Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 380
Filtrar
1.
BMC Ophthalmol ; 24(1): 43, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38287315

RESUMO

BACKGROUND: Trachoma is a notifiable disease in the state of São Paulo- Brazil. However, in Jaú, a municipality located in this state, in the last 10 years there are no records of cases. This study purpose is to assess if there are cases of inflammatory trachoma in schoolchildren aged 1 to 9 years in the municipality of Jaú as well if it is possible to detect clusters areas of the disease to establish elimination programs. METHODS: An epidemiological study was performed in 2018, involving a stratified random sample of schoolchildren aged 1- to 9-year-old, from public day care centers and elementary schools in the municipality of Jaú. A trachoma screening following the criteria of the World Health Organization (WHO) and the distribution of cases was assessed using geoprocessing. RESULTS: Four thousand-six hundred-nineteen children from 44 elementary schools were examined, and 126 children with active trachoma were detected, with an adjusted prevalence rate of 2.65%. The prevalence was higher (3.01%) in children aged 6- to 9-year-old compared to children aged 1-to 5-year-old (2.42%). There were clusters with a higher concentration of positive cases of the disease in three schools located in the neighborhoods with lower socioeconomic conditions. CONCLUSION: Inflammatory trachoma still present in children aged 1- to 9-year-old in the city of Jaú. The positive cases were located mainly in areas with low socioeconomic conditions. Health promotion with active search and periodical treatment must be planned to fight this important blinding cause, that persists in our municipality.


Assuntos
Tracoma , Criança , Humanos , Lactente , Pré-Escolar , Tracoma/diagnóstico , Tracoma/epidemiologia , Brasil/epidemiologia , Estudos Epidemiológicos , Programas de Rastreamento , Projetos de Pesquisa , Prevalência
2.
Orbit ; : 1-6, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38100406

RESUMO

Primary sebaceous carcinoma of the lacrimal gland (PSCLG) is the rarest lacrimal gland (LG) tumor, often belatedly diagnosed, worsening the prognosis. We present a 68-year-old man with a large, indurated mass in the left orbital outer quadrant, visible at the conjunctival upper temporal fornix, extending to the lower fornix, with left gaze restriction. The lesion was not related to the eyelid or other periocular tissues. Excisional biopsy revealed the PSCLG diagnosis. There are only eight others previous PSCLGs. Males are the most affected. Indurated mass in the lacrimal fossa, with eyelid in "S" shape is the most common presentation. Image exams are suggestive, but histological and immunohistochemical evaluations showing a single tumor cell line within LG are mandatory for definitive diagnosis. Larger and more extensive lesions can have a poor prognosis, but early detection can favor the outcome.

3.
Orbit ; : 1-8, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38117477

RESUMO

A systematic literature review revealed 88 Rosai-Dorfman Disease (RDD) cases affecting the orbit. We present a review of the literature on orbital RDD in addition to two brothers with isolated bilateral extra-nodal orbital RDD cases associated with G-6PD deficiency. The disease manifested as asymmetric extensive orbital and paranasal sinus infiltration, with orbital bone destruction. Orbital mass debulking and steroids improved the condition in both patients. This is the most extensive case series of orbital RDD reported, including clinical manifestation, imaging, pathologic results, management, and outcome. Vigilant follow-up is essential to monitor for potential malignant transformation, systemic manifestations, potential vision loss, or life-threatening recurrences.

4.
Int Ophthalmol ; 43(11): 4297-4304, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37574470

RESUMO

PURPOSE: To analyse the ocularist's perspective on the management of the anophthalmic socket and external ocular prosthesis (EOP). METHODS: Ocularists from two countries were invited to participate in an online questionnaire. Data were collected on demographics, anophthalmic socket and EOP management (manufacturing, use, cleaning), complications, follow-up visits and multidisciplinary care. The frequency and proportions of the responses were statistically analysed. RESULTS: The questionnaire was addressed to 20 Brazilian and 17 Spanish ocularists, obtaining a response rate of 65% and 64.7%, respectively. 62.5% of respondents were men. The most common cause of anophthalmia in Brazil (69.2%) and Spain (36.4%) is an eye disease (chi square: p = 0.188). Polymethylmethacrylate (PMMA) is the most commonly used material in EOP manufacture (chi square: p = 0.448), and 70.8% reported using customized EOPs (chi square: p = 0.069). Deposits are frequently observed in both countries (chi square: p = 0.157). Changing the prosthesis is recommended after 5 to 10 years by Brazilian ocularists, and after less than 5 years of use by Spanish ocularists (81.8%) (chi square: p = 0.041). Annual follow-up is recommended by Spanish ocularists (45.5%), while semestral (38.5%) and case-dependent (38.5%) follow-up is recommended by Brazilian ocularists (chi square: p = 0.267). Daily cleaning is advocated by 61.5% of Brazilian ocularists and once a month by 45.5% of Spanish ocularists (chi square: p = 0.098), with 75% of ocularists from both countries not recommending EOP removal at night (Fisher´s exact test: p = 0.166). Good communication between ocularists and ophthalmologists was reported by 87.5% of our responders (chi square: p = 0.642). CONCLUSION: Although there are no unified protocols on the management of EOPs, Brazilian and Spanish ocularists follow similar guidelines. Differences between countries were the patients´ referral and the prosthesis´ useful life.


Assuntos
Anoftalmia , Olho Artificial , Masculino , Humanos , Feminino , Brasil , Espanha , Implantação de Prótese/métodos , Inquéritos e Questionários , Anoftalmia/cirurgia
5.
Orbit ; 41(6): 700-707, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34958290

RESUMO

PURPOSE: To evaluate lower lid position and tear meniscus in peripheral idiopathic facial nerve palsy (FNP). METHODS: A prospective study enrolled patients with peripheral idiopathic FNP and epiphora. Data were collected on patient demographics, House-Brackmann (HB) scale, digital photographs of the face, and tear meniscus at the 1st, 30, and 90 day after onset of FNP. Marginal reflex distance to the upper (MRD1) and lower eyelid (MRD2) were evaluated using ImageJ software. Anterior segment optical coherence tomography (OCT) was performed to measure the tear menis- cus. P< .05 was considered statistically significant. RESULTS: Sixteen patients were evaluated. The HB scale at presentation was grade III in six patients (37.5%). At 90 day, nine patients (56.25%) were grade I-normal. Three (18.7%) had upper lid retraction, three (18.7%) upper eyelid asymmetry and 7 (43.75%), lower eyelid retraction. The difference between MRD2-FNP with MRD2-healthy side was 0.51 ± 1.9 mm at the 1st visit, decreasing to 0.09 ± 1.47 mm at 90 days (P= .877). Tear meniscus measurements were significantly higher in FNP at the 1st visit (P= .001). The decrease in MRD2 was statistically correlated with the reduction of the tear meniscus area (TMA) (r = 0.67; P= .007) at 90 days. No correlation was found between HB and TMA. There is a difference in TMA between age groups at the 1st day(p= .009). Eldest group had higher HB scales. CONCLUSION: Quantitative evaluation of eyelid position and tear meniscus are effective to document the evolution of FNP and can serve as a clue of orbicularis recovery.


Assuntos
Doenças Palpebrais , Paralisia Facial , Menisco , Humanos , Estudos Prospectivos , Nervo Facial , Pálpebras , Lágrimas/fisiologia , Paralisia Facial/diagnóstico , Tomografia de Coerência Óptica
6.
Orbit ; 41(6): 708-716, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34842036

RESUMO

PURPOSE: To evaluate the amplitude of movement in anophthalmic sockets reconstructed with conical or spherical orbital implants with and without an external ocular prosthesis (EOP), and whether the fornix depth could play a role. METHODS: Prospective observational study involving unilateral anophthalmic sockets evaluated the amplitude of movement with conical (20 subjects) or spherical (16) non-porous orbital implants, with and without an EOP, having the contralateral eye as the control group. Standardized photographs were obtained in the four gaze directions and measurements were performed using the Image J software. The upper and lower fornix depths were measured using rulers. RESULTS: Compared to the contralateral eye, the median movement amplitude without EOP was smaller with conical implants in supraduction (-0.88 mm, p=0.008), abduction (-2.26 mm, p<0.001) and adduction (-0.91 mm, p=0.008). Spherical implants had reduced movement only in abduction (-2.63 mm, p<0.001). Conical and spherical implants had similar amplitudes of movement in all versions, and were always smaller compared to the control. The median movement amplitude with the EOP was -3.05 mm (p=0.001) than without the EOP in abduction and -2.07 mm (p=0.020) in adduction, regardless of implant format. The fornix depth did not affect the orbital implants or EOP movement amplitude's median. CONCLUSION: Conical and spherical implants provide similar amplitude of movement and fornix depth did not have an influence on it. The amplitude of movement was significantly limited compared to the contralateral eye and was even more reduced if the EOP was in place with conical or spherical implant formats.


Assuntos
Anoftalmia , Implantes Orbitários , Humanos , Enucleação Ocular , Anoftalmia/cirurgia , Olho Artificial , Estudos Prospectivos , Órbita/cirurgia
7.
Orbit ; 41(6): 691-699, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34708673

RESUMO

PURPOSE: To evaluate the outcomes of orbital hydrogel expanders in the management of congenital anophthalmia. METHODS: In this retrospective one-armed cohort study, a chart review was performed of eight children with congenital anophthalmia who underwent orbital expansion using orbital hydrogel tissue expander from January 2006 to July 2018. Computed tomography (CT) of orbital parameters was evaluated before and after surgery. Changes in the orbital parameters were correlated with clinical factors. RESULTS: The study sample comprised 11 anophthalmic orbits of eight children (seven males, one female; median age = 12 months), with a median postoperative follow-up of 3.8 years. The anophthalmic orbital parameters after hydrogel expander implantation improved significantly compared to preoperative assessment as follows: mean orbital height improved from 21.7 mm to 25.4 mm (P < .001); width from 19.2 mm to 23.8 mm (P < .001); depth from 27.5 mm to 32.6 mm (P = .008); and volume from 3.7 cm3 to 5.3 cm3 (P = .001). Despite enlargement in all dimensions, the anophthalmic orbits with hydrogel expander had a significantly lower development than the normal orbits, mainly in height and volume. At the last postoperative visit, four (36.4%) cases had fornices deep enough to maintain the conformer. Migration and extrusion occurred in two (18.2%) cases. CONCLUSIONS: Orbital hydrogel expander can improve the orbital development in congenital anophthalmia. However, the enlargement is not as extensive as that observed in the normal orbit. Orbital expanders associated with external conformers were not sufficient to induce normal growth of lids and fornix.


Assuntos
Anoftalmia , Criança , Masculino , Feminino , Humanos , Lactente , Anoftalmia/diagnóstico por imagem , Anoftalmia/cirurgia , Dispositivos para Expansão de Tecidos , Hidrogéis/uso terapêutico , Estudos Retrospectivos , Estudos de Coortes , Órbita/cirurgia , Tomografia Computadorizada por Raios X
8.
Eye Contact Lens ; 47(7): 383-387, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34128481

RESUMO

OBJECTIVE: To report the outcomes and complications of colored soft contact lenses (SCLs) to improve esthetic or eye function in visually impaired (VI) or blind patients. METHODS: This retrospective study enrolled consecutive patients with unilateral or bilateral VI or blindness who had received colored SCLs to improve appearance or ocular function. Data were collected on demographics, complaints, complete ophthalmological examinations, types of SCL, follow-ups, and complications. RESULTS: The study sample was comprised of 109 patients (ages 4-80 years). Eighty-six patients (78.89%) had unilateral blindness, and 14 patients (12.84%) had functional disorder. Most of the patients presenting for improved esthetic had anterior segment pathology (74/67.88%), mainly secondary to trauma (55/50.5%) resulting in leukoma (73/66.97%). Patients with functional VI (19/17.43%) received filtered SCLs for color blindness (7/6.42%), diplopia (7/6.42%), or photophobia (5/4.58%). No serious complications were observed in any cases, and 94.49% of patients were satisfied with the SCLs. CONCLUSION: Colored SCLs can cover ocular surface imperfections in VI or blind eyes of patients who are seeking better cosmesis or improvement functional VI. Soft contact lenses with only one filter can cover imperfections of the ocular surface and improve vision in functional VI. Appropriate follow-up of these patients can reduce complication rates, resulting in good cosmesis and patient satisfaction with a positive impact on the lives of patients suffering from functional VI or blindness.


Assuntos
Lentes de Contato Hidrofílicas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cegueira , Criança , Pré-Escolar , Estética , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Visão Ocular , Adulto Jovem
9.
Ophthalmic Plast Reconstr Surg ; 36(2): e51-e53, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31868790

RESUMO

Focal eosinophilic myositis (FEM) is a rare disease that is even more uncommon in affecting the periocular area. The authors are reporting the first case of FEM occurring in the lower eyelid of a 45-year-old Caucasian female who presented with localized painful area of glossy induration and peau d'orange skin lesion. Magnetic resonance image shows significant hyperintense thickening of the pre-septal orbicularis muscle region on T2-weighted images. Incisional biopsy of the induration revealed marked fibrinoid degeneration of the orbicularis muscle and adjacent fascia, mixed cellular infiltration of lymphocytes and eosinophils and a predominant CD8+ lymphocytic infiltrates in the immunohistochemical study. The final diagnosis was FEM. Oral prednisolone improved symptoms and the lesions disappeared, with no recrudescence in a one year follow-up.


Assuntos
Distrofia Muscular do Cíngulo dos Membros , Miosite , Biópsia , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Músculos
10.
J Craniofac Surg ; 31(6): 1838-1840, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32796301

RESUMO

The ideal implant for anophthalmic socket reconstruction has yet to be developed. Biosilicate, a highly bioactive glass-ceramic, has been used in the composition of conical implants, which were initially tested in rabbit orbits with excellent results. However, the use of this material and the conical shape of the implants require further study in the human anophthalmic socket. Thus, we propose the use of a new conical implant composed of Biosilicate for orbital volume augmentation in anophthalmic sockets. This prospective, randomized study included 45 patients receiving conical implants composed of either Biosilicate or polymethylmethacrylate (control). Patients were evaluated clinically before and 7, 30, 60, 120, and 180 days after implantation. Systemic evaluations, laboratory tests, and computed tomography of the orbits were performed preoperatively and 180 days postoperatively. Both groups had good outcomes with no significant infectious or inflammatory processes. Only 1 patient, in the Biosilicate group, had early implant extrusion. Laboratory tests were normal in both groups. Computed tomography scans showed that the implants in both groups were well positioned. The new conical implant composed of Biosilicate was successfully used for anophthalmic socket reconstruction. This implant may provide a good alternative to the only conical implant currently available on the market, which is composed of porous polyethylene.


Assuntos
Anoftalmia/cirurgia , Vidro , Doenças Orbitárias/cirurgia , Implantes Orbitários , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Implantação de Prótese/métodos , Adulto Jovem
11.
Orbit ; 39(4): 258-265, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31662017

RESUMO

PURPOSE: To evaluate the effect of stents on the success of endoscopic dacryocystorhinostomy (DCR-EN) for treating primary acquired nasolacrimal duct obstruction (NLDO). METHOD: A systematic review of randomized clinical trials of DCR-EN for NLDO comparing outcomes of surgeries performed with and without the use of bicanalicular stents and the complications associated with each procedure. Two authors independently searched six databases (Scopus, PubMed, EMBASE, Google Scholar, Cochrane Central Register of Controlled Trials, and Web of Science) up to May 2019. Statistical analysis and meta-analysis were performed using RevMan 5.3 software provided by the Cochrane Collaboration. RESULTS: Twelve studies involving 997 surgeries were included in this systematic review. The meta-analysis using a fixed-effects model showed a 94% success rate with stents versus 90.6% without stent. Although stent use favors greater success of DCR-EN, the confidence interval (CI) was wide and very close to nullity line (1.01), decreasing the strength of the recommendation for stent (odds ratio: 1.62, 95% CI: 1.01-2.59, I 2 = 0%). Meta-analysis of the adverse effects was not possible. A descriptive analysis was performed of the general complications related to the stents. CONCLUSIONS: There is evidence that the use of bicanalicular stents slightly improves the success rate of DCR-EN, but the quality of evidence is low. Future prospective, randomized trials enrolling larger sample sizes may provide stronger evidence to determine whether the stent use influences the success of primary acquired DCR-EN.


Assuntos
Dacriocistorinostomia/métodos , Endoscopia/métodos , Obstrução dos Ductos Lacrimais/terapia , Ducto Nasolacrimal/cirurgia , Stents , Humanos , Intubação/métodos , Resultado do Tratamento
12.
Orbit ; 39(6): 441-445, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31914837

RESUMO

The authors are describing two rare cases of dacryops involving the Krause accessory lacrimal glands and affecting the orbit. In both cases, the lesion was located in the inferior fornix, with no preceding trauma, surgery or trachomatous conjunctival scarring. The first case involved a clear orbital extension with evidence of optic nerve compression. The second case extended from the anterior orbit to the limbus. Both had surgical removal with good outcome. As Krause gland dacryops are similar to other orbital cysts, clinical, imaging and histopathologic evaluation are essential to confirm the final diagnosis.


Assuntos
Cistos/patologia , Doenças do Aparelho Lacrimal/patologia , Adolescente , Adulto , Biópsia , Cistos/diagnóstico por imagem , Cistos/cirurgia , Feminino , Humanos , Doenças do Aparelho Lacrimal/diagnóstico por imagem , Doenças do Aparelho Lacrimal/cirurgia , Imageamento por Ressonância Magnética , Masculino , Procedimentos Cirúrgicos Oftalmológicos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
13.
Orbit ; 39(5): 325-330, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31722593

RESUMO

PURPOSE: To study the clinical features, histopathology, and management of congenital upper eyelid coloboma (CEC) in the Saudi population. METHODS: A retrospective review of health records evaluated the demographics, histopathology, and surgical outcomes of patients with CEC. RESULTS: Thirty-nine eyelids of 27 patients were included in this study. CEC was bilateral in 12 (44.4%) patients, isolated in 17 (62.9%), and as part of a syndrome in 10 (37.1%) patients. CEC was commonly located in the medial upper lid (22 lids, 56.4%) and mostly involved the full thickness of the lid (27 lids, 69.2%). Corneal adhesion (18 eyes, 46.1%) and poorly formed eyebrows (21 eyebrows, 53.8%) were the most common ocular/adnexa associations. Histopathology was similar in all cases and the main features were scarred dermis, atrophic orbicularis oculi, and atrophic or absent tarsus. Visual acuity at the final follow-up was 20/50 or better in 13 (33.3%) eyes. Complete lid closure without lagophthalmos after one or more surgical procedures was achieved in 11 (40.7%) cases. CONCLUSIONS: CEC features in Saudi patients are similar to those described in the literature. Dermal scarring and defective orbicularis muscles are common. Achieving cosmetic and functional success after management remains challenging.


Assuntos
Coloboma/patologia , Pálpebras/anormalidades , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Coloboma/epidemiologia , Coloboma/cirurgia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Oftalmológicos , Estudos Retrospectivos , Arábia Saudita/epidemiologia , Acuidade Visual
14.
Graefes Arch Clin Exp Ophthalmol ; 257(7): 1353-1364, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30895451

RESUMO

PURPOSE: To provide a focused review of sickle cell retinopathy in the light of recent advances in the pathogenesis, multimodal retinal imaging, management of the condition, and migration trends, which may lead to increased prevalence of the condition in the Western world. METHODS: Non-systematic focused literature review. RESULTS: Sickle retinopathy results from aggregation of abnormal hemoglobin in the red blood cells in the retinal microcirculation, leading to reduced deformability of the red blood cells, stagnant blood flow in the retinal precapillary arterioles, thrombosis, and ischemia. This may be precipitated by hypoxia, acidosis, and hyperosmolarity. Sickle retinopathy may result in sight threatening complications, such as paracentral middle maculopathy or sequelae of proliferative retinopathy, such as vitreous hemorrhage and retinal detachment. New imaging modalities, such as wide-field imaging and optical coherence tomography angiography, have revealed the microstructural features of sickle retinopathy, enabling earlier diagnosis. The vascular growth factor ANGPTL-4 has recently been identified as a potential mediator of progression to proliferative retinopathy and may represent a possible therapeutic target. Laser therapy should be considered for proliferative retinopathy in order to prevent visual loss; however, the evidence is not very strong. With recent development of wide-field imaging, targeted laser to ischemic retina may prove to be beneficial. Exact control of intraoperative intraocular pressure, including valved trocar vitrectomy systems, may improve the outcomes of vitreoretinal surgery for complications, such as vitreous hemorrhage and retinal detachment. Stem cell transplantation and gene therapy are potentially curative treatments, which may prevent retinopathy. CONCLUSIONS: There is lack of evidence regarding the optimal management of sickle retinopathy. Further study is needed to determine if recent progress in the understanding of the pathophysiology and diagnosis of sickle retinopathy may translate into improved management and outcome.


Assuntos
Angiofluoresceinografia/métodos , Hemoglobinas/metabolismo , Fotocoagulação a Laser/métodos , Retina/diagnóstico por imagem , Doenças Retinianas , Tomografia de Coerência Óptica/métodos , Anemia Falciforme/complicações , Anemia Falciforme/diagnóstico , Anemia Falciforme/epidemiologia , Fundo de Olho , Saúde Global , Humanos , Prevalência , Doenças Retinianas/diagnóstico , Doenças Retinianas/etiologia , Doenças Retinianas/cirurgia
15.
J Craniofac Surg ; 30(4): 1184-1186, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31166263

RESUMO

PURPOSE: To evaluate the characteristics of bilateral nasolacrimal duct obstruction (NLDO) carriers and success rates of same day (simultaneous) or asynchronous (different day) bilateral dacryocystorhinostomy (DCR). METHODS: This retrospective study included patients with bilateral NLDO who underwent bilateral external DCR between January 2010 to August 2015 at the King Khaled Eye Specialist Hospital, Saudi Arabia. Postoperative success rate was considered as subjective perception of no tearing bilaterally or failure if unilateral or bilateral tearing persists after surgery. Data were statistically analyzed with P <0.05 indicating significance. RESULTS: Of 57 patients undergoing bilateral DCR, 32 (56%) had same-day surgeries and 25 underwent asynchronous surgery. The median duration of follow up was 7 months. The success rates were similar for the same day group [61.3%-95% CI 49.4-73.2)] and for the asynchronous group [54.2% (95% CI 40.4-68.0)]. Success rate was not correlated to the age, gender, or use of stents. CONCLUSIONS: The authors strongly recommend bilateral same-day external DCR to treat bilateral NLDO since the success rate of the procedure is similar to the asynchronous surgery, allowing a full treatment in just 1 operative visit.


Assuntos
Dacriocistorinostomia/métodos , Obstrução dos Ductos Lacrimais , Adulto , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
16.
Orbit ; 38(3): 192-198, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30285524

RESUMO

Purpose: The purpose of the study is to evaluate demographic data and outcomes of the management of congenital anophthalmia/microphthalmia. Methods: This retrospective, descriptive, cross-sectional study evaluated patients with congenital anophthalmia/microphthalmia managed from 2004 to 2014 at a tertiary hospital in Saudi Arabia. Data were collected on patient age, gender, cause, orbital status, laterality, systemic comorbidities, ocular evaluation, and management (type of surgery, type of orbital implant, and complications). The main outcome measure was the ability to hold the prosthesis. Results: The study sample was composed of 513 eyes/sockets of 365 patients. Two-hundred and seventeen (59.4%) patients were unilateral cases. Forty-one (8%) sockets were due to congenital anophthalmia and 471 (92%) were due to microphthalmia. There were 73.2% isolated cases and 28.5% with systemic involvement. Systemic involvement was more common in bilateral cases. The most commonly associated conditions were central nervous disorders. One-hundred and nineteen (46.7%) cases had parental consanguinity. Two hundred and eighteen eyes/sockets (163 patients) underwent surgery including conjunctival flap (38; 17.4%), evisceration (38; 17.4%), enucleation (16; 7.3%), or procedures to improve the anophthalmic socket volume (45; 20.6%). Volume enhancing procedures included polymethylmethacrylate orbital implants (26; 57.8%), expanders (11; 24.4%), integrated hydroxyapatite or polyethylene implants (2; 4.4%), and dermis-fat graft (6; 13.3%). In most cases, clinical or surgical management resulted in a successful outcome. Conclusion: Anophthalmia/Microphthalmia was detected in 36.5 patients/year. The majority had isolated microphthalmia. Good outcomes were achieved with clinical or surgical management in the majority of cases.


Assuntos
Anoftalmia/cirurgia , Olho Artificial , Microftalmia/cirurgia , Implantes Orbitários , Implantação de Prótese/métodos , Adolescente , Anoftalmia/diagnóstico por imagem , Estudos Transversais , Enucleação Ocular , Evisceração do Olho , Feminino , Humanos , Masculino , Microftalmia/diagnóstico por imagem , Estudos Retrospectivos , Retalhos Cirúrgicos , Centros de Atenção Terciária , Tomografia Computadorizada por Raios X , Acuidade Visual/fisiologia
17.
Ophthalmic Plast Reconstr Surg ; 34(2): 136-139, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28296654

RESUMO

PURPOSE: To evaluate the suitability of Nanoskin, a biomaterial derived from bacterial cellulose, as an alternate material for repairing the posterior lamellae of the eyelids. METHODS: Forty guinea pigs received a fragment of Nanoskin subcutaneously in the dorsal region. The animals received Nanoskin (group 1) or Nanoskin coated with a gelatin layer (group 2). The animals were observed daily for over 7, 30, 90, or 180 days with the subcutaneous implants in place. The animals were euthanized at a designated time and the Nanoskin was removed for histologic, morphometric, and transmission electron microscopy evaluation. RESULTS: The results were similar for both groups. The subcutaneously implanted Nanoskin resulted in good tissue integration, induced mild inflammation, and was surrounded by a delicate pseudocapsule. CONCLUSION: The good tissue integration of Nanoskin in study indicates that it may be a potential material for application as a substitute of posterior eyelid lamellar tissue. Further clinical studies are required to confirm the preliminary outcomes of this experimental study.


Assuntos
Materiais Biocompatíveis/uso terapêutico , Celulose/uso terapêutico , Pálpebras/cirurgia , Nanoestruturas , Próteses e Implantes , Animais , Modelos Animais de Doenças , Cobaias , Próteses e Implantes/ultraestrutura
18.
J Craniofac Surg ; 29(6): 1607-1611, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29742574

RESUMO

PURPOSE: The aim of thhis study was to present the outcomes of postauricular split-medium thickness skin graft (SMTSG) to treat anophthalmic sockets with contracted fornices. METHODS: This case series enrolled patients with grade 2 or 3 anophthalmic sockets between 2015 and 2016. Data were collected on patient demographics, objective and subjective parameters preoperatively and 180 days postoperatively. Success of the surgery was graded on the height of the graft, the depth of the superior and inferior fornices, and presence/abscence of lagophthalmos, entropion, and ability to retain an external prosthesis. RESULTS: Eighteen patients were enrolled with a mean age of 35.9 ±â€Š18 years. The median height of the graft was 22 mm (25% quartile = 18.75) when removed and 20 mm (25% quartile = 16) postoperatively. The median depth of the superior fornix was 6.5 mm (25% quartile = 4.5 mm) preoperatively and 10 mm (25% quartile = 8 mm) postoperatively (P = 0.5). The median inferior fornix depth was 7 mm (25% quartile = 3.5 mm) preoperatively and 8 mm (25% quartile = 5 mm) (P = 0.27) postoperatively. Preoperatively, there were 13 (72.2%) patients with lagophthalmos, 10 (44.4%) with entropion, 3 (37.5%) with poor prosthesis retention, and 5 (62.5%) who were unable to retain the prosthesis. Postoperatively, 7 (38.9%) patients had lagophthamos, 1 (5.6%) had entropion, and all the patients could retain the prosthesis. None of the sockets had a foul odor postoperatively. CONCLUSIONS: Postauricular SMTSG achieves successful outcomes for the treatment of contracted anophthalmic sockets, reshaping the anterior socket surface and deepening the fornices.


Assuntos
Anoftalmia/complicações , Túnica Conjuntiva/cirurgia , Órbita/cirurgia , Transplante de Pele/métodos , Adolescente , Adulto , Túnica Conjuntiva/patologia , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Entrópio/etiologia , Olho Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Órbita/patologia , Período Pós-Operatório , Adulto Jovem
19.
J Craniofac Surg ; 29(8): e777-e779, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30028403

RESUMO

This case series present the surgical management of cases with severe contracted sockets using a split-skin-graft wrapped conformer. Eight patients with severely contracted anophthalmic sockets underwent surgery. The surgical technique is described and a chart review was performed to collect patient data pre- and postoperatively. Preoperatively, all patients had grade 3 or 4 contracted sockets with shallow or obliterated fornices and patients were unable to retain an external prosthesis in place. Donor material was harvested from the supraclavicular area. The split-skin-graft was successfully performed in all cases without fornix-deepening sutures. All patients underwent a significant improvement of socket contracture enabling retention of the prosthesis and were satisfied with the outcomes. The split-skin-graft wrapped conformer is a rapid and less surgically challenging option to correct severe contracted anophthalmic sockets.


Assuntos
Anoftalmia/complicações , Implantação de Prótese/métodos , Transplante de Pele/métodos , Adulto , Idoso de 80 Anos ou mais , Criança , Contratura/etiologia , Contratura/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Próteses e Implantes , Adulto Jovem
20.
Orbit ; 37(2): 87-90, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29058522

RESUMO

PURPOSE: To describe a new technique to treat congenital distichiasis. METHODS: Case series of three distichiatic patients undergoing a novel surgical technique combining splitting of the lid margin with the distichiatic lashes, marginal tarsectomy in the affected area, and tarsoconjunctival graft obtained from the upper region of the tarsus. The graft was sutured at the exposed region of the marginal tarsectomy. RESULTS: Good cosmesis was obtained in all cases and the lids margins healed completely with good surgical outcome and no lashes contacted the cornea postoperatively. CONCLUSIONS: The split lamellae with a composite tarsoconjunctival graft results in satisfactory functional and cosmetic outcomes. The upper tarsal region represents an ideal donor site.


Assuntos
Anormalidades do Olho/cirurgia , Pestanas/anormalidades , Doenças Palpebrais/cirurgia , Doenças do Cabelo/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Criança , Pré-Escolar , Doenças Palpebrais/congênito , Feminino , Doenças do Cabelo/congênito , Humanos , Masculino , Técnicas de Sutura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA