Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Magn Reson Imaging ; 13(8): 1095-8, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8750321

RESUMO

Within the last several years a number of technical developments have been made in magnetic resonance imaging (MRI) that can potentially impact clinical and research MR imaging application in epilepsy. These include developments in instrumentation and in pulse sequences. Advances in instrumentation include higher capacity gradient systems and multiple receiver coils as directed to brain imaging. Advances in pulse sequence include use of fast or turbo-spin-echo techniques, variants of echo-planar imaging, and sequences such as fluid-attenuation inversion recovery (FLAIR) targeted to specific applications of brain imaging. The purpose of this paper is to review several of these developments.


Assuntos
Epilepsia/diagnóstico , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Encéfalo/patologia , Imagem Ecoplanar/instrumentação , Epilepsia/patologia , Humanos , Imagem Cinética por Ressonância Magnética/instrumentação
2.
Neurogastroenterol Motil ; 23(7): 617-e252, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21470342

RESUMO

BACKGROUND: The mechanisms of 'idiopathic' rapid gastric emptying, which are associated with functional dyspepsia and functional diarrhea, are not understood. Our hypotheses were that increased gastric motility and reduced postprandial gastric accommodation contribute to rapid gastric emptying. METHODS: Fasting and postprandial (300kcal nutrient meal) gastric volumes were measured by magnetic resonance imaging (MRI) in 20 healthy people and 17 with functional dyspepsia; seven had normal and 10 had rapid gastric emptying. In 17 healthy people and patients, contractility was analyzed by spectral analysis of a time-series of gastric cross-sectional areas. Logistic regression models analyzed whether contractile parameters, fasting volume, and postprandial volume change could discriminate between health and patients with normal or rapid gastric emptying. KEY RESULTS: While upper gastrointestinal symptoms were comparable, patients with rapid emptying had a higher (P=0.002) body mass index than normal gastric emptying. MRI visualized propagating contractions at ∼3cpm in healthy people and patients. Compared with controls (0.32±0.04, Mean±SEM), the amplitude of gastric contractions in the entire stomach was higher (OR 4.1, 95% CI 1.2-14.0) in patients with rapid (0.48±0.06), but not normal gastric emptying (0.20±0.06). Similar differences were observed in the distal stomach. However, the propagation velocity, fasting gastric volume, and the postprandial volume change were not significantly different between patients and controls. CONCLUSIONS & INFERENCES: MRI provides a non-invasive and refined assessment of gastric volumes and contractility in humans. Increased gastric contractility may contribute to rapid gastric emptying in functional dyspepsia.


Assuntos
Dispepsia/fisiopatologia , Esvaziamento Gástrico/fisiologia , Motilidade Gastrointestinal/fisiologia , Estômago/fisiopatologia , Adulto , Estudos de Casos e Controles , Dispepsia/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Contração Muscular/fisiologia , Tamanho do Órgão , Período Pós-Prandial , Análise de Regressão , Estômago/patologia
3.
Magn Reson Med ; 55(5): 1175-9, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16528708

RESUMO

Magnetic resonance elastography (MRE) is capable of quantitatively depicting the mechanical properties of tissues in vivo. In contrast to mechanical excitation at the surface of the tissue, the method proposed in this study describes shear waves produced by an inserted needle. The results demonstrate that MRE performed with the needle driver provides shear stiffness estimates that correlate well with those obtained using mechanical testing. Comparisons between MRE acquisitions obtained with surface and needle drivers yielded similar results in general. However, the well-defined wave propagation pattern provided by the needle driver in a target region can reduce section orientation-related error in wavelength estimation that occurs with surface drivers in 2D MRE acquisitions. Preliminary testing of the device was performed on animals. This study demonstrates that the needle driver is an effective option that offers advantages over surface drivers for obtaining accurate stiffness estimates in targeted regions that are accessible by the needle.


Assuntos
Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/fisiologia , Estimulação Física/instrumentação , Animais , Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Masculino , Palpação , Estimulação Física/métodos , Coelhos , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico
4.
Radiology ; 198(1): 55-60, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8539406

RESUMO

PURPOSE: To test the hypothesis that respiration effects in three-dimensional (3D) coronary magnetic resonance (MR) imaging can be reduced with navigator-echo-based gating or triggering according to the superior-inferior position of the diaphragm. MATERIALS AND METHODS: Real-time respiratory gating and respiratory triggering (breath hold with feedback) were implemented with navigator echoes in a magnetization-prepared, segmented, 3D coronary imaging sequence. The two techniques were first tested with a motion phantom. An imaging protocol that compared real-time respiratory-gated acquisition, real-time respiratory-triggered acquisition, and continuous acquisition was then evaluated in six healthy subjects. RESULTS: Real-time respiratory-gated and respiratory-triggered acquisition were superior to continuous acquisition with two signals averaged (P = .025). The performance of the gated acquisition was about the same as that of the triggered acquisition (P = .05). CONCLUSION: Navigator-echo-based, real-time respiratory-gating and respiratory-triggering techniques are practical methods for effective reduction of respiration effects in coronary MR imaging.


Assuntos
Vasos Coronários/anatomia & histologia , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Respiração , Adulto , Artefatos , Eletrocardiografia , Frequência Cardíaca , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Imagens de Fantasmas
5.
Radiology ; 180(2): 551-6, 1991 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-2068326

RESUMO

Use of intraacquisition modification of pulse-sequence parameters to reduce acquisition time for conventional T2-weighted spin-echo images was evaluated. With this technique (variable-rate spin-echo pulse sequence), the repetition time and echo time (TR msec/TE msec) were reduced during imaging as a function of the phase-encoding view. To maintain T2-based contrast, TR and TE for the low-spatial-frequency views were left at their prescribed values (eg, 2,000/80). TR and TE for the high-spatial-frequency views were progressively reduced during imaging (eg, to 1,000/20). Acquisition time was reduced by as much as 25%. In one pulse sequence, the duration of multisection imaging nominally performed at TR 2,000 and with 256 phase-encoding views was reduced from 9 minutes 30 seconds to 6 minutes 30 seconds. In all sequences, edges and small structures were enhanced, and T2 contrast was somewhat decreased in high spatial frequencies. Filtering of the raw data before reconstruction can suppress these effects and provide a net increase in contrast-to-noise ratio.


Assuntos
Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Encéfalo/anatomia & histologia , Meios de Contraste , Humanos , Articulação do Joelho/anatomia & histologia , Ciência de Laboratório Médico , Modelos Teóricos , Fatores de Tempo
6.
Radiology ; 189(1): 259-64, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8396785

RESUMO

PURPOSE: A multisection, whole-body echo-planar imaging (EPI) sequence was developed to obtain T2-weighted images of the liver in one 18-second breath hold with a standard magnetic resonance (MR) imaging system. MATERIALS AND METHODS: This capability was achieved by dividing the data acquisition period into eight interleaved segments rather than one or two as implemented previously with EPI systems having high-power gradient subsystems. RESULTS: The interleaved echo-planar images had excellent depiction of anatomy and no identifiable respiratory artifact. In 26 lesions in 12 patients, the eight-shot echo-planar images (2,000/66 [repetition time msec/echo time msec]) had superior contrast compared with conventional T2-weighted spin-echo (SE) images (2,500/60) by an average factor of 1.22 +/- 0.31 (standard deviation) and an average contrast-to-noise ratio relative to conventional T2-weighted SE images of 0.85 +/- 0.22. CONCLUSION: With a conventional MR imaging system, breath-hold T2-weighted echo-planar images of the liver are comparable in diagnostic quality to conventional T2-weighted SE images.


Assuntos
Imagem Ecoplanar , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Adenoma de Células das Ilhotas Pancreáticas/diagnóstico , Adenoma de Células das Ilhotas Pancreáticas/secundário , Adulto , Idoso , Ar , Tumor Carcinoide/diagnóstico , Tumor Carcinoide/secundário , Cobre , Sulfato de Cobre , Imagem Ecoplanar/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Modelos Estruturais , Respiração , Fatores de Tempo
7.
Magn Reson Med ; 26(2): 361-7, 1992 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-1513257

RESUMO

We have investigated the properties of a recursive process in which the output signal from a given RF excitation pulse may be used as the input (excitation) pulse of a subsequent iteration. This recursive excitation technique increases contrast and improves feature segmentation for the purpose of motion tracking.


Assuntos
Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Ágar , Cobre , Sulfato de Cobre , Transferência de Energia , Humanos , Perna (Membro)/anatomia & histologia , Modelos Estruturais , Modelos Teóricos , Movimento (Física) , Água
8.
Magn Reson Med ; 36(1): 117-23, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8795030

RESUMO

Algorithms to reliably detect motion in navigator echoes are crucial to many MRI motion suppression techniques. The accuracy of these algorithms is affected by noise and deformation of navigator echo profile caused by physiologic motion. This study compared the performance of algorithms based on correlation and least squares for extracting displacement information from motion-monitoring navigator echoes, using computer simulation and in vivo imaging. The least squares algorithm was determined to be of higher accuracy than the correlation algorithm against errors caused by noise and profile deformation.


Assuntos
Algoritmos , Artefatos , Imageamento por Ressonância Magnética , Encéfalo/anatomia & histologia , Simulação por Computador , Diafragma/anatomia & histologia , Diafragma/fisiologia , Humanos , Aumento da Imagem/métodos , Análise dos Mínimos Quadrados , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Nariz/anatomia & histologia , Respiração
9.
Magn Reson Med ; 38(4): 678-86, 1997 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9324336

RESUMO

Ghosting in MRI due to modulation of k-space data can be caused by motion of the subject or characteristics of the sequence. A general solution for 2DFT MRI that reduces ghosting without causal modeling is presented. Separate image data sets are acquired in which the phase and frequency directions are swapped. In these two data sets, the image signal is correlated, whereas the ghost signals are not. By taking a correlation of these two data sets, an image with greatly reduced ghosting is obtained. The reduction is shown to depend both on the correct signal intensity of the image, as well as the ghost intensity in the ghosted region. The reduction approaches 100% in regions of low image signal, and is more moderate in regions of higher image signal. The process was applied to conventional spin-echo, fast-spin-echo, and gradient echo imaging of volunteers and a phantom. Results of a reader study of the volunteer images reflected a significant overall reduction of ghosting artifacts in all volunteer experiments.


Assuntos
Artefatos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética , Abdome/anatomia & histologia , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Modelos Teóricos , Imagens de Fantasmas , Tórax/anatomia & histologia
10.
Magn Reson Med ; 23(1): 172-8, 1992 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-1531152

RESUMO

Despite the fact that respiratory motion is a major factor limiting the image quality of MR examinations in the upper abdomen, little quantitative information is available about the kinematics of visceral motion during respiration. The objective of this study was to obtain a measure of the relative longitudinal and transverse displacements of the upper abdominal organs during breathing using an MR line scan technique.


Assuntos
Abdome/fisiologia , Imageamento por Ressonância Magnética , Mecânica Respiratória/fisiologia , Músculos Abdominais/fisiologia , Diafragma/fisiologia , Análise de Fourier , Humanos , Fígado/fisiologia , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Movimento , Respiração/fisiologia
11.
Magn Reson Med ; 30(4): 507-11, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8255201

RESUMO

A technique is described that provides improved reproducibility of breath-holding for MR image acquisition by monitoring the superior-inferior (S/I) position of the diaphragm. The method incorporates detection of the level of inspiration using an MR signal, rapid display to the patient of diaphragm position to enable breath-hold adjustment, and triggering of image data acquisition once appropriate position is attained. The response time of the system is short, approximately 10 ms. Studies in six volunteers using this method demonstrate a considerable decrease in the S/I range of diaphragm position over 10 consecutive periods of suspended respiration. The mean range is 1.3 mm with the system, while it is 8.3 mm without using it. It is expected that this method will be of assistance in many abdominal and cardiothoracic studies that use breath-hold techniques.


Assuntos
Imageamento por Ressonância Magnética/métodos , Monitorização Fisiológica/métodos , Respiração , Retroalimentação , Humanos
12.
Magn Reson Med ; 34(1): 11-6, 1995 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7674888

RESUMO

To reduce respiratory blur and ghosts in 3D coronary imaging, a data acquisition scheme using consistent multiple breath-holds was implemented. A navigator echo was acquired and processed in real time to dynamically measure diaphragm position. This information was provided as a visual prompt to the patient to maintain consistency in breath-hold levels such that the variation range of diastolic heart position was less than 2 mm. Preliminary results indicate that this multiple breath-hold acquisition scheme, compared with acquisition under respiration, can significantly reduce blur and ghost artifacts in 3D coronary imaging.


Assuntos
Artefatos , Vasos Coronários/anatomia & histologia , Processamento de Imagem Assistida por Computador , Angiografia por Ressonância Magnética/métodos , Monitorização Fisiológica/métodos , Respiração , Adulto , Eletrocardiografia , Retroalimentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
Magn Reson Med ; 36(4): 579-87, 1996 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8892211

RESUMO

An ECG-triggered magnetization-prepared segmented 3D fast gradient echo sequence was developed to perform pulmonary arterial MR angiography. A selective inversion recovery pulse was used in the magnetization preparation to suppress venous vasculature. A real-time gating technique based on navigator echoes was implemented to reduce respiration effects. Pencil-beam navigator echoes were acquired immediately before and after the readout train and processed in real-time to dynamically measure the diaphragm position, which was used to control data acquisition with an accept-or-reject-reacquire logic. In a study of 10 volunteers, a gated 3D acquisition with 28 slices required on average approximately 4 min of acquisition time, and six to seven segmental arteries related to the interlobar trunk of the pulmonary artery were depicted. The use of SIR pulse reduced venous signal by 99%. The gated acquisitions were superior to the ungated acquisitions (n = 10, P < 0.005). The real-time navigator gating technique is effective for reduction of respiration effects and thereby makes high resolution 3D MRA of the pulmonary arteries feasible.


Assuntos
Pulmão/patologia , Angiografia por Ressonância Magnética/métodos , Artéria Pulmonar/anatomia & histologia , Algoritmos , Eletrocardiografia , Humanos , Respiração
14.
Radiology ; 215(3): 904-9, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10831720

RESUMO

A technique for automatic retrospective correction of motion artifacts on magnetic resonance (MR) images was developed that uses only the raw (complex) data from the MR imager and requires no knowledge of patient motion during the acquisition. The algorithm was tested on coronal images of the rotator cuff in a series of 144 patients, and the improvements in image quality were similar to those achieved with navigator echoes. The results demonstrate that autocorrection can significantly reduce motion artifacts in a technically demanding MR imaging application.


Assuntos
Imageamento por Ressonância Magnética/métodos , Algoritmos , Artefatos , Humanos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Movimento , Ombro/patologia , Estatísticas não Paramétricas , Fatores de Tempo
15.
Magn Reson Med ; 43(3): 459-69, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10725890

RESUMO

Corruption of the image time series due to interimage head motion limits the clinical utility of functional MRI. This paper presents a method for real-time prospective correction of rotation and translation in all six degrees of rigid body motion. By incorporating an orbital navigator (ONAV) echo for each of the sagittal, axial, and coronal planes into the fMRI pulse sequence, rotation and translation can be measured and the spatial orientation of the image acquisition sequence that follows can be corrected prospectively in as little as 160 msec. Testing of the method using a computerized motion phantom capable of performing complex multiaxial motion showed subdegree rotational and submillimeter translational accuracy over a range of +/-8 degrees and +/-8 mm of motion. In vivo images demonstrate correction of simultaneous through-plane and in-plane motion and improved detection of fMRI activation in the presence of head motion.


Assuntos
Movimentos da Cabeça , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Artefatos , Encéfalo/anatomia & histologia , Encéfalo/fisiologia , Humanos , Imagens de Fantasmas , Rotação , Processamento de Sinais Assistido por Computador
16.
Radiology ; 205(2): 541-5, 1997 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9356642

RESUMO

PURPOSE: To evaluate an adaptive-motion-correction technique to reduce global motion in shoulder magnetic resonance (MR) images. MATERIALS AND METHODS: In the adaptive-motion-correction technique, interleaved navigator echoes are used to provide a measure of view-to-view displacement along the craniocaudal direction for each image echo in the acquisition. The information is then retrospectively applied to the k-space data to correct for global shoulder motion. This algorithm was evaluated in a series of 143 consecutive patient shoulder examinations by comparing the original image set for each patient with the same image set after retrospective correction by means of this algorithm. RESULTS: The average amplitude of craniocaudal motion was 1.4 mm. Image degradation due to motion was apparent in 100 (70%) of the 143 examinations. Application of the adaptive-motion-correction technique improved image quality in 73 (73%) of these 100 examinations or 51% of all 143 examinations. CONCLUSION: Adaptive motion correction improved image quality in approximately three-quarters of the examinations in which motion was present.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Articulação do Ombro/fisiologia , Humanos , Movimento , Articulação do Ombro/anatomia & histologia
17.
Magn Reson Med ; 14(3): 547-53, 1990 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-2355836

RESUMO

We describe a system for performing interactive MRI in real time. Using a TR/TE 7.1/3.5 ms sequence, the operator may alter a scan parameter and observe the effects of the alteration on the image within a few hundred milliseconds. With this system, we can interactively control the oblique scan slice orientation and, using inversion pulses, the image contrast.


Assuntos
Imageamento por Ressonância Magnética/métodos , Fluoroscopia , Humanos
18.
J Magn Reson Imaging ; 6(2): 356-62, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-9132102

RESUMO

The purpose of this paper was to develop and evaluate a fast inversion recovery (FIR) technique for T1-weighted MR imaging of contrast-enhancing brain pathology. The FIR technique was developed, capable of imaging 24 sections in approximately 7 minutes using two echoes per repetition and an alternating echo phase encoding assignment. Resulting images were compared with conventional T1-weighted spin echo (T1SE) images in 18 consecutive patients. Compared with corresponding T1SE images, FIR images were quantitatively comparable or superior for lesion-to-background contrast and contrast-to-noise ratio (CNR). Gray-to-white matter and cerebrospinal fluid (CSF)-to-white matter contrast and CNR were statistically superior in FIR images. Qualitatively, the FIR technique provided comparable lesion detection, improved lesion conspicuity, and superior image contrast compared with T1SE images. Although FIR images had greater amounts of image artifacts, there was not a statistically increased amount of interpretation-interfering image artifact. FIR provides T1-weighted images that are superior to T1SE images for a number of image quality criteria.


Assuntos
Encefalopatias/diagnóstico , Neoplasias Encefálicas/diagnóstico , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Artefatos , Neoplasias Encefálicas/secundário , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Fatores de Tempo
19.
Radiology ; 193(1): 173-80, 1994 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8090888

RESUMO

PURPOSE: To evaluate fast fluid-attenuated inversion-recovery (FLAIR) technique for imaging brain abnormalities. MATERIALS AND METHODS: A fast FLAIR sequence was developed that provided 36 5-mm contiguous sections in 5 minutes 8 seconds. Resulting images were compared with dual-echo T2-weighted spin-echo images of 41 consecutive patients with brain abnormalities. RESULTS: Contrast and contrast-to-noise ratios (C/Ns) (for contrast between the lesion and background and between the lesion and cerebrospinal fluid) for fast FLAIR exceeded the corresponding values for T2-weighted spin-echo images for all but the second-echo lesion-to-background C/N. Fast FLAIR provided equivalent or greater overall lesion conspicuity and enabled greater lesion detection in 98% and 100%, respectively, of the evaluations. Fast FLAIR images more often had image artifact, but this did not interfere with image interpretation in a significantly (P < or = .05) greater number of evaluations. CONCLUSION: Fast FLAIR provides images that are superior to proton-density- and T2-weighted images for many image quality criteria.


Assuntos
Artefatos , Encefalopatias/diagnóstico , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Fatores de Tempo
20.
Radiology ; 181(1): 33-9, 1991 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-1887053

RESUMO

Real-time interactive color flow magnetic resonance (MR) imaging is a combination of real-time MR imaging and color encoding of velocity-induced phase angle. Flow-compensated (FC) and flow-encoded (FE) images are acquired continuously by using gradient echoes and a 12-msec repetition time. Each image is reconstructed within 200 msec of acquisition, and the FC magnitude image is displayed in gray-scale format. The phase difference between the reconstructed FC and FE images, a difference proportional to velocity along the flow-encoding direction, is encoded in color and superimposed on the gray-scale FC image. Magnitude and phase information are thus presented simultaneously. The viewer may interactively adjust many acquisition parameters during data acquisition. Experimental results of phantom and in vivo human studies validate the method. Characteristics of the color flow MR imaging technique are compared with those of duplex color ultrasound.


Assuntos
Vasos Sanguíneos/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo , Humanos , Modelos Estruturais , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA