Resumo
The objective of this study was to establish ophthalmic parameters in the Pomeranian dog breed. Schirmer tear test (STT), tear breakup time test (TBUTT), Jones test (JT), aesthesiometry, biomicroscopy, tonometry, non-contact specular microscopy (SM), ophthalmoscopy and ultrasonography (US) were carried out 48 eyes of 24 male and female Pomeranian dogs from a breeding kennel. Descriptive statistics was applied for data analysis. Means and standard errors found for STT, TBUT, JT, esthesiometry and tonometry were 24.310±0.448mm/min, 14.570±0.406s., 8.420±1.571min, 3.667±0.157cm and 17.960±0.697mmHg, respectively. For biomicroscopy, 43.75% of the eyes presented caruncle trichiasis, 25% chromodacryorrhea, 25% medial entropion and 10,42% distichiasis. SM showed endothelial cells density of 1958.285±36.760 cells/mm². For hexagonality, endothelial cells area and central corneal thickness were 62.229±2.183%, 519.231±9.853mm², 0.567±0.006mm, respectively. Ophthalmoscopy presented a pattern described in other breeds. Amelanotic fundus was reported in 8.33% of the eyes. The US means and standard errors for axial length of the eyeball, lens thickness, anterior and vitreous chamber depth were 16.859±0.148mm, 6.651±0.081mm, 2.673±0.091mm and 7.485±0.101mm. Mild changes in the lacrimal evaluation parameters were influenced by eyelid changes in STT type I. Increased corneal sensitivity was observed in the breed.
O objetivo do estudo foi estabelecer os parâmetros oftálmicos na raça Spitz Alemão anão. Realizaram-se teste lacrimal de Schirmer (TLS), tempo de ruptura do filme lacrimal (TRFL), teste de Jones (TJ), estesiometria, biomicroscopia, tonometria, microscopia especular (MS), oftalmoscopia e ultrassonografia (US) em 48 olhos de 24 cães machos e fêmeas da raça Sptiz Alemão anão, oriundos de canil de criação. Aplicou-se estatística descritiva. As médias e erros padrões encontrados para TLS, TRL, TJ, estesiometria e tonometria foram 24,310±0,448mm/min, 14,570±0,406s., 8,420±1,571min, 3,667±0,157cm e 17,960±0,697mmHg, respectivamente. À biomicroscopia, 43,75% dos olhos apresentaram triquíase de carúncula, 25% cromodacriorreia, 25% entrópio de canto medial e 10,42% distiquíases. À MS, os valores para densidade das células endoteliais, hexagonalidade, área das células endoteliais e espessura corneal central foram 1958,285±36,760 cells/mm², 62,229±2,183%, 519,231±9,853mm² e 0,567±0,006mm, respectivamente. À oftalmoscopia, padrão conforme descrito para cães. Fundo amelanótico foi reportado em 8,33% das retinas. Ao US, os valores identificados para diâmetro axial horizontal, espessura da lente, profundidade das câmaras anterior e posterior foram 16,859±0,148mm, 6,651±0,081mm, 2,673±0,091mm and 7,485±0,101mm. Leves alterações nos parâmetros lacrimais foram influenciadas por alterações palpebrais no TLS tipo I. Sensibilidade corneana aumentada foi identificada na raça.
Assuntos
Animais , Cães , Oftalmologia , Animais de Estimação , Aparelho LacrimalResumo
The objective of this study was to assess healing induction of free skin grafts following transposition of omental flap through a subcutaneous tunnel to the recipient bed. Macroscopic and microscopic evaluations were performed. Nineteen piglets were used. Two surgical wounds were created of each subject. The graft removed from the left side (LS) was placed on the right side (RS) without the omental flap in the graft-bed (control group-CG). On the LS, an omental flap was placed between the graft removed from the RS and the recipient bed (omentum group-OG). Macroscopic evaluations showed edema, which gradually decreased on both groups. Suture dehiscence was highest at day 10 compared to other days in both groups. The CG had a higher incidence of unvitalized tissue compared to OG, although no difference was found among days of postoperative evaluation. The presence of unvitalized tissue was seen on 32% on OG and 53% on CG. Microscopic evaluations revealed higher collagenization, reepithelization, keratinization and less swelling in the OG compared to CG. In conclusion, mesh skin grafts evolved satisfactorily in swine even in newly created bedding without granulation tissue, but with appropriate vascularization. The omentum flap provided better macroscopic and microscopic outcomes regarding graft integration.
O objetivo deste estudo foi verificar a indução da cicatrização de enxertos cutâneos em malha após a utilização de flap de omento transposto através de túnel no subcutâneo até o leito receptor. Avaliações macroscópica e microscópica foram realizadas. Foram utilizados 19 suínos. Duas feridas cirúrgicas foram criadas em cada animal. O enxerto removido do lado esquerdo (LE) foi fixado do lado direito (LD), sem a presença do flap de omento entre o enxerto e o leito receptor (grupo controle - GC). No LE, foi fixado um flap de omento entre o enxerto cutâneo removido do LD e o leito receptor (grupo omento - GO). As avaliações macroscópicas mostraram que o edema diminuiu gradativamente em ambos os grupos. A deiscência foi maior no dia 10 em comparação aos demais dias, em ambos os grupos, entre os diferentes dias de avaliação. Foi verificada a presença de tecido desvitalizado em 32% do GO e em 53% no GC. Foi observada, na avaliação microscópica, maior colagenização, reepitelização, queratinização e menor edema no GO, quando comparado ao GC. Concluiu-se, com este estudo, que enxertos cutâneos em malha evoluíram satisfatoriamente em suínos, mesmo em leito receptor recém-criado e sem presença de tecido de granulação, desde que vascularizado, e que o flap de omento propiciou melhores resultados macro e microscópicos relativos à integração do enxerto.
Assuntos
Animais , Omento/transplante , Suínos/lesões , Neovascularização Fisiológica , Retalhos de Tecido Biológico/veterinária , Procedimentos de Cirurgia Plástica/veterináriaResumo
The aim of this study was to establish normal baseline ERG values of 23 anesthetized deer belonging to 8 neotropical species (Mazama americana, Mazama nemorivaga, Mazama gouazoubira, Mazama nana, Mazama bororo, Ozotocerus bezoarticus, Odocoileus virginianus and Blastocerus dichotomus). Only right eyes were studied. Chemical restraint was performed using xylazine associated with ketamine, IM, for M. americana, M. gouazoubira, M. nemorivaga, M. nana, M. bororo, O. bezoarticus and O. virginianus. A combination of tiletamine/zolazepam diluted in xylazine 2% was used for B. dichotomus individuals. After 20min of dark adaptation, electroretinograms were obtained using a handheld electroretinography (ERG) machine using the QuickRetCheck Protocol at three different light intensities: 0.01cd.s/m2, 3cd.s/m2, and 10cd.s/m2. After light adaptation, photopic phase was recorded. A-wave amplitude recorded during pattern mixed rod/cone response in M. americana was significantly lower when compared to B. dichotomus. No other differences were observed between the species studied. ERG in Neotropical deer is applicable using a portable ERG system and did not show differences among species in relation to the retinal response at different light intensities. Therefore, the lifestyle of the species is more dictated by the selection pressure of the environment than by physiological factors.(AU)
Objetivou-se estabelecer valores de referência para eletrorretinografia (ERG) de 23 cervídeos anestesiados, de oito espécies neotropicais (Mazama americana, Mazama nemorivaga, Mazama gouazoubira, Mazama nana, Mazama bororo, Ozotocerus bezoarticus, Odocoileus virginianus e Blastocerus dichotomus). Somente os olhos direitos foram estudados. A contenção química foi realizada com cetamina/xilazina, IM, nas seguintes espécies: M. americana, M. gouazoubira, M. nemorivaga, M. nana, M. bororo, O. bezoarticus e O. virginianus. Para o B. dichotomus, foi utilizada a associação de tiletamina/zolazepam e xilazina. Após 20 minutos de adaptação ao escuro, os eletrorretinogramas foram obtidos com aparelho portátil de ERG, utilizando-se o protocolo "QuickRet Check", em três intensidades de luz: 0.01cd.s/m2, 3cd.s/m2 e 10cd.s/m2. Após adaptação à luz, realizou-se a fase fotóptica. Os valores para amplitude da onda A durante a resposta padrão mista de cones/bastonetes em M. americana foram significativamente menores quando comparados aos do B. dichotomus. Não foram observadas outras diferenças entre as espécies. A realização de ERG em cervídeos neotropicais é aplicável utilizando-se aparelho portátil e não demonstrou diferenças quanto à resposta retiniana a diferentes intensidades de luz. Dessa forma, o estilo de vida das espécies é ditado mais pela pressão de seleção do ambiente do que por fatores fisiológicos.(AU)
Assuntos
Animais , Antílopes/classificação , Eletrorretinografia/métodos , Animais SelvagensResumo
The aim of this study was to establish normal baseline ERG values of 23 anesthetized deer belonging to 8 neotropical species (Mazama americana, Mazama nemorivaga, Mazama gouazoubira, Mazama nana, Mazama bororo, Ozotocerus bezoarticus, Odocoileus virginianus and Blastocerus dichotomus). Only right eyes were studied. Chemical restraint was performed using xylazine associated with ketamine, IM, for M. americana, M. gouazoubira, M. nemorivaga, M. nana, M. bororo, O. bezoarticus and O. virginianus. A combination of tiletamine/zolazepam diluted in xylazine 2% was used for B. dichotomus individuals. After 20min of dark adaptation, electroretinograms were obtained using a handheld electroretinography (ERG) machine using the QuickRetCheck Protocol at three different light intensities: 0.01cd.s/m2, 3cd.s/m2, and 10cd.s/m2. After light adaptation, photopic phase was recorded. A-wave amplitude recorded during pattern mixed rod/cone response in M. americana was significantly lower when compared to B. dichotomus. No other differences were observed between the species studied. ERG in Neotropical deer is applicable using a portable ERG system and did not show differences among species in relation to the retinal response at different light intensities. Therefore, the lifestyle of the species is more dictated by the selection pressure of the environment than by physiological factors.(AU)
Objetivou-se estabelecer valores de referência para eletrorretinografia (ERG) de 23 cervídeos anestesiados, de oito espécies neotropicais (Mazama americana, Mazama nemorivaga, Mazama gouazoubira, Mazama nana, Mazama bororo, Ozotocerus bezoarticus, Odocoileus virginianus e Blastocerus dichotomus). Somente os olhos direitos foram estudados. A contenção química foi realizada com cetamina/xilazina, IM, nas seguintes espécies: M. americana, M. gouazoubira, M. nemorivaga, M. nana, M. bororo, O. bezoarticus e O. virginianus. Para o B. dichotomus, foi utilizada a associação de tiletamina/zolazepam e xilazina. Após 20 minutos de adaptação ao escuro, os eletrorretinogramas foram obtidos com aparelho portátil de ERG, utilizando-se o protocolo "QuickRet Check", em três intensidades de luz: 0.01cd.s/m2, 3cd.s/m2 e 10cd.s/m2. Após adaptação à luz, realizou-se a fase fotóptica. Os valores para amplitude da onda A durante a resposta padrão mista de cones/bastonetes em M. americana foram significativamente menores quando comparados aos do B. dichotomus. Não foram observadas outras diferenças entre as espécies. A realização de ERG em cervídeos neotropicais é aplicável utilizando-se aparelho portátil e não demonstrou diferenças quanto à resposta retiniana a diferentes intensidades de luz. Dessa forma, o estilo de vida das espécies é ditado mais pela pressão de seleção do ambiente do que por fatores fisiológicos.(AU)
Assuntos
Animais , Antílopes/classificação , Eletrorretinografia/métodos , Animais SelvagensResumo
The aim of this study was to establish normal baseline ERG values of 23 anesthetized deer belonging to 8 neotropical species (Mazama americana, Mazama nemorivaga, Mazama gouazoubira, Mazama nana, Mazama bororo, Ozotocerus bezoarticus, Odocoileus virginianus and Blastocerus dichotomus). Only right eyes were studied. Chemical restraint was performed using xylazine associated with ketamine, IM, for M. americana, M. gouazoubira, M. nemorivaga, M. nana, M. bororo, O. bezoarticus and O. virginianus. A combination of tiletamine/zolazepam diluted in xylazine 2% was used for B. dichotomus individuals. After 20min of dark adaptation, electroretinograms were obtained using a handheld electroretinography (ERG) machine using the QuickRetCheck Protocol at three different light intensities: 0.01cd.s/m2, 3cd.s/m2, and 10cd.s/m2. After light adaptation, photopic phase was recorded. A-wave amplitude recorded during pattern mixed rod/cone response in M. americana was significantly lower when compared to B. dichotomus. No other differences were observed between the species studied. ERG in Neotropical deer is applicable using a portable ERG system and did not show differences among species in relation to the retinal response at different light intensities. Therefore, the lifestyle of the species is more dictated by the selection pressure of the environment than by physiological factors.(AU)
Objetivou-se estabelecer valores de referência para eletrorretinografia (ERG) de 23 cervídeos anestesiados, de oito espécies neotropicais (Mazama americana, Mazama nemorivaga, Mazama gouazoubira, Mazama nana, Mazama bororo, Ozotocerus bezoarticus, Odocoileus virginianus e Blastocerus dichotomus). Somente os olhos direitos foram estudados. A contenção química foi realizada com cetamina/xilazina, IM, nas seguintes espécies: M. americana, M. gouazoubira, M. nemorivaga, M. nana, M. bororo, O. bezoarticus e O. virginianus. Para o B. dichotomus, foi utilizada a associação de tiletamina/zolazepam e xilazina. Após 20 minutos de adaptação ao escuro, os eletrorretinogramas foram obtidos com aparelho portátil de ERG, utilizando-se o protocolo "QuickRet Check", em três intensidades de luz: 0.01cd.s/m2, 3cd.s/m2 e 10cd.s/m2. Após adaptação à luz, realizou-se a fase fotóptica. Os valores para amplitude da onda A durante a resposta padrão mista de cones/bastonetes em M. americana foram significativamente menores quando comparados aos do B. dichotomus. Não foram observadas outras diferenças entre as espécies. A realização de ERG em cervídeos neotropicais é aplicável utilizando-se aparelho portátil e não demonstrou diferenças quanto à resposta retiniana a diferentes intensidades de luz. Dessa forma, o estilo de vida das espécies é ditado mais pela pressão de seleção do ambiente do que por fatores fisiológicos.(AU)
Assuntos
Animais , Antílopes/classificação , Ecossistema , Eletrorretinografia/classificaçãoResumo
Eyes from brachycephalic dogs were studied by acoustic radiation force impulse (ARFI) elastography to establish quantitative and qualitative reference values related to the shape and rigidity of some ocular structures. Eighty-four eyes from 42 adult brachycephalic dogs were included in this study. Animals were subjected to physical, laboratory, and ophthalmic examinations. Following confirmation of good health, the dogs were subjected to ultrasonography and ARFI elastography, emphasizing the optic nerve, ciliary body, and lens. On qualitative elastography, homogeneous characteristics were observed on the ciliary body and optic nerve. Aqueous and vitreous humors were visualized as mosaic-like images. Quantitative elastography showed the mean optic nerve shear wave velocity (SWV) was 1.01±0.27m/s, temporal ciliary body was 0.91±0.24m/s, and nasal ciliary body was 0.91±0.3m/s. The SWV of the lens values were out of range, this value was not detectable by this software. Elastography has proved to be a non-invasive procedure and feasible in dogs. The establishmentof the parameters of degree of rigidity of ocular structures will serve as a baseline for animals with eye disorders. Results may be extrapolated to primary research on the applicability of ARFI in the evaluation of ocular bulb in humans.(AU)
Estruturas oculares de cães braquicéfalos foram estudadas por elastografia acoustic radiation force impulse (ARFI) para estabelecer valores quantitativos e qualitativos de referência relacionados com a forma e a rigidez de algumas estruturas oculares. Foram avaliados 84 olhos de 42 cães braquicéfalos neste estudo. Os animais foram submetidos aos exames físico, laboratorial e aos exames oftalmológicos. Após a confirmação da sanidade dos pacientes, os cães foram submetidos à ultrassonografia e à elastografia ARFI, enfatizando-se o nervo óptico, o corpo ciliar e a lente. Para elastografia qualitativa, foram observadas características homogêneas no corpo ciliar e no nervo óptico. Os humores aquoso e vítreo foram visibilizados como imagens tipo mosaico. A elastografia quantitativa demonstrou velocidades de cisalhamento para nervo óptico de 1,01±0,27m/s, para corpo ciliar temporal de 0,91±0,24m/s e para corpo ciliar nasal de 0,91±0,3m/s. Valores dessas velocidades para lentes apresentaram-se fora do intervalo: X.XXm/s. A elastografia provou ser um procedimento não invasivo e viável para cães. Estabelecidos os parâmetros do grau de rigidez das estruturas oculares, futuramente tais dados servirão como padrão para avaliação de animais com os distúrbios oculares. Os resultados podem ser extrapolados para a pesquisa primária sobre a aplicabilidade da ARFI na avaliação do bulbo ocular em seres humanos.(AU)
Assuntos
Animais , Cães , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Técnicas de Imagem por Elasticidade/veterinária , Anormalidades do Olho/diagnóstico por imagem , Cães/anormalidadesResumo
Eyes from brachycephalic dogs were studied by acoustic radiation force impulse (ARFI) elastography to establish quantitative and qualitative reference values related to the shape and rigidity of some ocular structures. Eighty-four eyes from 42 adult brachycephalic dogs were included in this study. Animals were subjected to physical, laboratory, and ophthalmic examinations. Following confirmation of good health, the dogs were subjected to ultrasonography and ARFI elastography, emphasizing the optic nerve, ciliary body, and lens. On qualitative elastography, homogeneous characteristics were observed on the ciliary body and optic nerve. Aqueous and vitreous humors were visualized as mosaic-like images. Quantitative elastography showed the mean optic nerve shear wave velocity (SWV) was 1.01±0.27m/s, temporal ciliary body was 0.91±0.24m/s, and nasal ciliary body was 0.91±0.3m/s. The SWV of the lens values were out of range, this value was not detectable by this software. Elastography has proved to be a non-invasive procedure and feasible in dogs. The establishmentof the parameters of degree of rigidity of ocular structures will serve as a baseline for animals with eye disorders. Results may be extrapolated to primary research on the applicability of ARFI in the evaluation of ocular bulb in humans.(AU)
Estruturas oculares de cães braquicéfalos foram estudadas por elastografia acoustic radiation force impulse (ARFI) para estabelecer valores quantitativos e qualitativos de referência relacionados com a forma e a rigidez de algumas estruturas oculares. Foram avaliados 84 olhos de 42 cães braquicéfalos neste estudo. Os animais foram submetidos aos exames físico, laboratorial e aos exames oftalmológicos. Após a confirmação da sanidade dos pacientes, os cães foram submetidos à ultrassonografia e à elastografia ARFI, enfatizando-se o nervo óptico, o corpo ciliar e a lente. Para elastografia qualitativa, foram observadas características homogêneas no corpo ciliar e no nervo óptico. Os humores aquoso e vítreo foram visibilizados como imagens tipo mosaico. A elastografia quantitativa demonstrou velocidades de cisalhamento para nervo óptico de 1,01±0,27m/s, para corpo ciliar temporal de 0,91±0,24m/s e para corpo ciliar nasal de 0,91±0,3m/s. Valores dessas velocidades para lentes apresentaram-se fora do intervalo: X.XXm/s. A elastografia provou ser um procedimento não invasivo e viável para cães. Estabelecidos os parâmetros do grau de rigidez das estruturas oculares, futuramente tais dados servirão como padrão para avaliação de animais com os distúrbios oculares. Os resultados podem ser extrapolados para a pesquisa primária sobre a aplicabilidade da ARFI na avaliação do bulbo ocular em seres humanos.(AU)
Assuntos
Animais , Cães , Técnicas de Imagem por Elasticidade , Técnicas de Imagem por Elasticidade/veterinária , Anormalidades do Olho/diagnóstico por imagem , Cães/anormalidadesResumo
The aim of this study was to evaluate changes in intraocular pressure (IOP), pupil size (PS), blood pressure (BP), heart rate (HR), and ECG variables (Pms wave PmV, PR interval, QRS complex, RMV wave and QT intervals) over time during the instillation of 0.5% timolol, 0.5% levobunolol and 0.5% apraclonidine in clinically normal dogs. Ten adult beagles were used. Baseline values were measured at 8a.m., 2p.m. and 8p.m., for three consecutive days. A waiting period of 10 days between the administrations of each drug was established. For 15 consecutive days, the drug being tested was instilled in one eye of each dog twice a day (7a.m. and 7p.m.). The parameters were evaluated at the aforementioned times on days 3, 6, 9, 12 and 15. Data were statistically compared using the Bonferroni test and one-way repeated measures analysis of variance (P<0.05). The Pearson test was used to evaluate any correlation between QT interval, HR and BP. The tested drugs did not find a decrease in IOP. A significant decreased in PS was observed in almost all dogs following levobunolol administration, relative to the control eye. A significant decrease in HR was observed on day 3 following levobunolol treatment, while apraclonidine induced an increase on day 15. Blood pressure was reduced in all measurement time points following apraclonidine treatment. A negative correlation between QT interval and HR was only observed in dogs treated with timolol. In conclusion, levobunolol was the only drug that induced significant alterations in PS. Apraclonidine was the only drug that induced systemic hypotension. Timolol was the only drug to that induced a negative correlation between QT and HR.(AU)
O objetivo deste estudo foi avaliar as mudanças na pressão intraocular (PIO), no diâmetro pupilar (DP), na pressão sanguínea (PS), na frequência cardíaca (FC) e nas variáveis eletrocardiográficas (onda Pms, PmV, intervalo PR, complexo QRS, onda RmV e intervalo QT), ao longo do tempo da instilação do timolol 0,5%, do levobunolol 0,5% e da apraclonidina 0,5% em cães clinicamente normais. Dez Beagles adultos compuseram o estudo. Valores basais foram mensurados às oito,, 14 e 20 horas, durante três dias consecutivos. Foi instituído um período de espera de 10 dias entre a administração de cada fármaco. Durante 15 dias consecutivos, um olho de cada animal recebeu uma gota de cada um deles, a intervalos de 12 horas (às sete e às 19 horas). Os parâmetros foram avaliados nos momentos acima referidos, nos dias três, seis, nove, 12 e 15. Os dados foram comparados estatisticamente empregando-se o teste de Bonferroni após análise de variância para medidas repetidas (P<0,05). Teste de Pearson foi utilizado para correlação entre o intervalo QT com a FC e a PS. Não se encontrou diminuição da PIO. Observou-se redução significativa do DP na quase totalidade dos animais que receberam levobunol, relativamente ao olho controle. Diminuição significativa da FC foi vista ao terceiro dia após a administração do levobunolol, enquanto apraclonidina induziu aumento no 15º dia. A pressão arterial foi reduzida em todos os momentos com a apraclonidina. Observou-se correlação negativa entre o intervalo QT e a FC apenas nos indivíduos tratados com o timolol. Em conclusão, levobunolol foi o único fármaco que induziu alterações significativas no DP. A apraclonidina foi o único fármaco que induziu hipotensão sistêmica significativa. O timolol foi o único a ensejar correlação negativa entre o intervalo QT e a FC.(AU)
Assuntos
Animais , Cães , Pressão Sanguínea , Frequência Cardíaca , Pressão Intraocular , Levobunolol/efeitos adversos , Levobunolol/análise , Timolol/efeitos adversos , Timolol/análise , Análise de Variância , Instilação de Medicamentos , PupilaResumo
The aim of this study was to evaluate changes in intraocular pressure (IOP), pupil size (PS), blood pressure (BP), heart rate (HR), and ECG variables (Pms wave PmV, PR interval, QRS complex, RMV wave and QT intervals) over time during the instillation of 0.5% timolol, 0.5% levobunolol and 0.5% apraclonidine in clinically normal dogs. Ten adult beagles were used. Baseline values were measured at 8a.m., 2p.m. and 8p.m., for three consecutive days. A waiting period of 10 days between the administrations of each drug was established. For 15 consecutive days, the drug being tested was instilled in one eye of each dog twice a day (7a.m. and 7p.m.). The parameters were evaluated at the aforementioned times on days 3, 6, 9, 12 and 15. Data were statistically compared using the Bonferroni test and one-way repeated measures analysis of variance (P<0.05). The Pearson test was used to evaluate any correlation between QT interval, HR and BP. The tested drugs did not find a decrease in IOP. A significant decreased in PS was observed in almost all dogs following levobunolol administration, relative to the control eye. A significant decrease in HR was observed on day 3 following levobunolol treatment, while apraclonidine induced an increase on day 15. Blood pressure was reduced in all measurement time points following apraclonidine treatment. A negative correlation between QT interval and HR was only observed in dogs treated with timolol. In conclusion, levobunolol was the only drug that induced significant alterations in PS. Apraclonidine was the only drug that induced systemic hypotension. Timolol was the only drug to that induced a negative correlation between QT and HR.(AU)
O objetivo deste estudo foi avaliar as mudanças na pressão intraocular (PIO), no diâmetro pupilar (DP), na pressão sanguínea (PS), na frequência cardíaca (FC) e nas variáveis eletrocardiográficas (onda Pms, PmV, intervalo PR, complexo QRS, onda RmV e intervalo QT), ao longo do tempo da instilação do timolol 0,5%, do levobunolol 0,5% e da apraclonidina 0,5% em cães clinicamente normais. Dez Beagles adultos compuseram o estudo. Valores basais foram mensurados às oito,, 14 e 20 horas, durante três dias consecutivos. Foi instituído um período de espera de 10 dias entre a administração de cada fármaco. Durante 15 dias consecutivos, um olho de cada animal recebeu uma gota de cada um deles, a intervalos de 12 horas (às sete e às 19 horas). Os parâmetros foram avaliados nos momentos acima referidos, nos dias três, seis, nove, 12 e 15. Os dados foram comparados estatisticamente empregando-se o teste de Bonferroni após análise de variância para medidas repetidas (P<0,05). Teste de Pearson foi utilizado para correlação entre o intervalo QT com a FC e a PS. Não se encontrou diminuição da PIO. Observou-se redução significativa do DP na quase totalidade dos animais que receberam levobunol, relativamente ao olho controle. Diminuição significativa da FC foi vista ao terceiro dia após a administração do levobunolol, enquanto apraclonidina induziu aumento no 15º dia. A pressão arterial foi reduzida em todos os momentos com a apraclonidina. Observou-se correlação negativa entre o intervalo QT e a FC apenas nos indivíduos tratados com o timolol. Em conclusão, levobunolol foi o único fármaco que induziu alterações significativas no DP. A apraclonidina foi o único fármaco que induziu hipotensão sistêmica significativa. O timolol foi o único a ensejar correlação negativa entre o intervalo QT e a FC.(AU)
Assuntos
Animais , Cães , Timolol/efeitos adversos , Timolol/análise , Levobunolol/efeitos adversos , Levobunolol/análise , Pressão Intraocular , Pressão Sanguínea , Frequência Cardíaca , Pupila , Instilação de Medicamentos , Análise de VariânciaResumo
Sildenafil citrate is a type-5 phosphodiesterase inhibitor (PDE-5), able to inhibit type-6 phosphodiesterase (PDE-6) as well, providing clinical benefits and paraeffects, some of them potentially related to the retina. The effects of the sildenafil on the retrobulbar and retinal circulation were studied in 27 adult male rabbits of the White New Zealand breed. The electric activity of the retina was evaluated before and at the end of the treatments, and immunohistochemistry studies were conducted. An amplitude increase of the b wave was found in the mixed response of cones and rods after 7 days of treatment with sildenafil citrate. However, in the other evaluations and periods, the values did not differ from the basal ones. Through immunohistochemistry, no significant decrease of the expression of PDE-5 and PDE-6 proteins was observed. Based on the results obtained, it is possible to admit that the sildenafil citrate did not change the expression of PDE-5 and PDE-6, neither the electroretinographic activity of the retina of male rabbits of the White New Zealand breed(AU)
O citrato de sildenafil é um inibidor da fosfodiesterase do tipo 5 (PDE-5), capaz de inibir também a fosfodiesterase do tipo 6 (PDE-6), proporcionando benefícios clínicos e paraefeitos, alguns deles potencialmente relacionados à retina. Foram estudados efeitos do sildenafil sobre a circulação retrobulbar e a retiniana em 27 coelhos machos adultos, da raça Nova Zelândia Branco. Avaliou-se a atividade elétrica da retina antes e ao término dos tratamentos e realizaram-se estudos à imunoistoquímica. Encontrou-se aumento da amplitude da onda b na resposta mista de cones e de bastonetes, após 7 dias de tratamento com citrato de sildenafil. Entretanto, nas demais avaliações e períodos, os valores não divergiram dos basais. Pela imunoistoquímica, não se observou diminuição significativa da expressão das proteínas PDE-5 e PDE-6. Com base nos resultados obtidos, é possível admitir que o citrato de sildenafil não alterou a expressão de PDE-5 e PDE-6, tampouco, a atividade eletrorretinográfica da retina de coelhos machos da raça Nova Zelândia Branco(AU)
Assuntos
Animais , Masculino , Coelhos , Retina/anatomia & histologia , Citrato de Sildenafila/efeitos adversos , Eletrorretinografia/veterinária , Imuno-Histoquímica/veterinária , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/veterináriaResumo
The purpose of this study was to evaluate the macroscopy and microstructure of a double setting alpha-tricalcium phosphate bone cement sphere provided with interconnection channels (alpha-TCP-i), as well as the integration of the implant with the rabbits' orbital tissue, through macroscopic analysis and histopathology. The external and internal surfaces of the alpha-TCP-i were evaluated macroscopically and by electron microscopy. Twelve New Zealand rabbits received 12mm implants of alpha-TCP-i following enucleation of the left eye. The clinical assessment was undertaken daily during the first 15 days, followed by fortnightly assessment until the end of the study period. For the morphological analysis, exenteration was performed in 3 animals per experimental period (15, 45, 90 and 180 days). The external and internal surfaces of the implant appeared solid, smooth and compact, with six channels which interconnected centrally. The micro-architecture was characterized by the formation of columns of hexagonal crystals. No signs of infection, exposure, dehiscence of sutures or extrusion of the implant were noted in any of the animals during the entire period of the study. The morphological evaluation demonstrated the presence of a thin capsule around the implant, from whence appeared fibro-vascular projections, which penetrated it through the interconnecting channels. In the first days after the insertion of the implant, an intense inflammatory reaction was noted. At 180 days, however, there were no signs of inflammation. The alpha-tricalcium phosphate cement implant was well tolerated in this rabbit model and appeared to be relatively inert with some fibrovascular ingrowth through the large channels.(AU)
Avaliaram-se a macroscopia e a microestrutura de esferas compostas por cimento ósseo de alfa-fosfato tricálcico de dupla pega munido de canais de interconexão (alfa-TCP-i) e a integração do implante ao tecido orbital de coelhos através de análise macroscópica e histopatológica. A superfície interna e externa do alfa-TCP-i foi avaliada macroscopicamente e por microscopia eletrônica. Após enucleação do bulbo ocular esquerdo, 12 coelhos da raça Nova Zelândia receberam implantes do alfa-TCP-i com 12mm de diâmetro. A avaliação clínica foi realizada diariamente nos primeiros 15 dias e depois a cada quinze dias até o fim do período de estudo. Para análise morfológica, seguiu-se a exenteração de três animais por período experimental (15, 45, 90 e 180 dias). As superfícies externa e interna do implante mostraram-se compactas, sólidas e lisas, com seis canais que se interconectavam centralmente. A microarquitetura caracterizou-se pela formação de colunas de cristais hexagonais. Sinais de infecção, exposição, deiscência de sutura ou extrusão não foram notados em nenhum dos animais durante o período de estudo. A análise morfológica revelou a presença de fina cápsula ao redor do implante de onde surgiram projeções fibrovasculares que o penetraram através dos canais de interconexão. Nos primeiros dias após a inserção das esferas, notou-se intensa reação inflamatória que se mostrou ausente aos 180 dias. O implante do cimento de alfa-fosfato tricálcico foi bem tolerado em coelhos, mostrou-se relativamente inerte e permitiu a infiltração de tecido fibrovascular através dos canais de interconexão.(AU)
Assuntos
Animais , Coelhos , Anormalidades do Olho/diagnóstico , Anormalidades do Olho/reabilitação , Próteses e ImplantesResumo
The objectives of this study were to compare surgical techniques and the effects of using n-butyl 2-cyanoacrylate and bovine amniotic membrane to repair perforated lesions in corneas. Penetrating keratoplasty was performed in sixty New Zealand White rabbits under general anesthesia. Group 1 (G1) was treated with n-butyl 2-cyanoacrylate, group 2 (G2) received a fragment of amniotic membrane through the anterior chamber and application of n-butyl 2-cyanoacrylate over the lesion, group 3 (G3) was treated with the same technique as G2 with the addition of an amniotic membrane bandage covering the cornea and sutured in the limbus region, and group 4 (G4) was treated with an amniotic membrane sutured to the lesion and an amniotic membrane bandage sutured in the limbus region. Clinical, histological and histomorphometric examinations of the corneas were performed. The membrane acted as a barrier for aqueous humor in G2 and G3, thereby keeping the surface dry for adhesive application; it also prevented the adhesive from contacting intraocular structures. The groups treated with amniotic membrane and surgical adhesive showed better results than the groups treated with either material alone. Thus, the combination of the membrane with the adhesive is recommended for this type of lesion.(AU)
Os objetivos deste estudo foram comparar técnicas cirúrgicas e efeitos do n-butil 2-cianoacrilato e da membrana amniótica bovina na reparação de lesões perfuradas em córneas. Sessenta coelhos da raça Nova Zelândia Branca foram submetidos à ceratoplastia penetrante sob anestesia geral. O grupo 1 (G1) foi tratado com n-butil 2-cianoacrilato; o grupo 2 (G2) recebeu um fragmento de membrana amniótica pela câmara anterior e aplicação de n-butil 2-cianoacrilato sobre a lesão; o grupo 3 (G3) foi tratado com a mesma técnica aplicada ao G2, adicionando-se uma bandagem de membrana amniótica cobrindo a córnea e suturada à região do limbo; e o grupo 4 (G4) foi tratado com membrana amniótica suturada nas bordas da lesão e bandagem de membrana amniótica suturada na região do limbo. Foram realizados exames clínico, histológico e histomorfométrico. A membrana atuou como barreira contra o extravasamento do humor aquoso nos grupos 2 e 3, manteve a superfície seca para posterior aplicação do adesivo e impediu o contato do adesivo com as estruturas intraoculares. Os grupos tratados com o adesivo associado à membrana amniótica demonstraram melhores resultados do que aqueles tratados com cada material isoladamente. Assim, a combinação da membrana com o adesivo é indicada neste tipo de lesão.(AU)
Assuntos
Animais , Coelhos/cirurgia , Ceratoplastia Penetrante/veterinária , Cianoacrilatos/uso terapêutico , Humor Aquoso , Córnea/lesões , Adesivos Teciduais , ÂmnioResumo
This study aimed to evaluate the microbiota of donor rabbit corneas stored for tectonic transplantation purposes. Swabs from both corneas of 20 rabbits were carefully collected and submitted to microorganism isolation and identification. After this first swab collection, rabbits were euthanized for reasons other than this project and the eyes were enucleated. The corneas were collected and stored to compose the cornea tissue bank. Corneas were stored in a 0.3% tobramycin solution at -20ºC. After 30 days, the corneas were thawed at room temperature and removed from the antibiotic. New swabs were obtained from the corneas and submitted to microorganism isolation and identification. Gram positive organisms were predominant in the rabbit corneal flora before storage and the Staphylococcus sp. was the most common microorganism isolated from those samples. No growth was observed on the samples collected after storage. The methods used for collection and storage of the corneas were efficient to constitute a sterile donor corneal tissue bank.(AU)
Analisaram-se córneas armazenadas para transplantes tectônicos usando-se suabes coletados de 20 coelhos, visando ao isolamento e à identificação de microrganismos. Após a coleta das amostras, os coelhos foram submetidos à eutanásia, por razões alheias ao estudo, e enucleados. As córneas foram coletadas e armazenadas a fim de se constituir o banco de córneas. O armazenamento deu-se em solução de tobramicina 0,3% a -20ºC, por 30 dias. Após esse período, as córneas foram descongeladas à temperatura ambiente e removidas da solução de antibiótico. Novos suabes foram coletados e submetidos ao isolamento e à identificação dos microrganismos. A flora corneal mostrou-se predominantemente composta por bactérias Gram positivas, sendo o Staphylococcus sp. o mais identificado. Não se verificou crescimento de colônias bacterianas ou fúngicas nas amostras após o armazenamento. Considerando-se a maneira como a pesquisa foi concebida e as injunções do meio em que ela foi realizada, há como admitir, pela ausência de crescimento microbiano nas amostras armazenadas, que a técnica de armazenamento empregada é segura para a estocagem de córneas destinadas a transplantes.(AU)
Assuntos
Animais , Coelhos , Transplante de Córnea/normas , Transplante de Córnea/veterinária , Microbiologia/normas , Microbiota , Staphylococcus , Eutanásia AnimalResumo
The anesthetics effects of aqueous extract of Ottonia martiana leaves were studied on the ocular surface of healthy beagle dogs. The dogs were divided in three groups (n=15): control group (CG), proxymetacaine group (PG) and Ottonia group (OG), which were treated with 0.9% saline, 0.5% proxymetacaine hydrochloride ophthalmic solution and O. martiana extract respectively. An oftalmic evaluation was performed before the treatments. Eye drops were instilled at time 0 (T0) and 3 minutes later (T3). Axial corneal sensitivity was evaluated by esthesiometry 5 and 10 minutes after T0. Tear production and intraocular pressure were evaluated 10 minutes after T0. Slit lamp biomicroscopy was performed 10 and 20 minutes after T0 and the eyes were stained with fluorescein 20 minutes after T0. The STT was reduced in PG. Conjunctival hyperemia was observed in 13 animals from PG and constituted the only ocular alteration observed during the study. Esthesiometry revealed a decreased corneal sensitivity for PG and OG. Those results show that the O. martiana extract acts reducing corneal sensitivity in dogs. Moreover, its use does not decrease the tear production and does not cause any clinical ophthalmic alteration.(AU)
Estudaram-se os efeitos do extrato das folhas de Ottonia martiana sobre a superfície ocular de cães hígidos da raça Beagle. Compuseram-se três grupos de tratamento (n=15): grupo controle (GC), grupo proximetacaína (GP) e grupo Ottonia (GO), tratados, respectivamente, com solução fisiológica, colírio de cloridrato de proximetacaína a 0,5% e extrato de O. martiana. Após avaliação oftálmica inicial, os tratamentos foram realizados no tempo 0 (T0) e decorridos 3min (T3). Avaliaram-se a sensibilidade axial da córnea por estesiometria (T5 e T10) e a produção lacrimal e a pressão ocular (T10). Realizaram-se a biomicroscopia com lâmpada em fenda (T10 e T20), e o teste do tingimento pela fluoresceína (T20). Relativamente ao teste de Schirmer, observou-se diminuição nos cães do GP. Houve alteração clínica somente nos do GP, em que 13 animais apresentaram hiperemia conjuntival. Relativamente à estesiometria, houve diminuição da sensibilidade corneal nos animais do GP e do GO. Admite-se que o extrato de O. martiana age diminuindo a sensibilidade corneal em cães e que sua utilização não diminui a produção lacrimal, tampouco causa alterações clínicas oftálmicas.(AU)
Assuntos
Animais , Cães , Piperaceae , Cães/lesões , Soluções Oftálmicas , Hiperemia/veterinária , Pressão Intraocular , Fluoresceína/uso terapêuticoResumo
Leishmaniose é uma enfermidade multissistêmica cujas manifestações clínicas são extremamente variáveis. Em cães sinais clínicos oftálmicos são relativamente frequentes, ainda que outros sinais sistêmicos não sejam identificados. Atualmente, o diagnóstico da doença baseia-se em métodos parasitológicos, sorológicos e moleculares, mas, até o momento, a identificação de formas amastigotas desse parasito em esfregaços feitos a partir de suabes conjuntivais não é empregada rotineiramente. Valendo-se de cães sorologicamente positivos para leishmaniose, portadores (G1) ou não (G2) de alterações oftálmicas, este estudo avaliou a viabilidade do esfregaço a partir de suabe conjuntival como método de diagnóstico para a enfermidade. O exame suprarreferido foi positivo em 60% dos animais do G1 e 38,1% do G2, no entanto não houve diferença estatisticamente significativa em relação à positividade nos dois grupos (P=0,2167). Os dados apontam para uma tendência de os cães com leishmaniose e com sinais oftálmicos serem positivos ao exame parasitológico de esfregaço a partir de suabe conjuntival, podendo esse método ser útil no diagnóstico parasitológico da leishmaniose canina.(AU)
Leishmaniasisis is a multisystemic disease with varying clinical presentations. In dogs, alterations in the eyes are commonly observed even in animals with no systemic signs. The diagnosis of leishmaniasis is currently based on parasitological, serological and molecular methods, although the identification of amastigote forms of this parasite in conjunctival swabs is not a routine technique in clinical practice. Serologically positive dogs for leishmaniasis presenting (G1) or not (G2) ocular alterations were enrolled in this study to evaluate the conjunctival swab as a method for the diagnosis of this disease. The parasitological evaluation of the swabs disclosed 60% positivity for dogs in group 1, whereas only 38.1% of dogs in group 2 were positive. However, no significant difference was documented between the two groups (P=0.2167). Our data suggest a tendency for dogs with ocular signs to be tested positive in the conjunctival swab exam, thus, this method is useful in the diagnosis of canine leishmaniasis.(AU)
Assuntos
Animais , Cães , Leishmaniose/parasitologia , Leishmaniose/veterinária , Oftalmopatias/diagnóstico , Túnica Conjuntiva/parasitologia , Túnica Conjuntiva/citologia , Linfonodos/parasitologia , Avaliação de Sintomas/veterinária , Oftalmopatias/veterináriaResumo
The study aimed to evaluate tear production by means of modified Schirmer tear tes-1 (mSTT-1) in neonate cats. Likewise, correlation between mSTT-1 and STT-1 was assessed in vitro. Standard SST strips were cut in half and after eye lid opening, tear production of neonates (n=15) was daily measured in both eyes (mSTT-1), until the 7th day, and at day 14, 21, and 28. Animals were daily weighted until 28 days of age. Results were compared statistically (P<0.05). During the first 7 days, the overall mSTT-1 mean was 0.76 wetting/minute. Significant differences between right and left eyes were not observed at any time point (P=1.00). Tear secretion increased significantly, from the 14th to 28th day, in comparison with 7 first days (P<0.05). Positive correlation between maturity parameters and tear secretion was observed (P<0.0001). Distance between slopes of each strip changed significantly (P<0.0001). It was concluded that tear secretion in the neonatal period of cats is very below the reference values described for young and adults of the same species. It is not possible to extrapolate results obtained with mSTT-1 to standard STT-1.(AU)
Objetivou-se avaliar a produção lacrimal, por meio do teste da lágrima de Schirmer-1 modificado (TLS-1m) em gatos neonatos. Outrossim, estabelecer in vitro a existência de correlação entre o TLS e o TLS-1m. Tiras pa-dronizadas para realização do TLS foram partidas ao meio e após a abertura das pálpebras, a produção lacrimal dos neonatos (n=15) foi aferida em ambos os olhos (TLS-1m), diariamente, até o sétimo e aos 14, 21 e 28 dias. Os animais foram pesados diariamente até os 28 dias de idade. Os resultados foram comparados estatisticamente (p<0,05). Durante os primeiros sete dias de avaliação, a média geral obtida pelo TLS-1m foi de 0,76±0,08 mm/minuto. Não se constatou diferença significativa entre os olhos direito e esquerdo, em nenhum dos períodos avaliados (p=1,00). A produção lacrimal elevou-se significativamente, do 14º até o 28º dia, comparativamente aos primeiros sete dias (p<0,05). Observou-se correlação positiva entre parâmetros de maturidade e a produção lacrimal (p<0,0001). A distância entre as linhas de cada tira foi significativa (p<0,0001). Conclui-se que a produção lacrimal no período neonatal em gatos é bem inferior aos valores de referência descritos para adultos e jovens da mesma espécie. Não é possível extrapolar valores obtidos com o TLS-1 modificado para o TLS-1 padrão.(AU)
Assuntos
Animais , Técnicas de Diagnóstico Oftalmológico/efeitos adversos , Técnicas de Diagnóstico Oftalmológico/veterináriaResumo
A case of a two-year-old male Pinscher with a history of discomfort in the right eye was reported. The left eye had been enucleated by the referring veterinarian due to the same symptom with unsuccessful clinical treatment. The Schirmer tear test value was elevated and a decreased intraocular pressure was observed by applanation tonometry. Biomicroscopy revealed profuse corneal edema and keratoconus and fluorescein staining was negative. Gonioscopy and ophthalmoscopy did not provide any relevant data due to the corneal alterations. Bullous keratopathy was diagnosed. Surgery was performed in two steps: 1) superficial keratectomy and 360º conjunctival flap, and 2) superficial keratectomy to restore corneal transparency. Thirty days after the second superficial keratectomy, the third eyelid flap was removed. Conjunctivalization of the upper nasal quadrant of the cornea was observed. The axial portion of the cornea was transparent and vision was restored.(AU)
Relata-se o caso ocorrido em um cão, da raça Pinscher, com dois anos de idade e histórico de desconforto no olho direito. O olho esquerdo havia sido enucleado por outro profissional, por apresentar os mesmos sinais, cujo tratamento clínico instituído não lograra êxito. O valor do teste da lágrima de Schirmer encontrava-se aumentado e identificou-se diminuição da pressão intraocular à tonometria de aplanação. Observaram-se, à biomicroscopia, edema corneal profuso e ceratocone, e o teste da fluoresceína foi negativo. Gonioscopia e oftalmoscopia não lograram fornecer dados relevantes dadas as condições da córnea. Diagnosticou-se ceratite bolhosa. Optou-se pelo tratamento cirúrgico, que fora realizado em duas etapas: 1- ceratectomia superficial e "flap" conjuntival de 360º; 2- ceratectomia superficial para devolver transparência à córnea. Transcorridos 30 dias da segunda ceratectomia superficial, o "flap" de terceira pálpebra foi desfeito. Observou-se conjuntivalização do quadrante nasal superior da córnea, córnea clara no eixo visual e retorno da visão.(AU)
Assuntos
Animais , Cães , Ceratite/veterinária , Ceratectomia Fotorrefrativa , Técnicas de Diagnóstico Oftalmológico/veterináriaResumo
This study aimed to evaluate the effectiveness of a computer-assisted ultrasound analysis of senile dogs cataractous lens and identify its correlation to phacoemulsification surgical parameters. Simultaneous A- and B- mode ultrasonic evaluation of the lens was performed on 15 dogs with cataract. A computer-assisted image analysis was used to objectively calculate the lens echogenicity. Following ultrasonographic examination the cataracts were removed by phacoemulsification and the ultrasonographic and phacoemulsification findings were compared to identify possible correlations. Lens echogenicity obtained by the computer-assisted ultrasonographic analysis correlated to the phacoemulsification time, such that the whiter the ultrasound image, the longer was the phacoemulsification time. The B-mode ultrasonography was helpful for the prediction of lens opacity location, but not predictive of lens hardness.(AU)
Avaliou-se a eficácia da análise ultrassonográfica, assistida por computador, da lente cataratogênica senil de cães e identificou-se sua correlação com parâmetros da facoemulsificação. A avaliação ultrassonográfica da lente em modos A e B simultâneos foi realizada em 15 cães portadores de catarata. Procedeu-se à análise das imagens, assistida por computador. Posteriormente, os olhos selecionados foram submetidos à facoemulsificação. Os achados ultrassonográficos e a facoemulsificação foram comparados visando à identificação de possíveis correlações. A ecogenicidade obtida por meio da análise ultrassonográfica correlacionou-se diretamente com o tempo de facoemulsificação, de maneira que quanto mais branca a imagem ultrassonográfica, maior o tempo de facoemulsificação. A ultrassonografia em modo-B auxiliou na predição da localização das opacidades lenticulares, porém não auxiliou na predição da dureza da lente.(AU)
Assuntos
Cães , Cães/anatomia & histologia , Catarata/veterinária , EnvelhecimentoResumo
The evaluation of lens by ultrasonography, previously to phacoemulsification, can offer relevant information, markedly such as aspects and dimensions, allowing design safer surgical strategies with enhanced outcomes. Within the contents of this research, the biometry was performed in lens of dogs with senile immature, mature, and diabetic cataracts, previously to phacoemulsification, using mode A and mode B ultrasonography, simultaneously. The values obtained for axial diameter of the eyes, anterior chamber, lens, and vitreous chamber were, respectively, 19.22mm, 2.35mm, 7.94mm, and 8.94mm. Diabetic cataractous lens were larger (8.90mm), compared to mature cataract (8.12mm). Lens with immature cataract were smaller in dimension than those with mature and diabetic cataracts.(AU)
A avaliação da lente pela ultrassonografia, previamente à facoemulsificação, pode fornecer informações relevantes, notadamente, quanto ao seu aspecto e dimensões, que permitem delinear estratégias cirúrgicas mais seguras e com melhores resultados. Nesta pesquisa, realizou-se a biometria da lente de cães acometidos por catarata senil imatura, madura ou diabética, previamente à facoemulsificação, valendo-se da ultrassonografia em modo A e B, simultaneamente. Os valores obtidos para o diâmetro axial do bulbo do olho, câmara anterior, lente e câmara vítrea foram, respectivamente, 19,22mm, 2,35mm, 7,94mm e 8,94mm. Lentes cataratogênicas pertencentes a animais diabéticos apresentaram dimensões maiores (8,90mm), comparativamente àquelas que apresentavam catarata madura (8,12mm). Lentes acometidas por catarata imatura apresentaram menor dimensão (7,06mm), comparativamente às demais.(AU)
Assuntos
Animais , Masculino , Feminino , Adulto , Idoso , Cães , Cristalino , Catarata/veterinária , Ultrassonografia/veterinária , Técnicas de Diagnóstico Oftalmológico/veterinária , Biometria/métodos , CãesResumo
A- and B-modes ultrasonographic changes in the thickness of various structures of the eyeball in male and female English Cocker Spaniel dogs with and without nondiabetic cataracts were evaluated. Sixteen dogs with cataracts (32 eyes) and seven normal dogs (14 eyes) older than eight years were selected. A- and B-modes ultrasonography was performed with a 10MHz transducer. Data was statistically evaluated by one way ANOVA. Mean and standard deviations of various ocular structures for dogs with and without cataracts were, respectively, anterior chamber: 3.041±0.828mm, 3.373±1.040mm; lens: 6.817±1.117mm, 7.062±0.477mm; vitreous: 10.056±0.754mm, 9.523±0.705mm; and axial length: 19.909±1.103mm, 19.958±1.050mm. Ocular measurements between right and left eyes, males and females, as well as in eyes with and without cataract were not different (P>0.05).(AU)
Avaliaram-se as alterações na dimensão de estruturas do bulbo do olho de cães da raça Cocker Spaniel Inglês, machos e fêmeas, com ou sem catarata não diabética. Dezesseis animais com catarata (n = 32 olhos) com idade acima de oito anos e um grupo-controle, composto por sete cães, com idades também acima de oito anos, sem catarata (n = 14 olhos) compuseram a pesquisa. Realizou-se ultrassonografia transcorneana nos modos A e B com transdutor de 10MHz. Os dados foram submetidos à análise de variância e ao teste Tukey para comparação de médias. O comprimento axial do bulbo do olho dos animais com catarata e dos animais do grupo-controle foram, respectivamente, 19,909±1,103mm e 19,958±1,050mm. Para a câmara anterior, encontraram-se 3,041±0,828mm; 3,373±1,040mm, respectivamente. Para o diâmetro lenticular, os valores foram 6,817±1,117mm e 7,062±0,477mm, respectivamente, e para o segmento posterior, 10,056±0,754mm e 9,523±0,705mm, respectivamente. Não se encontraram diferenças significativas entre olhos com catarata e do grupo-controle, tampouco entre machos e fêmeas com e sem catarata, nem entre olhos direitos e esquerdos (P>0,05).(AU)