material for detection of malignant deposits in nonsolid intraabdominal organs on CT. METHODS. This retrospective study included 265 patients (133 men, 132 women; median age, 61 years) who underwent an abdominopelvic CT examination in which the report did not suggest presence of malignant deposits and a subsequent CT examination within 6 months in which the report indicated at least one unequivocal malignant deposit. Examinations used positive (iohexol; n = 100) or neutral (water; n = 165) oral agents. A radiologist reviewed images to assess whether the deposits were visible (despite clinical reports indicating no deposits) on unblinded comparison with the follow-up examinations; identified deposits were assigned to one of seven intraabdominal compartments. The radiologist also assessed adequacy of bowel filling with oral contrast material. Two additional radiologists independently reviewed examinations in blinded fashion for malignant deposits. NPV was assessed of clinical CT reports and blinded retrospective readings for detection of malignant deposits visible on unblinded comparison with follow-up examinations. RESULTS. Unblinded review identified malignant deposits in 58.1% (154/265) of examinations. In per-patient analysis of clinical reports, NPV for malignant deposits was higher for examinations with adequate bowel filling with positive oral contrast material (65.8% [25/38]) than for examinations with inadequate bowel filling with positive oral contrast material (45.2% [28/62], p = .07) or with neutral oral contrast material regardless of bowel filling adequacy (35.2% [58/165], p = .002). In per-compartment analysis of blinded interpretations, NPV was higher for examinations with adequate and inadequate bowel filling with positive oral contrast material than for examinations with neutral oral contrast regardless of bowel filling adequacy (reader 1: 94.7% [234/247] and 92.5% [382/413] vs 88.3% [947/1072], both p = .045; reader 2: 93.1% [228/245] and 91.6% [361/394] vs 85.9% [939/1093], both p = .01). CONCLUSION. CT has suboptimal NPV for malignant deposits in intraabdominal nonsolid organs. Compared with neutral material, positive oral contrast material improves detection, particularly with adequate bowel filling. CLINICAL IMPACT. Optimization of bowel preparation for oncologic CT may help avoid potentially severe clinical consequences of missed malignant deposits.


Asunto(s)
Medios de Contraste , Tomografía Computarizada por Rayos X , Femenino , Humanos , Intestinos , Yohexol , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
7.
J Magn Reson Imaging ; 54(3): 728-736, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33665942

RESUMEN

BACKGROUND: MR enterography (MRE) is generally performed without bowel preparation, but the frequency and extent by which bowel contents affect bowel wall visualization are poorly described in the literature. PURPOSE: To evaluate MRE bowel wall visualization quality relative to bowel lumen contents and patient demographics. STUDY TYPE: Retrospective, single-center. POPULATION: One hundred and four consecutive patients (mean age 29 years, range 5-76 years) without prior bowel resection who had undergone MRE. FIELD STRENGTH/SEQUENCE: 3 T (N = 87) or 1.5 T (N = 17)/T2-weighted single-shot spin echo (T2WI) and fat-saturated T1-weighted gradient echo (T1WI) without and with gadolinium. ASSESSMENT: For the proximal and distal jejunum and ileum and colon, three readers independently categorized bowel lumen signal (water = bright T2 dark T1, T1-bright, or air = dark T2 and T1 signal) and scored distension (0 = poor, 1 = moderate, 2 = well) and wall enhancement (0 = unclear, 1 = perceptible, 2 = clear) based upon gadolinium enhanced T1WI for the 104 MRE exams). The bowel visualization score was the sum of the wall enhancement and distension scores and was considered adequate if ≥3. STATISTICAL TESTS: Wilcoxon signed-rank test. RESULTS: The bowel lumen content was water signal in 93% (97/104 scans), 92% (95/104), 98% (102/104), and 93% (92/104) of the proximal and distal jejunum and proximal and distal ileum, respectively, but only in 12.5% (13/104) of the colon. There was adequate bowel visualization of 53.8%, 77.8%, 84.6%, 90.4% of the proximal and distal jejunum and proximal and distal ileum, respectively, but only 19.2% of the colon. In children (age < 18 years), the visualization score of the ileum was lower when the adjacent colon contained air (2.4 ± 0.97) compared to water (3.75 ± 0.29, P < 0.05) or T1-bright material (3.21 ± 0.82, P < 0.05). DATA CONCLUSION: Without bowel preparation, colon wall visualization was often unsatisfactory at MRE, and air-filled colon also degraded small bowel visualization, particularly in children. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Medios de Contraste , Imagen por Resonancia Magnética , Adolescente , Adulto , Anciano , Niño , Preescolar , Demografía , Gadolinio , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
8.
AJR Am J Roentgenol ; 217(3): 651-663, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33377415

RESUMEN

Dual-energy CT (DECT) overcomes several limitations of conventional single-energy CT (SECT) for the evaluation of gastrointestinal diseases. This article provides an overview of practical aspects of the DECT technology and acquisition protocols, reviews existing clinical applications, discusses current challenges, and describes future directions, with a focus on gastrointestinal imaging. A head-to-head comparison of technical specifications among DECT scanner implementations is provided. Energy- and material-specific DECT image reconstructions enable retrospective (i.e., after examination acquisition) image quality adjustments that are not possible using SECT. Such adjustments may, for example, correct insufficient contrast bolus or metal artifacts, thereby potentially avoiding patient recalls. A combination of low-energy monochromatic images, iodine maps, and virtual unenhanced images can be included in protocols to improve lesion detection and disease characterization. Relevant literature is reviewed regarding use of DECT for evaluation of the liver, gallbladder, pancreas, and bowel. Challenges involving cost, workflow, body habitus, and variability in DECT measurements are considered. Artificial intelligence and machine-learning image reconstruction algorithms, PACS integration, photon-counting hardware, and novel contrast agents are expected to expand the multienergy capability of DECT and further augment its value.


Asunto(s)
Enfermedades Gastrointestinales/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Tracto Gastrointestinal/diagnóstico por imagen , Humanos
9.
Radiographics ; 41(1): 98-119, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33411614

RESUMEN

Dual-energy CT (DECT) is a tremendous innovation in CT technology that allows creation of numerous imaging datasets by enabling discrete acquisitions at more than one energy level. The wide range of images generated from a single DECT acquisition provides several benefits such as improved lesion detection and characterization, superior determination of material composition, reduction in the dose of iodine, and more robust quantification. Technological advances and the proliferation of various processing methods have led to the availability of diverse vendor-based DECT approaches, each with a different acquisition and image reconstruction process. The images generated from various DECT scanners differ from those from conventional single-energy CT because of differences in their acquisition techniques, material decomposition methods, image reconstruction algorithms, and postprocessing methods. DECT images such as virtual monochromatic images, material density images, and virtual unenhanced images have different imaging appearances, texture features, and quantitative capabilities. This heterogeneity creates challenges in their routine interpretation and has certain associated pitfalls. Some artifacts such as residual iodine on virtual unenhanced images and an appearance of pseudopneumatosis in a gas-distended bowel loop on material-density iodine images are specific to DECT, while others such as pseudoenhancement seen on virtual monochromatic images are also observed at single-energy CT. Recognizing the potential pitfalls associated with DECT is necessary for appropriate and accurate interpretation of the results of this increasingly important imaging tool. Online supplemental material is available for this article. ©RSNA, 2021.


Asunto(s)
Yodo , Imagen Radiográfica por Emisión de Doble Fotón , Artefactos , Humanos , Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X
10.
Radiographics ; 41(2): 509-523, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33606565

RESUMEN

Dual-energy CT (DECT) is an exciting innovation in CT technology with profound capabilities to improve diagnosis and add value to patient care. Significant advances in this technology over the past decade have improved our ability to successfully adopt DECT into the clinical routine. To enable effective use of DECT, one must be aware of the pitfalls and artifacts related to this technology. Understanding the underlying technical basis of artifacts and the strategies to mitigate them requires optimization of scan protocols and parameters. The ability of radiologists and technologists to anticipate their occurrence and provide recommendations for proper selection of patients, intravenous and oral contrast media, and scan acquisition parameters is key to obtaining good-quality DECT images. In addition, choosing appropriate reconstruction algorithms such as image kernel, postprocessing parameters, and appropriate display settings is critical for preventing quantitative and qualitative interpretive errors. Therefore, knowledge of the appearances of these artifacts is essential to prevent errors and allows maximization of the potential of DECT. In this review article, the authors aim to provide a comprehensive and practical overview of possible artifacts that may be encountered at DECT across all currently available commercial clinical platforms. They also provide a pictorial overview of the diagnostic pitfalls and outline strategies for mitigating or preventing the occurrence of artifacts, when possible. The broadening scope of DECT applications necessitates up-to-date familiarity with these technologies to realize their full diagnostic potential.


Asunto(s)
Artefactos , Imagen Radiográfica por Emisión de Doble Fotón , Algoritmos , Medios de Contraste , Humanos , Tomografía Computarizada por Rayos X
11.
Radiology ; 297(1): 99-107, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32720868

RESUMEN

Background Limited cathartic preparations for CT colonography with fecal tagging can improve patient comfort but may result in nondiagnostic examinations from poorly tagged stool. Dual-energy CT may overcome this limitation by improving the conspicuity of the contrast agent, but more data are needed. Purpose To investigate whether dual-energy CT improves polyp detection in CT colonography compared with conventional CT at different fecal tagging levels in vitro. Materials and Methods In this HIPAA-compliant study, between December 2017 and August 2019, a colon phantom 30 cm in diameter containing 60 polyps of different shapes (spherical, ellipsoid, flat) and size groups (5-9 mm, 11-15 mm) was constructed and serially filled with simulated feces tagged with four different iodine concentrations (1.26, 2.45, 4.88, and 21.00 mg of iodine per milliliter), then it was scanned with dual-energy CT with and without an outer fat ring to simulate large body size (total diameter, 42 cm). Two readers independently reviewed conventional 120-kVp CT and 40-keV monoenergetic dual-energy CT images to record the presence of polyps and confidence (three-point scale.) Generalized estimating equations were used for sensitivity comparisons between conventional CT and dual-energy CT, and a Wilcoxon signed-rank test was used for reader confidence. Results Dual-energy CT had higher overall sensitivity for polyp detection than conventional CT (58.8%; 95% confidence interval [CI]: 49.7%, 67.3%; 564 of 960 polyps vs 42.1%; 95% CI: 32.1%, 52.8%; 404 of 960 polyps; P < .001), including with the fat ring (48% and 31%, P < .001). Reader confidence improved with dual-energy CT compared with conventional images on all tagging levels (P < .001). Interrater agreement was substantial (κ = 0.74; 95% CI: 0.70, 0.77). Conclusion Compared with conventional 120-kVp CT, dual-energy CT improved polyp detection and reader confidence in a dedicated dual-energy CT colonography phantom, especially with suboptimal fecal tagging. © RSNA, 2020.


Asunto(s)
Pólipos del Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/métodos , Medios de Contraste , Humanos , Fantasmas de Imagen , Imagen Radiográfica por Emisión de Doble Fotón , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
12.
AJR Am J Roentgenol ; 215(3): 610-616, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32755156

RESUMEN

OBJECTIVE. The purpose of this study was to investigate the association between primary pancreatic ductal adenocarcinoma fractional extracellular space (fECS) estimated from pretreatment CT and tumor response to chemotherapy and patient outcome. MATERIALS AND METHODS. A database search identified the records of patients with locally advanced or metastatic pancreatic ductal adenocarcinoma treated with systemic therapies who had undergone pretreatment CT that included both unenhanced and equilibrium phase images. An ROI was placed on the primary tumor and aorta, and the tumor fECS was calculated as follows: (tumor attenuation in the equilibrium phase - tumor attenuation in the unenhanced phase) / (aortic attenuation in the equilibrium phase - aortic attenuation in the unenhanced phase) × (1 - hematocrit). Response to therapy was assessed in subsequent CT examinations according to the Response Evaluation Criteria in Solid Tumors version 1.1. Relevant clinical variables, including carbohydrate antigen 19-9 level, chemotherapy regimen, and survival were recorded. Multivariate analyses were performed to determine the predictors of treatment response and patient survival. RESULTS. The median primary tumor fECS was 0.41 (range, 0.02-0.69). When dichotomized to high (> 0.41) versus low fECS (≤ 0.41) values, a larger proportion of patients with high tumor fECS values achieved disease control after chemotherapy than did those with low tumor fECS values: full cohort, 27 of 30 versus 19 of 30 (p = 0.030); cohort with locally advanced disease, 23 of 24 versus 10 of 15 (p = 0.024). The mean progression-free survival among patients with high primary tumor fECS values was significantly longer than that among those with low fECS values (191 versus 115 days, p = < 0.0001). Primary tumor fECS was an independent predictor of progression-free survival (p = 0.003) in multivariate analysis. CONCLUSION. High primary tumor fECS value estimated from staging CT was associated with chemotherapy response and progression-free survival of patients with advanced pancreatic ductal adenocarcinoma.


Asunto(s)
Carcinoma Ductal Pancreático/diagnóstico por imagen , Espacio Extracelular/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Carcinoma Ductal Pancreático/tratamiento farmacológico , Carcinoma Ductal Pancreático/mortalidad , Carcinoma Ductal Pancreático/patología , Femenino , Humanos , Masculino , Estadificación de Neoplasias , Neoplasias Pancreáticas/tratamiento farmacológico , Neoplasias Pancreáticas/mortalidad , Neoplasias Pancreáticas/patología , Interpretación de Imagen Radiográfica Asistida por Computador , Criterios de Evaluación de Respuesta en Tumores Sólidos , Estudios Retrospectivos , Tasa de Supervivencia , Neoplasias Pancreáticas
13.
AJR Am J Roentgenol ; 212(5): 1037-1043, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30835523

RESUMEN

OBJECTIVE. The objective of our study was to compare the quality of bowel opacification from three different positive oral contrast agents-barium sulfate, diatrizoate, and iohexol-at abdominopelvic CT. MATERIALS AND METHODS. Abdominopelvic CT examinations with three different oral contrast agents (each contrast agent: n = 300 patients) of 900 patients were retrospectively evaluated by two independent readers. For four segments of the gastrointestinal tract (i.e., the stomach, jejunum, ileum, and colon), readers recorded qualitative data (grade of nonuniform lumen opacification, types of inhomogeneous opacifications, presence of artifacts, and distribution of contrast agent) and quantitative data (CT attenuation of lumen [in Hounsfield units]). The results were compared among the three contrast agents using the Mann-Whitney U test and repeated-measures ANOVA with a post hoc Bonferroni correction. RESULTS. Fewer artifacts were detected with iohexol (4.3%) as the oral contrast agent than with diatrizoate (13.0%) and barium sulfate (14.3%) (each, p < 0.05). Barium showed a greater frequency of bowel lumen heterogeneity (388/831 segments, 47%) than iohexol (155/679, 23%) and diatrizoate (185/763, 24% segments) (p < 0.001). Barium showed higher CT attenuation than iohexol and diatrizoate in the stomach but lower CT attenuation in the ileum (each, p < 0.05). CONCLUSION. The frequency of inhomogeneous bowel opacification was lower for iohexol than for diatrizoate or barium sulfate. Barium showed the highest frequency of bowel lumen heterogeneity. The iodinated agents showed greater increases in mean CT attenuation from the proximal bowel segments to the distal bowel segments than barium sulfate.

14.
AJR Am J Roentgenol ; 212(2): 402-410, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30667316

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the sensitivity, tumor conspicuity, and image quality of different material decomposition images of phantoms and patients with nearly isodense bone metastases using rapid-kilovoltage-switching dual-energy CT (DECT). MATERIALS AND METHODS: Fifty-one semianthropomorphic lumbar spine phantoms embedded with 75 simulated tumors were scanned without and with outer torso-attenuating encasement under the same scan settings. Two radiologists independently reviewed the 70-keV virtual monochromatic and material decomposition images (hydroxyapatite-water, water-hydroxyapatite, cortical bone-water, water-cortical bone). The sensitivity of tumor detection, tumor conspicuity (on a 3-point scale), and image quality (on a 3-point scale) were recorded by two independent readers. McNemar and Wilcoxon signed rank tests were used to compare results between the image reconstructions. Six clinical abdominopelvic DECT scans (three men, three women; mean age, 52 years) with nine nearly isodense lumbar spine tumors missed in the clinical report but confirmed on other scans were also evaluated. RESULTS: The hydroxyapatite-water material decomposition algorithm showed improved sensitivity for isodense lesion detection (without torso phantom encasement, 94% vs 82%, p = 0.031; with torso phantom encasement, 38% vs 18%, p = 0.013), and higher tumor conspicuity scores (p < 0.0001) compared with 70-keV virtual monoenergetic images. Artifacts were more prevalent with all material decomposition images than with 70-keV virtual monoenergetic images. Similar results were seen in the patient study. CONCLUSION: Dual-energy CT with hydroxyapatite-water material decomposition may improve the detection of bone marrow metastases, especially for subtle isodense tumors. Further study in prospective clinical scans is warranted.


Asunto(s)
Vértebras Lumbares , Fantasmas de Imagen , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Neoplasias de la Columna Vertebral/secundario , Tomografía Computarizada por Rayos X , Neoplasias de la Médula Ósea/diagnóstico por imagen , Neoplasias de la Médula Ósea/secundario , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen Radiográfica por Emisión de Doble Fotón , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos
16.
Radiology ; 289(1): 103-110, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29969071

RESUMEN

Purpose To compare the CT imaging performance of a carboxybetaine zwitterionic-coated tantalum oxide (TaCZ) nanoparticle CT contrast agent with that of a conventional iodinated contrast agent in a swine model meant to simulate overweight and obese patients. Materials and Methods Four swine were evaluated inside three different-sized adipose-equivalent encasements emulating abdominal girths of 102, 119, and 137 cm. Imaging was performed with a 64-detector row CT scanner at six scan delays after intravenous injection of 240 mg element (Ta or I) per kilogram of body weight of TaCZ or iopromide. For each time point, contrast enhancement of the aorta and liver were measured by using regions of interest. Two readers independently recorded the clarity of vasculature using a five-point Likert scale. Findings were compared by using paired t tests and Wilcoxon signed-rank tests. Results Mean peak enhancement was higher for TaCZ than for iopromide in the aorta (270 HU [σ = 24.5] vs 199 HU [σ = 10.2], P < .001) and liver (61.3 HU [σ = 11.7] vs 45.2 HU [σ = 8], P < .001). Vascular clarity was higher for TaCZ than for iopromide in 63% (132 of 208), 82% (170 of 208), and 86% (178 of 208) of the individual vessels at the 102-, 119-, and 137-cm girths, respectively (P < .01). Arterial clarity scores were higher for TaCZ than for iopromide in 62% (208 of 336) of vessels. Venous clarity scores were higher for TaCZ than for iopromide in 89% (128 of 144) of the veins in the venous phase and in 100% (144 of 144) of veins in the delayed phase (P < .01). No vessel showed higher clarity score with iopromide than with TaCZ. Conclusion An experimental tantalum nanoparticle-based contrast agent showed greater contrast enhancement compared with iopromide in swine models meant to simulate overweight and obese patients. © RSNA, 2018.


Asunto(s)
Medios de Contraste/química , Obesidad/diagnóstico por imagen , Sobrepeso/diagnóstico por imagen , Óxidos/química , Tantalio/química , Tomografía Computarizada por Rayos X/métodos , Animales , Medios de Contraste/administración & dosificación , Modelos Animales de Enfermedad , Femenino , Inyecciones Intravenosas , Nanopartículas/administración & dosificación , Nanopartículas/química , Óxidos/administración & dosificación , Porcinos , Tantalio/administración & dosificación , Circunferencia de la Cintura
17.
AJR Am J Roentgenol ; 211(5): 1010-1019, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30063366

RESUMEN

OBJECTIVE: The purpose of this study is to investigate early changes in 18F-FDG PET/MRI metrics after treatment in patients with advanced pancreatic ductal adenocarcinoma (PDAC) and to correlate those changes with eventual tumor response at standard-of-care CT. SUBJECTS AND METHODS: Thirteen patients with advanced PDAC underwent integrated FDG PET/MRI before and 4 weeks after treatment initiation. Patients were classified as responders or nonresponders according to Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 at subsequent CT performed 8-12 weeks after treatment initiation. Changes in the primary tumor's maximum standardized uptake value (SUVmax), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) determined at PET and apparent diffusion coefficient (ADC) determined at DWI at 4 weeks were compared between responders and nonresponders. RESULTS: Seven patients had a partial response according to RECIST, and six did not. Responders displayed significantly greater decreases in MTV (p = 0.003) and TLG (p = 0.006) in the primary pancreatic tumor at 4 weeks. Responders also displayed a greater increase in the mean (p = 0.004) and minimum (p = 0.024) ADC of the primary tumors. Tumor size change at 4 weeks was not significantly different between responders and nonresponders (p = 0.11). PET responders enjoyed longer progression-free survival (PFS) (p = 0.0004) and overall survival (OS) (p = 0.013) than did nonresponders, using either a 60% reduction in MTV or 65% reduction in TLG as a threshold. MRI responders had significantly longer PFS (p = 0.0002) and OS (p = 0.027) than did nonresponders, using a 20% increase in either mean or minimum ADC as a threshold. CONCLUSION: Integrated PET/MRI can provide early response assessment in patients with advanced PDAC, thus potentially allowing early treatment adaptation in nonresponders.


Asunto(s)
Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma Ductal Pancreático/tratamiento farmacológico , Imagen Multimodal , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/tratamiento farmacológico , Anciano , Carcinoma Ductal Pancreático/patología , Diagnóstico Diferencial , Femenino , Fluorodesoxiglucosa F18 , Humanos , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Neoplasias Pancreáticas/patología , Tomografía de Emisión de Positrones/métodos , Estudios Prospectivos , Radiofármacos , Criterios de Evaluación de Respuesta en Tumores Sólidos , Carga Tumoral
18.
J Comput Assist Tomogr ; 42(3): 459-466, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28937491

RESUMEN

OBJECTIVES: The aim of this study was to compare the accuracy of existing dual-energy computed tomography (CT) angiography coronary artery calcium scoring methods to those obtained using an experimental tungsten-based contrast material and a recently described contrast material extraction process (CMEP). METHODS: Phantom coronary arteries of varied diameters, with different densities and arcs of simulated calcified plaque, were sequentially filled with water, iodine, and tungsten contrast materials and scanned within a thorax phantom at rapid-kVp-switching dual-energy CT. Calcium and contrast density images were obtained by material decomposition (MD) and CMEP. Relative calcium scoring errors among the 4 reconstructed datasets were compared with a ground truth, 120-kVp dataset. RESULTS: Compared with the 120-kVp dataset, tungsten CMEP showed a significantly lower mean absolute error in calcium score (6.2%, P < 0.001) than iodine CMEP, tungsten MD, and iodine MD (9.9%, 15.7%, and 40.8%, respectively). CONCLUSIONS: Novel contrast elements and material separation techniques offer improved coronary artery calcium scoring accuracy and show potential to improve the use of dual-energy CT angiography in a clinical setting.


Asunto(s)
Calcinosis/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Medios de Contraste , Aumento de la Imagen/métodos , Fantasmas de Imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Reproducibilidad de los Resultados
19.
AJR Am J Roentgenol ; 208(1): 114-123, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27786561

RESUMEN

OBJECTIVE: The purpose of this study was to describe the frequency and appearance of beam-hardening artifacts on rapid-kilovoltage-switching dual-energy CT (DECT) image reconstructions of the pelvis. MATERIALS AND METHODS: Monochromatic (70, 52, and 120 keV) and material decomposition CT images (iodine-water and water-iodine) from consecutive pelvic rapid-kilovoltage-switching DECT scans were retrospectively evaluated. We recorded the presence, type (high versus low attenuation), and severity of beam-hardening artifacts (Likert scale from 0, barely seen, to 4, severe), clarity of anatomic delineation (Likert scale from 0, unimpaired, to 4, severely impaired) and SD of CT numbers, iodine and water concentrations, and gray-scale values for artifact-affected regions and corresponding unaffected reference tissue. A pelvic phantom was scanned and evaluated in a similar manner. Wilcoxon signed rank and paired t tests were used to compare results between the image reconstructions. RESULTS: Beam-hardening artifacts were seen in all image reconstructions in all 41 patients (22 men, 19 women; mean age, 57 years; range 22-86 years) who met the inclusion criteria. The median artifact severity score was worse for water-iodine and iodine-water images (score of 3 for each) than for 70-keV (score 1), 52-keV (score 2), and 120-keV (score 1) images (all p < 0.001). The anatomic delineation was worse (p < 0.001) for water-iodine and iodine-water images than for monochromatic images. Higher CT number SD values, material concentrations, and gray-scale values were found for areas affected by artifacts than for reference tissues in all datasets (all p < 0.001). Similar results were seen in the phantom study. CONCLUSION: Beam-hardening artifacts are prevalent in pelvic rapid-kilovoltage-switching DECT and more severe in material decomposition than monochromatic image reconstructions.


Asunto(s)
Algoritmos , Artefactos , Pelvis/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Imagen Radiográfica por Emisión de Doble Fotón/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación
20.
Radiographics ; 37(7): 2063-2082, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29131768

RESUMEN

Abdominal and pelvic hernias may be indolent and detected incidentally, manifest acutely with pain and distress, or cause chronic discomfort. Physical examination findings are often ambiguous and insufficient for optimal triage. Therefore, accurate anatomic delineation and identification of complications are critical for effective treatment planning. Imaging, particularly computed tomography, provides a vital understanding of the hernia's location and size, involved viscera, and severity of associated complications. Reader familiarity with the imaging appearances and anatomic landmarks of hernias is important for correct diagnosis, which may impact preoperative planning and reduce morbidity. This article reviews the appearance of anatomic structures in the abdominal wall and pelvis that are important for diagnosing common and uncommon abdominal and pelvic hernias, and it highlights key imaging features that are helpful for differentiating hernias, mimics, and their complications. Online DICOM image stacks are available for this article . ©RSNA, 2017.


Asunto(s)
Hernia/diagnóstico por imagen , Puntos Anatómicos de Referencia , Diagnóstico Diferencial , Humanos , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Ultrasonografía
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda