Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Filtros aplicados
Base de dados
Intervalo de ano de publicação
1.
Allergol. immunopatol ; 51(3): 111-116, 01 mayo 2023. ilus
Artigo em Inglês | IBECS | ID: ibc-219818

RESUMO

Allergic rhinitis (AR) is a common atopic problem in which immune response to the environmental factors leads to clinical symptoms. Helicobacter pylori neutrophil-activating protein (HP-NAP) as a peptide attenuates Th2 response and stimulates Th1 activation and mucus adhesion promoting protein (MapA) as a cell-surface protein binds to mucus. This study evaluated the effect of HP-NAP and MapA conjugated with alumina nanoparticle on AR. HP-NAP and HP-NAP with MapA were conjugated to alumina nanoparticle and two separate nanoparticles were produced. The AR mice were treated with these and HP-NAP in peptide form. The AR symptoms, gene expression of mucus, levels of IL-33 and IL-4, and total and ovalbumin (OVA)-specific IgE levels were evaluated. Nasal rubbing, sneezing, gene expression of mucus, and IL-33 and IL-4 levels, and OVA-specific and total IgE were decreased in three treated groups compared to AR, and there was a significant decrease in the symptoms in AR-H-M-A group (P < 0.05) when compared to the other treated groups. HP-NAP has a controlling effect on AR, and in nanoparticle-conjugated form it can strongly attach to the airway’s mucus via MapA. Therefore, cooperation of HP-NAP-alumina with MapA can produce an effective and applicable treatment for AR (AU)


Assuntos
Animais , Masculino , Camundongos , Rinite Alérgica/tratamento farmacológico , Nanopartículas , Óxido de Alumínio/uso terapêutico , Anti-Inflamatórios/uso terapêutico , Modelos Animais de Doenças , Camundongos Endogâmicos BALB C
2.
Med. oral patol. oral cir. bucal (Internet) ; 15(1): 95-100, ene. 2010. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-78778

RESUMO

To evaluate bond strengths of different resin cements to two aluminum oxide-based ceramics. Methods: Onehundred ten ceramic cylinders were produced and given four different surface treatments. Resin cement cylinderswere then bonded to the ceramic cylinders using different resin cements and the bond strength was determinedby shear testing to the breaking point. We were thus able to obtain results for the different combinations of porcelain,surface treatments and cements. All data was analyzed using the Kruskal-Wallis test for more than twoindependent samples and the Bonferroni correction applied (a=0.01). An optical microscopy study was carriedout to analyze the type of failure, and an electronic microscopy examination was carried out in order to evaluatethe changes produced in the ceramic by the different surface treatments. Results: The best values correspondedto the control group, composed of silicate ceramics combined with Variolink II resin cement. In-Ceram Aluminashowed no significant differences with respect to the type of cement applied. Procera AllCeram obtained the bestvalues when silica coated using the CoJet System and applying Variolink II, or when sandblasted and applyingClearfil SE Bond + Porcelain Bond Activator and Panavia F cement. Significance: Surface treatment modifies theceramic surface and influences the bond strength, as does the type of cement used. Silica coating is recommendedto improve adhesion to Procera AllCeram, applying Variolink II, or sandblasting plus resin cement containingMDP (Panavia F) (AU)


No disponible


Assuntos
Colagem Dentária , Teste de Materiais , Cimentos de Resina , Óxido de Alumínio , Cerâmica
3.
Rev. esp. cir. oral maxilofac ; 29(4): 260-269, jul.-ago. 2007. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-74640

RESUMO

La reabsorción ósea de los maxilares ha sido una de las mayorescomplicaciones al momento de rehabilitar a pacientes con implantes oseointegrados. El siguiente estudio evaluó la efectividad de la membrana de óxido de aluminio (alúmina), en la regeneración ósea de rebordes colapsados y alvéolos en los que se colocaron implantes. De un total de cinco pacientes seleccionados, se estudiaron siete sitios de los cuales tres correspondieron a un solo paciente. En cada sitio (alvéolo o reborde colapsado) se colocó un implante de titanio del sistema HIS y una membrana no biodegradable de óxido de aluminio (Allumina(R)), la cual fue retirada a las 14semanas. Todos los pacientes fueron sometidos al mismo procedimiento quirúrgico. La ganancia promedio en mm obtenidos en orden decreciente fue la siguiente: ANM: 1.7 mm, ANME: 1.6 mm, AND: 1.1 mm, AV: 1.0mm, AP: 0.5mm. Los resultados radiográficos ratificaron los resultados clínicosen cuanto a neoformación ósea, observándose además una favorable densidad ó se a periimplantaria. El análisis estadístico (basado en los resultados clínicos) t-student fue significativo para todos los parámetros evaluadoscon excepción de AP (AU)


Alveolar bone loss has been a very important cause ofcomplications in osseointegrated implant rehabilitation of edentulouspatients. This paper evaluates the effectiveness of aluminum oxidemembrane (Allumina) in the collapsed alveolar ridge where implantswere used. Seven sites were studied in 5 patients. In each of thesesites a HIS implant plus a non-biodegradable oxide aluminummembrane (Allumina®), was placed for 14 weeks. All patients weretreated with the same surgical protocol. The average gain (in mm)obtained in decreasing order was as follows: ANM: 1.7 mm, ANME:1.6 mm, AND: 1.1mm, AV: 1.0mm, AP: 0.5mm. The clinical resultswere radiographically verified and these showed bone neoformation,in addition to favorable peri-implant bone density. The t-Studentstatistical analysis based on the clinical results was significant forall the parameters evaluated with the exception of AP (AU)


Assuntos
Humanos , Regeneração Tecidual Guiada/métodos , Óxido de Alumínio/uso terapêutico , Implantação Dentária Endóssea/métodos , Membranas Artificiais , Osteogênese , Reabsorção Óssea/terapia
4.
Ars pharm ; 47(4): 425-435, 2006. ilus, tab
Artigo em Es | IBECS | ID: ibc-054053

RESUMO

Con la intención de preparar suplementos dietéticos de bajo coste, se inmovilizó papaína en carbón activado (CA) y en alúmina, utilizando suero como fuente de proteínas hidrolizadas. Para determinar el índice de inmovilización se cuantifi caron las enzimas no adsorbidas mediante el método de Lowry. Se analizó el efecto del tiempo de contacto y la temperatura, considerándose 30 min. a 25 ºC como la condición óptima para inmovilizar la papaína en ambos soportes. El CA presentó unos índices de inmovilización muy superiores (entre 95% y 99%) a los de la AL (entre 4% y 13%). Para evaluar la capacidad de reutilización de la papaína se midió la actividad residual de la enzima después de haber sido utilizada hasta 20 veces. Para determinar la actividad de la enzima se cuantifi có el índice de exposición de la fenilalanina mediante espectrofotometría de derivada segunda. En este caso, la AL presentó mejores resultados que el CA, ya que la actividad de la papaína seguía siendo la misma después de haber sido utilizada 15 y 5 veces, respectivamente


Papain was immobilized on activated carbon (AC) and on alumina (AL), with the aim of preparing low cost dietary supplements, using whey as hydrolysed protein source. The quantifi cation of the non-adsorbed enzyme, using Lowry’s method was used to determine the immobilization rate. The effect of the contact time and the temperature was tested, and 30 min at 250C was considered the best condition for immobilizing papain in both supports. AC showed much higher immobilization rates (from 95% to 99%) than AL (from 4% to 13%). The reusability of papain was evaluated by measuring the residual activity of the enzyme after it has been used for up to 20 times. The quantifi cation of exposure rate of phenylalanine by second derivative spectrophotometry was used to determine the enzyme activity. In this case, AL showed better results than AC, since the activity of papain remained unchanged after 15 and 5 times, respectively


Assuntos
Humanos , Papaína/química , Suplementos Nutricionais/análise , Espectrofotometria/métodos , Estabilidade de Medicamentos , Óxido de Alumínio/análise , Óxido de Alumínio/química
5.
Ortod. esp. (Ed. impr.) ; 44(2): 101-107, abr. 2004. ilus, tab
Artigo em Es | IBECS | ID: ibc-32153

RESUMO

Se prepararon 450 muestras de amalgama de plata, sobre las cuales se efectuó un pulido de la superficie, un rayado con una fresa de diamante o un microarenado con óxido de aluminio. Se cementaron brackets metálicos con diferentes adhesivos: System 1+, Concise, Concise sistema ortodóncico, Panavia 21 EX y All Bond . Se realizó la tracción de las muestras y los valores de fuerzas más elevados se observaron en las muestras rayadas o microarenadas, sin encontrarse diferencias significativas entre ambos grupos, mientras que sí había diferencia significativa con aquellas en las que se realizó el pulido de la amalgama. Entre las resinas utilizadas el Panavia mostró los valores más altos de fuerza de rotura (8,70 Mpa) (AU)


Assuntos
Adolescente , Adulto , Feminino , Masculino , Criança , Humanos , Resistência à Tração/fisiologia , Aparelhos de Tração Extrabucal , Cimentos de Resina/análise , Cimentos de Resina/uso terapêutico , Resinas/uso terapêutico , Resinas Acrílicas/uso terapêutico , Amálgama Dentário/análise , Amálgama Dentário/uso terapêutico , Óxido de Alumínio/uso terapêutico , Cemento Dentário , Análise de Variância , Ortodontia/classificação , Ortodontia/tendências , Ortodontia/instrumentação
6.
Rev. ortop. traumatol. (Madr., Ed. impr.) ; 47(6): 434-442, nov. 2003. ilus, tab, graf
Artigo em Es | IBECS | ID: ibc-28878

RESUMO

La búsqueda de la longevidad de los implantes protésicos articulares es uno de los imperativos que más preocupan hoy día a los investigadores y a los cirujanos ortopédicos que trabajan en este campo. Efectivamente, cada día se afrontan pacientes de menor edad deseosos de seguir una actividad vital normal, incluso de participar regularmente en deportes con impactos o en tareas pesadas y de carga. En el caso de las artroplastias de cadera se ha conseguido un buen funcionamiento de las mismas, casi asegurado en los primeros 10 años tras su implantación; sin embargo, a partir de ese plazo la supervivencia decrece. El fracaso del implante suele sobrevenir por desgaste de sus componentes articulares o por pérdida de fijación al hueso huésped, estando ambas causas íntimamente relacionadas. En este artículo se revisan los materiales utilizados en superficies articulares y después se analizan los que entran a formar parte de la composición estructura del sustrato y de las superficies de fijación de la prótesis (AU)


Assuntos
Humanos , Artroplastia de Quadril/instrumentação , Materiais Biocompatíveis/análise , Polietilenos/análise , Óxido de Alumínio/análise , Revestimento de Dentadura , Cimentos Ósseos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA