Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biomed Opt Express ; 9(6): 2785-2809, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30258691

RESUMO

The dynamic response behavior of red blood cells holds the key to understanding red blood cell related diseases. In this regard, an understanding of the physiological functions of erythrocytes is significant before focusing on red blood cell aggregation in the microcirculatory system. In this work, we present a theoretical model for a photoacoustic signal that occurs when deformed red blood cells pass through a microfluidic channel. Using a Green's function approach, the photoacoustic pressure wave is obtained analytically by solving a combined Navier-Stokes and photoacoustic equation system. The photoacoustic wave expression includes determinant parameters for the cell deformability such as plasma viscosity, density, and red blood cell aggregation, as well as involving laser parameters such as beamwidth, pulse duration, and repetition rate. The effects of aggregation on blood rheology are also investigated. The results presented by this study show good agreements with the experimental ones in the literature. The comprehensive analytical solution of the extended photoacoustic transport model including a modified Morse type potential function sheds light on the dynamics of aggregate formation and demonstrates that the profile of a photoacoustic pressure wave has the potential for detecting and characterizing red blood cell aggregation.

2.
Biomed Opt Express ; 9(4): 1423-1444, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29675293

RESUMO

Spectrally constrained diffuse optical tomography (SCDOT) is known to improve reconstruction in diffuse optical imaging; constraining the reconstruction by coupling the optical properties across multiple wavelengths suppresses artefacts in the resulting reconstructed images. In other work, L1-norm regularization has been shown to improve certain types of image reconstruction problems as its sparsity-promoting properties render it robust against noise and enable the preservation of edges in images, but because the L1-norm is non-differentiable, it is not always simple to implement. In this work, we show how to incorporate L1 regularization into SCDOT. Three popular algorithms for L1 regularization are assessed for application in SCDOT: iteratively reweighted least square algorithm (IRLS), alternating directional method of multipliers (ADMM), and fast iterative shrinkage-thresholding algorithm (FISTA). We introduce an objective procedure for determining the regularization parameter in these algorithms and compare their performance in simulated experiments, and in real data acquired from a tissue phantom. Our results show that L1 regularization consistently outperforms Tikhonov regularization in this application, particularly in the presence of noise.

3.
Biomed Opt Express ; 9(1): 131-141, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29359092

RESUMO

Noninvasive, direct measurement of local muscle blood flow in humans remains limited. Diffuse correlation spectroscopy (DCS) is an emerging technique to measure regional blood flow at the microvascular level. In order to better understand the strengths and limitations of this novel technique, we performed a validation study by comparing muscle blood flow changes measured with DCS and Doppler ultrasound during exercise. Nine subjects were measured (all males, 27.4 ± 2.9 years of age) for a rhythmic handgrip exercise at 20% and 50% of individual maximum voluntary contraction (MVC), followed by a post-exercise recovery. The results from DCS and Doppler ultrasound were highly correlated (R = 0.99 ± 0.02). DCS was more reliable and less susceptible to motion artifact.

4.
Biomed Opt Express ; 9(2): 569-580, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29552394

RESUMO

Reliable, continuous and noninvasive blood flow and hemoglobin monitoring in trauma patients remains a critical, but generally unachieved goal. Two optical sensing methods - diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy (DRS) - are used to monitor and detect internal hemorrhage. Specifically, we investigate if cutaneous perfusion measurements acquired using DCS and DRS in peripheral (thighs and ear-lobe) tissues could detect severe hemorrhagic shock in a porcine model. Four animals underwent high-grade hepato-portal injury in a closed abdomen, to induce uncontrolled hemorrhage and were subsequently allowed to bleed for 10 minutes before fluid resuscitation. DRS and DCS measurements of cutaneous blood flow were acquired using fiber optical probes placed on the thigh and earlobe of the animals and were obtained repeatedly starting from 1 to 5 minutes pre-injury, up to several minutes post shock. Clear changes were observed in measured optical spectra across all animals at both sites. DCS-derived cutaneous blood flow decreased sharply during hemorrhage, while DRS-derived vascular saturation and hemoglobin paralleled cardiac output. All derived optical parameters had the steepest changes during the rapid initial hemorrhage unambiguously. This suggests that a combined DCS and DRS based device might provide an easy-to-use, non-invasive, internal-hemorrhage detection system that can be used across a wide array of clinical settings.

5.
Biomed Opt Express ; 9(2): 743-754, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29552409

RESUMO

Albumin-derived perfluorocarbon-based capsules are promising as artificial oxygen carriers with high solubility. However, these capsules have to be studied further to allow initial human clinical tests. The aim of this paper is to provide and characterize a holographic optical tweezer to enable contactless trapping and moving of individual capsules in an environment that mimics physiological (in vivo) conditions most effectively in order to learn more about the artificial oxygen carrier behavior in blood plasma without recourse to animal experiments. Therefore, the motion behavior of capsules in a ring shaped or vortex beam is analyzed and optimized on account of determination of the optical forces in radial and axial direction. In addition, due to the customization and generation of dynamic phase holograms, the optical tweezer is used for first investigations on the aggregation behavior of the capsules and a statistical evaluation of the bonding in dependency of different capsule sizes is performed. The results show that the optical tweezer is sufficient for studying individual perfluorocarbon-based capsules and provide information about the interaction of these capsules for future use as artificial oxygen carriers.

6.
Biomed Opt Express ; 9(3): 1256-1261, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29541518

RESUMO

Optical tweezers are proven indispensable single-cell micro-manipulation and mechanical phenotyping tools. In this study, we have used optical tweezers for measuring the viscoelastic properties of human red blood cells (RBCs). Comparison of the viscoelastic features of the healthy fresh and atorvastatin treated cells revealed that the drug softens the cells. Using a simple modeling approach, we proposed a molecular model that explains the drug-induced softening of the RBC membrane. Our results suggest that direct interactions between the drug and cytoskeletal components underlie the drug-induced softening of the cells.

7.
Biomed Opt Express ; 9(5): 2383-2393, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29760995

RESUMO

Direct intravital imaging of an endothelial surface layer (ESL) in pulmonary microcirculation could be a valuable approach to investigate the role of a vascular endothelial barrier in various pathological conditions. Despite its importance as a marker of endothelial cell damage and impairment of the vascular system, in vivo visualization of ESL has remained a challenging technical issue. In this work, we implemented a pulmonary microcirculation imaging system integrated to a custom-design video-rate laser scanning confocal microscopy platform. Using the system, a real-time cellular-level microscopic imaging of the lung was successfully performed, which facilitated a clear identification of individual flowing erythrocytes in pulmonary capillaries. Subcellular level pulmonary ESL was identified in vivo by fluorescence angiography using a dextran conjugated fluorophore to label blood plasma and the red blood cell (RBC) exclusion imaging analysis. Degradation of ESL width was directly evaluated in a murine sepsis model in vivo, suggesting an impairment of pulmonary vascular endothelium and endothelial barrier dysfunction.

8.
Biomed Opt Express ; 8(10): 4310-4315, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29082066

RESUMO

Originally described in crane-fly spermatocytes, tethers physically link and transmit force between the ends of separating chromosomes. Optical tweezers and laser scissors were used to sever the tether between chromosomes, create chromosome fragments attached to the tether which move toward the opposite pole, and to trap the tethered fragments. Laser microsurgery in the intracellular space between separating telomeres reduced chromosome strain in half of tested chromosome pairs. When the telomere-containing region was severed from the rest of the chromosome body, the resultant fragment either traveled towards the proper pole (poleward), towards the sister pole (cross-polar), or movement ceased. Fragment travel towards the sister pole varied in distance and always ceased following a cut between telomeres, indicating the tether is responsible for transferring a cross-polar force to the fragment. Optical trapping of cross-polar traveling fragments places an upper boundary on the tethering force of ~1.5 pN.

9.
Biomed Opt Express ; 8(9): 4200-4205, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28966858

RESUMO

Successful artificial insemination relies on the use of high quality spermatozoa. One measure of sperm quality is swimming force. Increased swimming force has been correlated with higher sperm swimming speeds and improved reproductive success. It is hypothesized that by increasing sperm swimming speed, one can increase swimming force. Previous studies have shown that red light irradiation causes an increase in sperm swimming speed. In the current study, 633nm red light irradiation is shown to increase mean squared displacement in trapped sperm. The methodology allows for comparison of relative swimming forces between irradiated and non-irradiated samples.

10.
Biomed Opt Express ; 8(1): 384-394, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28101425

RESUMO

The elasticity of red cell membrane is a critical physiological index for the activity of RBC. Study of the inherent mechanism for RBCs membrane elasticity transformation is attention-getting all along. This paper proposes an optimized measurement method of erythrocytes membrane shear modulus incorporating acousto-optic deflector (AOD) scanning optical tweezers system. By use of this method, both membrane shear moduli and sizes of RBCs with different in vitro times were determined. The experimental results reveal that the RBCs membrane elasticity and size decline with in vitro time extension. In addition, semi quantitative measurements of S-nitrosothiol content in blood using fluorescent spectrometry during in vitro storage show that RBCs membrane elasticity change is positively associated with the S-nitrosylation level of blood. The analysis considered that the diminished activity of the nitric oxide synthase makes the S-nitrosylation of in vitro blood weaker gradually. The main reason for worse elasticity of the in vitro RBCs is that S-nitrosylation effect of spectrin fades. These results will provide a guideline for further study of in vitro cells activity and other clinical applications.

11.
Biomed Opt Express ; 8(10): 4504-4513, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29082080

RESUMO

Third harmonic generation (THG) microscopy can exploit endogenous harmonophores such as pigment macromolecules for enhanced image contrast, and therefore can be used without exogenous contrast agents. Previous studies have established that carotenoid compounds are ideal harmonophores for THG microscopy; we therefore sought to determine whether THG from endogenous carotenoid-derived compounds, such as retinal in photoreceptor cells, could serve as a new label-free method for developmental studies. Here we study the development of the pupal eye in Drosophila melanogaster and determine the localization of rhodopsin using THG microscopy technique. Additionally, by altering the chromophore or the opsin protein we were able to detect changes in both the retinal distribution morphology and in THG intensity age-dependent profiles. These results demonstrate that THG microscopy can be used to detect altered photoreceptor development and may be useful in clinically relevant conditions associated with photoreceptor degeneration.

12.
Biomed Opt Express ; 8(10): 4756-4771, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29082100

RESUMO

Laser-exposed plasmonic substrates permeabilize the plasma membrane of cells when in close contact to deliver cell-impermeable cargo. While studies have determined the cargo delivery efficiency and viability of laser-exposed plasmonic substrates, morphological changes in a cell have not been quantified. We porated myoblast C2C12 cells on a plasmonic pyramid array using a 532-nm laser with 850-ps pulse length and time-lapse fluorescence imaging to quantify cellular changes. We obtain a poration efficiency of 80%, viability of 90%, and a pore radius of 20 nm. We quantified area changes in the plasma membrane attached to the substrate (10% decrease), nucleus (5 - 10% decrease), and cytoplasm (5 - 10% decrease) over 1 h after laser treatment. Cytoskeleton fibers show a change of 50% in the alignment, or coherency, of fibers, which stabilizes after 10 mins. We investigate structural and morphological changes due to the poration process to enable the safe development of this technique for therapeutic applications.

13.
Biomed Opt Express ; 8(7): 3343-3359, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28717571

RESUMO

We present a novel extended-focus optical coherence microscope (OCM) attaining 0.7 µm axial and 0.4 µm lateral resolution maintained over a depth of 40 µm, while preserving the advantages of Fourier domain OCM. Our system uses an ultra-broad spectrum from a supercontinuum laser source. As the spectrum spans from near-infrared to visible wavelengths (240 nm in bandwidth), we call the system visOCM. The combination of such a broad spectrum with a high-NA objective creates an almost isotropic 3D submicron resolution. We analyze the imaging performance of visOCM on microbead samples and demonstrate its image quality on cell cultures and ex-vivo brain tissue of both healthy and alzheimeric mice. In addition to neuronal cell bodies, fibers and plaques, visOCM imaging of brain tissue reveals fine vascular structures and sub-cellular features through its high spatial resolution. Sub-cellular structures were also observed in live cells and were further revealed through a protocol traditionally used for OCT angiography.

14.
Biomed Opt Express ; 8(1): 177-192, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28101410

RESUMO

Can photothermal gold nanoparticle mediated laser manipulation be applied to induce cardiac contraction? Based on our previous work, we present a novel concept of cell stimulation. A 532 nm picosecond laser was employed to heat gold nanoparticles on cardiomyocytes. This leads to calcium oscillations in the HL-1 cardiomyocyte cell line. As calcium is connected to the contractility, we aimed to alter the contraction rate of native and stem cell derived cardiomyocytes. A contraction rate increase was particularly observed in calcium containing buffer with neonatal rat cardiomyocytes. Consequently, the study provides conceptual ideas for a light based, nanoparticle mediated stimulation system.

15.
Biomed Opt Express ; 8(10): 4369-4379, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29082071

RESUMO

The ability to record neural activity in the brain of a living organism at cellular resolution is of great importance for defining the neural circuit mechanisms that direct behavior. Here we present an adaptive two-photon microscope optimized for extraction of neural signals over volumes in intact Drosophila brains, even in the presence of specimen motion. High speed volume imaging was made possible through reduction of spatial resolution while maintaining the light collection efficiency of a high resolution, high numerical aperture microscope. This enabled simultaneous recording of odor-evoked calcium transients in a defined volume of mushroom body Kenyon cell bodies in a live fruit fly.

16.
Biomed Opt Express ; 8(10): 4419-4426, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29082074

RESUMO

Deterioration in mitochondrial function leads to hepatic ischemia and reperfusion injury (IRI) in liver surgery and transplantation. 3D optical cryoimaging was used to measure the levels of mitochondrial coenzymes NADH and FAD, and their redox ratio (NADH/FAD) gave a quantitative marker for hepatocyte oxidative stress during IRI. Using a rat model, five groups were compared: control, ischemia for 60 or 90 minutes (Isc60, Isc90), ischemia for 60 or 90 minutes followed by reperfusion of 24 hours (IRI60, IRI90). Ischemia alone did not cause a significant increase in the redox ratio; however, the redox ratio in both IRI60 and IRI90 groups was significantly decreased by 29% and 71%, respectively. A significant correlation was observed between the redox ratio and other markers of injury such as serum aminotransferase levels and the tissue ATP level. The mitochondrial redox state can be successfully measured using optical cryoimaging as a quantitative marker of hepatic IR injury.

17.
Biomed Opt Express ; 8(7): 3383-3394, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28717574

RESUMO

In this study, a sensitive fluorescence sensor was developed for the detection of small, fluorescence-labeled particles dispersed in a solution. The prototype system comprises of a laser confocal optical system and a mechanical sample stage to detect photon bursting of fluorescence-labeled small particles in sample volumes less than 5 µL within 3 minutes. To examine the feasibility of the prototype system as a diagnostic tool, assemblages of rotavirus and fluorescence-labeled antibody were analyzed. The detection sensitivity for rotavirus was 1 × 104 pfu/mL. Rotavirus in stool samples from patients with acute gastroenteritis was also detected. The advantages and disadvantages of this immunosensor with respect to ELISA and RT-PCR, the current gold standards for virus detection, are discussed.

18.
Biomed Opt Express ; 8(7): 3395-3403, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28717575

RESUMO

Label-free multispectral optoacoustic tomography (MSOT) has recently shown superior performance in visualizing the morphology of human vasculature, especially of smaller vessels, compared to ultrasonography. Herein, we extend these observations towards MSOT interrogation of macrovascular endothelial function. We employed a real-time handheld MSOT scanner to assess flow-mediated dilatation (FMD), a technique used to characterize endothelial function. A data processing scheme was developed to quantify the dimensions and diameter changes of arteries in humans and determine wall distensibility parameters. By enabling high-resolution delineation of the blood-vessel wall in a cross-sectional fashion, the findings suggest MSOT as a capable alternative to ultrasonography for clinical FMD measurements.

19.
Biomed Opt Express ; 8(11): 4974-4986, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29188095

RESUMO

Corneal lamellar cutting with a blade or femtosecond laser (FSL) is commonly used during refractive surgery and corneal grafts. Surface roughness of the cutting plane influences postoperative visual acuity but is difficult to assess reliably. For the first time, we compared chromatic confocal microscopy (CCM) with scanning electron microscopy, atomic force microscopy (AFM) and focus-variation microscopy (FVM) to characterize surfaces of variable roughness after FSL cutting. The small area allowed by AFM hinders conclusive roughness analysis, especially with irregular cuts. FVM does not always differentiate between smooth and rough surfaces. Finally, CCM allows analysis of large surfaces and differentiates between surface states.

20.
Biomed Opt Express ; 7(1): 93-8, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26819820

RESUMO

Determining the survival rate of avian embryos during incubation is essential for cost-saving in the poultry industry. A multi-channel diffuse speckle contrast analysis (DSCA) system, comprising four optical fiber channels, is proposed to achieve noninvasive in vivo measurements of deep tissue flow. The system was able to monitor chick embryo vital signs over the entire incubation period. Moreover, it proved useful in distinguishing between chick embryos in healthy and weakened conditions.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa