Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.022
Filtrar
1.
Arq. bras. med. vet. zootec. (Online) ; 75(4): 561-570, July-Aug. 2023. tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1447344

Resumo

The objective of this study was to demonstrate the effectiveness of the single transphyseal screw technique in foals diagnosed with carpal valgus deviation. This study included 22 thoroughbred animals of both sexes, with a mean age of 30 days. All animals had a carpal valgus deviation >5° with irregular development of the distal epiphysis of the radius. All animals were surgically treated to correct the carpal valgus deviation by creating a bridge using a single transphyseal screw. Surgical intervention was performed for 40 limbs, comprising 19 right and 21 left thoracic limbs. This corresponded to four animals with carpal valgus deviation >5° in only one of the limbs and 18 with the deviation in both limbs. It was observed that 38/40 treated limbs (95%) achieved normal angulation according to the literature, i.e., angulation between 0° and 5°. No statistical differences were observed between the affected limbs. The single transphyseal screw technique can be used for the correction of carpal valgus deviation in foals. It is indicated in animals with an average age of 30 days (20-55 days), as its main advantages are rapid application, simple execution, and limited trans- and post-surgical complications, making it an effective procedure in thoroughbred foals with carpal valgus angular deviation.


O objetivo do presente estudo foi demonstrar a viabilidade da aplicação da técnica de parafuso único transfiseal em potros, com diagnóstico de desvio valgo do carpo. Foram selecionados 22 animais, da raça PSI, com idade média de 30 dias, de ambos os sexos. Todos os animais apresentavam desvio valgo do carpo acima de cinco graus, com desenvolvimento irregular da epífise distal do rádio. Os animais foram submetidos à cirurgia corretiva para o desvio valgo do carpo por meio da realização de ponte com um único parafuso transfiseal. Foram submetidos à intervenção cirúrgica 40 membros, divididos entre membros torácicos direito e esquerdo 19 e 21, respectivamente, que corresponderam a quatro animais com desvio acima de 5 graus valgo do carpo em apenas um dos membros e 18 animais com o procedimento nos dois membros. Observou-se que 38 dos 40 membros tratados, ou seja, 95%, retornaram a uma angulação considerada normal, entre zero e cinco graus Dois animais apresentaram infecção do implante, de maneira que eles reduziram a angulação, porém não o suficiente para enquadrá-los na angulação normal estabelecida pela literatura. Não houve diferença estatística entre os membros acometidos. A técnica de aplicação do único parafuso transfiseal pode ser indicada para correção do desvio valgo do carpo em potros. Deve ser indicada em animais com idade média de 30 dias (20 a 55 dias de vida), por ter como principais vantagens aplicação rápida, execução simples e com limitadas intercorrências trans e pós-cirúrgicas.


Assuntos
Animais , Próteses e Implantes/veterinária , Doenças dos Cavalos
2.
Ciênc. rural (Online) ; 53(6): 1-12, 2023. ilus, tab
Artigo em Inglês | VETINDEX | ID: biblio-1413099

Resumo

Cervical spondylomyelopathy (CSM) is a disease that affects mostly large- and giant-breed dogs. It is characterized by abnormalities of the cervical spine that may cause damage to the spinal cord and nerve roots. Cervical disc arthroplasty has been proposed as a treatment option in veterinary medicine. The current study evaluated the main stresses in a novel canine vertebral disc prosthesis and vertebral bodies using finite element analysis. Two experimental groups were created based on the material used for the prosthesis: stainless steel group (SSG) and titanium alloy group (TAG). Vertebral and prosthetic average equivalents von-Mises stress (VMS) and minimum principal stress (MiPS) were assessed while compressive, tensile, and lateral bending shear loads were applied. The stainless steel group had greater VMS distribution on all the evaluated parameters while the titanium alloy group had greater MiPS. Stresses were more concentrated on the lateral and ventral surfaces of the vertebral bodies than on their endplates. The average prosthetic stresses were more concentrated on the bone/implant contact surface than on the prosthesis/screw interface. Maximum stresses were concentrated in the screws' cranial surface. The novel prosthesis allows even distribution along the vertebral body. Comparing prosthesis materials, titanium alloy was marginally superior regarding average stresses in all directions and should be less likely to suffer subsidence.


Espondilomielopatia cervical (EMC) é uma doença que geralmente afeta cães de raças grandes e gigantes. Ela é caracterizada por anormalidades da coluna cervical que podem causar danos à medula espinhal ou às raízes nervosas. Artroplastia cervical com prótese de disco tem sido proposta como opção de tratamento na medicina veterinária. O presente estudo teve como objetivo avaliar os principais estresses em uma nova prótese de disco intervertebral canina e corpos vertebrais por meio da análise de elementos finitos. Foram compostos dois grupos experimentais que representaram o material constituinte da nova prótese: grupos aço inoxidável (SSG) e o liga de titânio (TAG). Tensões equivalente de von-Mises (VMS) e tensão principal mínima (MiPS) média foram avaliadas sob forças de compressão, tração e torção para vértebras e prótese. O grupo SSG teve maior distribuição de VMS para todos parâmetros avaliados, enquanto o grupo TAG teve maior MiPS. Estresses estiveram mais concentrados nas superfícies lateral e ventral dos corpos vertebrais do que nas placas terminais. Os estresses médios da prótese foram mais concentrados na superfície de contato osso/implante do que na interface prótese/parafuso. Estresses máximos foram concentrados na superfície cranial do parafuso. A nova prótese permitiu distribuição uniforme do estresse ao longo do corpo vertebral. Comparando os materiais da prótese, a liga de titânio foi marginalmente superior quanto aos estresses médios em todas as direções, sendo menos provável que sofra afundamento da prótese.


Assuntos
Animais , Cães , Artroplastia/veterinária , Próteses e Implantes/veterinária , Coluna Vertebral , Manipulação da Coluna/veterinária , Doenças do Cão
3.
Ciênc. rural (Online) ; 53(6): e20210893, 2023. tab, graf
Artigo em Inglês | LILACS-Express | VETINDEX | ID: biblio-1404259

Resumo

ABSTRACT: Cervical spondylomyelopathy (CSM) is a disease that affects mostly large- and giant-breed dogs. It is characterized by abnormalities of the cervical spine that may cause damage to the spinal cord and nerve roots. Cervical disc arthroplasty has been proposed as a treatment option in veterinary medicine. The current study evaluated the main stresses in a novel canine vertebral disc prosthesis and vertebral bodies using finite element analysis. Two experimental groups were created based on the material used for the prosthesis: stainless steel group (SSG) and titanium alloy group (TAG). Vertebral and prosthetic average equivalents von-Mises stress (VMS) and minimum principal stress (MiPS) were assessed while compressive, tensile, and lateral bending shear loads were applied. The stainless steel group had greater VMS distribution on all the evaluated parameters while the titanium alloy group had greater MiPS. Stresses were more concentrated on the lateral and ventral surfaces of the vertebral bodies than on their endplates. The average prosthetic stresses were more concentrated on the bone/implant contact surface than on the prosthesis/screw interface. Maximum stresses were concentrated in the screws' cranial surface. The novel prosthesis allows even distribution along the vertebral body. Comparing prosthesis materials, titanium alloy was marginally superior regarding average stresses in all directions and should be less likely to suffer subsidence.


RESUMO: Espondilomielopatia cervical (EMC) é uma doença que geralmente afeta cães de raças grandes e gigantes. Ela é caracterizada por anormalidades da coluna cervical que podem causar danos à medula espinhal ou às raízes nervosas. Artroplastia cervical com prótese de disco tem sido proposta como opção de tratamento na medicina veterinária. O presente estudo teve como objetivo avaliar os principais estresses em uma nova prótese de disco intervertebral canina e corpos vertebrais por meio da análise de elementos finitos. Foram compostos dois grupos experimentais que representaram o material constituinte da nova prótese: grupos aço inoxidável (SSG) e o liga de titânio (TAG). Tensões equivalente de von-Mises (VMS) e tensão principal mínima (MiPS) média foram avaliadas sob forças de compressão, tração e torção para vértebras e prótese. O grupo SSG teve maior distribuição de VMS para todos parâmetros avaliados, enquanto o grupo TAG teve maior MiPS. Estresses estiveram mais concentrados nas superfícies lateral e ventral dos corpos vertebrais do que nas placas terminais. Os estresses médios da prótese foram mais concentrados na superfície de contato osso/implante do que na interface prótese/parafuso. Estresses máximos foram concentrados na superfície cranial do parafuso. A nova prótese permitiu distribuição uniforme do estresse ao longo do corpo vertebral. Comparando os materiais da prótese, a liga de titânio foi marginalmente superior quanto aos estresses médios em todas as direções, sendo menos provável que sofra afundamento da prótese.

4.
Arq. bras. med. vet. zootec. (Online) ; 75(4): 709-714, July-Aug. 2023. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1447348

Resumo

The black swan (Cygnus atratus, LATHAM, 1790) is a bird kept as an ornamental in zoos. Because of their long beaks they tend to have a reserved prognosis in musculoskeletal disorders such as beak trauma, secondary to skull bone fractures, presenting irreversible lesions. The aim of this report is present a clinical surgical innovation in the repair of a black swan's gnathotheca fissure with the application of non-conventional materials used. It was observed that one of the swans kept in a zoo display area had difficulty feeding, with associated weight loss. It was observed tissue loss and a lacerative lesion in the caudal sublingual region of its beak. The lesion was corrected by a separate simple suture in the cranial region of the beak and with a x-clamping using steel surgical wire and the application of dental resin in the distal region to perform a sustentation bridge in the beak end-gap. After 12 days, the animal was able to feed again and remained perfectly adapted to the restoration, reestablishing the anatomical and physiological function of its beak.


O cisne-negro (Cygnus atratus, Latham, 1790) é uma ave mantida como ornamental em zoológicos. Por apresentar bicos longos, tende a ter prognóstico reservado em afecções musculoesqueléticas, como traumas de bico secundários e fraturas de ossos do crânio, com lesões irreversíveis. O objetivo deste relato é apresentar uma inovação clínica cirúrgica no reparo de fissura na gnatoteca de um cisne-negro, com a utilização de materiais não convencionais. Observou-se que um dos cisnes mantidos em uma área de exibição de um zoológico apresentava dificuldade para se alimentar, com perda de peso associada. Constatou-se perda tecidual e lesão lacerativa na região sublingual caudal de seu bico. A lesão foi corrigida por meio de sutura simples separada na região cranial do bico e posterior sutura em x com fio cirúrgico de aço, finalizando com aplicação de resina odontológica na região distal para realização de ponte de sustentação do bico. Após 12 dias, o animal conseguiu se alimentar novamente e se manteve perfeitamente adaptado à restauração, restabelecendo a função anatômica e fisiológica de seu bico.


Assuntos
Animais , Próteses e Implantes/veterinária , Bico/lesões , Doenças das Aves , Aves/cirurgia
5.
Ciênc. rural (Online) ; 53(12): e20220027, 2023. ilus, tab
Artigo em Inglês | VETINDEX | ID: biblio-1434389

Resumo

Cervical arthroplasty with disc prosthesis has been proposed as a treatment option for dogs with Cervical Spondylomyelopathy. The present study developed a novel vertebral disc prosthesis for dogs. Sixteen Functional Spinal Units (C5-C6) were collected from dog cadavers with body weights ranging between 25 and 35 kg, and their vertebral measurements were used to design a prosthetic disc. The sizing of the prosthesis was performed based on the averages of the measurements of width, height, and length of the vertebral bodies from C5-C6 of all specimens. The prosthesis was developed using the Rhinoceros 3D® and SolidWorks® programs, and 3D prototyping was carried out to define the best design. The developed prosthesis consisted of two independent parts that are fixed to the cranial and caudal vertebral bodies, in the intervertebral space, and fitted together by metal-to-metal surfaces capable of moving in the lateral, ventral, and dorsal directions. Each part of the prosthesis is angled in two portions: vertically, in the intervertebral space, and horizontally, in contact with the ventral surface of the vertebral bodies, both of which are fixed by means of monocortical locking screws. The design of the developed prototype allowed a good fit in the intervertebral space between C4-C5, C5-C6, and C6-C7.


A artroplastia cervical com prótese de disco tem sido proposta como uma opção de tratamento para cães com Espondilomielopatia Cervical. O presente estudo teve como objetivo desenvolver uma nova prótese de disco intervertebral para cães. Dezesseis Unidades Funcionais de Coluna Vertebral (C5-C6) foram coletadas de cadáveres de cães com peso corporal variando entre 25 e 35 kg, e suas medidas vertebrais foram usadas para projetar um disco intervertebral protético. O dimensionamento da prótese foi realizado com base nas médias das mensurações da largura, altura e comprimento dos corpos vertebrais de C5-C6 de todos os espécimes. A prótese foi desenvolvida nos programas Rhinoceros 3D® e SolidWorks® e utilizou-se prototipagem em 3D para a definição do melhor design. A prótese desenvolvida é formada por duas partes independentes que se fixam às espífises dos corpos vertebrais cranial e caudalmente ao espaço intervertebral, e se encaixam entre si por superfícies de metal-metal com capacidade de movimentação nas direções lateral, ventral e dorsal. Cada parte da prótese é angulada em duas porções: a vertical, que fica no espaço intervertebral, e a horizontal, que fica em contato com a superfície ventral dos corpos vertebrais, ambas as quais são fixadas por meio de parafusos bloqueados monocorticais. O design do protótipo desenvolvido permitiu bom encaixe no espaço intervertebral entre C4-C5, C5-C6 e C6-C7.


Assuntos
Animais , Cães , Artroplastia/veterinária , Próteses e Implantes/veterinária , Doenças da Coluna Vertebral/veterinária , Doenças do Cão
6.
Ciênc. Anim. (Impr.) ; 33(1): 79-85, jan.-mar. 2023. tab
Artigo em Português | VETINDEX | ID: biblio-1434512

Resumo

O objetivo deste estudo retrospectivo foi identificar a ocorrência de fraturas apendiculares em cães e gatos, os métodos de tratamento e os resultados obtidos com os mesmos, no Hospital Veterinário (HV) da Universidade Regional do Noroeste do Estado do Rio Grande do Sul (Unijuí), no município de Ijuí - RS, no período de abril de 2013 a abril de 2022. De um total de 370 procedimentos cirúrgicos para tratamento de fraturas do esqueleto apendicular, 117 foram em fêmur (31,6%), 77 em tíbia e fíbula (20,8%), 62 em rádio e ulna (16,8%), 49 em úmero (13,2%), 45 em pelve (12,2%), 7 em metatarso e metacarpo (1,9%), 7 em tarso e carpo (1,9%), 4 em escápula (1,1%) e 2 em falanges (0,5%). O número de procedimentos foi superior ao número de animais, pois alguns apresentavam mais de uma fratura em diferentes ossos. Entre os 329 animais reportados neste estudo, concluiu-se que a principal causa de fraturas em cães e gatos foi atropelamento, sendo os filhotes os mais acometidos e as fraturas femorais as mais frequentes. Os fixadores esqueléticos externos destacaram-se como o método mais utilizado e o desfecho das osteossínteses foi satisfatório, sendo que a maior casuística correspondeu a fraturas cicatrizadas.


This retrospective study aimed to identify the occurrence of appendicular fractures in dogs and cats, treatment methods, and results obtained with them, at the Veterinary Hospital (VH) of the Regional University of the Northwest of the State of Rio Grande do Sul (Unijuí), in the city of Ijuí/RS, from April 2013 to April 2022. A total of 370 surgical procedures for the treatment of fractures of the appendicular skeleton was performed: 117 were in the fêmur (31,6%), 77 in the tíbia and fíbula (20,8%), 62 in the radius and ulna (16,8%), 49 in the humerus (13,2%), 45 in pélvis (12,2%), 7 in metatarsus and metacarpus (1,9%), 7 in tarsus and carpus (1,9%), 4 in the scapula (1,1%), and 2 in phalanges (0,5%). The number of procedures was higher than the number of animals, as some had more than one fracture in different bones. Among the 329 animals reported in this study, it was concluded that the main cause of fractures in dogs and cats was being run over, puppies were the most affected, and femoral fractures were the most frequent. External skeletal fixators stood out as the most used method and the outcome of osteosynthesis was satisfactory, with the largest number of cases corresponding to healed fractures.


Assuntos
Animais , Gatos , Cães , Próteses e Implantes/veterinária , Doenças do Gato , Doenças do Cão , Fraturas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária
7.
Arq. bras. med. vet. zootec. (Online) ; 75(1): 107-112, 2023. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1416599

Resumo

The use of endo-exo prosthesis is an alternative to improve the quality of life of amputees, allowing correct distribution of body weight, reducing skin problems and pain related to the implant, and reducing lameness. The aim of this paper is to report the use of a fixed bilateral endo-exo femur prostheses in a cat with amputation prior to treatment. The endoprostheses were made with titanium and the exoprostheses were made with 3D printing technology. A longitudinal craniolateral surgical approach was used and the skin incision was made over the knee-joint, then fascia lata incision, followed by biceps femoris and vastus lateralis muscles retraction, incision through the joint capsule to expose the tibiofemoral joint, disarticulation, and tibia and fibula removal. Afterwards, a femoral leveling osteotomy and insertion of the implant in the medullary canal were performed, being attached in the cis and trans cortical bone. The patient was evaluated in the immediate post-operative and periodically thereafter, showing satisfactory results, without macroscopic signs of rejection, wound dehiscence or infection, fracture, or injury of limbs, and presented adapted walking. Furthermore, it was observed the return to common behaviors for the species.


O uso de endoexoprótese é uma alternativa para melhoria na qualidade de vida de pacientes amputados, permitindo distribuição correta do peso corporal, redução de problemas de pele e dor ligadas ao implante e redução da claudicação. Este trabalho objetivou relatar a utilização de endoexoprótese bilateral fixa em fêmur em felino com amputação prévia ao atendimento. Foram modeladas endopróteses em titânio e exopróteses projetadas e impressas em 3D. O acesso cirúrgico, em ambos os membros, foi realizado por incisão craniolateral transarticular da pele, incisão da fáscia lata, rebatimento dos músculos bíceps femoral e vasto lateral, incisão da cápsula articular para exposição da articulação femorotibial, desarticulação e remoção cirúrgica da tibia e da fibula. Em seguida, realizou-se osteotomia niveladora femoral e inserção do implante no canal medular, sendo esse fixo nas corticais cis e trans. O paciente foi avaliado no pós-cirúrgico imediato e posteriormente de forma periódica, demonstrando resultados satisfatórios, sem sinais macroscópicos de rejeição, deiscência ou infecção da ferida cirúrgica, fratura ou lesão de membros, e apresentava deambulação adaptada. Além disso, foi observado o retorno de comportamentos comuns da espécie.


Assuntos
Animais , Gatos , Membros Artificiais/veterinária , Procedimentos Ortopédicos/veterinária , Fêmur/transplante , Impressão Tridimensional , Caminhada
8.
Clín. Vet. (São Paulo, Ed. Port.) ; 28(164): 44-55, mai.-jun. 2023.
Artigo em Português | VETINDEX | ID: biblio-1434776

Resumo

Um lobo-guará (Chrysocyon brachyurus) macho com 15 anos de idade apresentou dificuldade ao se levantar e deitar, relutância ao caminhar e aspecto arqueado da coluna vertebral. Após contenção química, o paciente foi examinado e submetido a exames radiográficos e colheita de material biológico para análises laboratoriais. Os resultados dos exames apontaram um animal saudável, porém visualizaram-se espondiloses em coluna vertebral na região cervical e torácica. Foi iniciado protocolo para controle de dor, inflamação e uso de regenerador articular, a fim de estabilizar o quadro do paciente. Novo manejo foi agendado para implante de filamentos de ouro em pontos de acupuntura. Após essa terapia, o paciente foi acompanhado pela equipe veterinária, e alguns dias após o tratamento houve melhora do quadro clínico o animal deixou de apresentar dificuldade para caminhar, deitar, levantar e ficar em estação. O paciente retornou ao recinto, dividindo o local com a fêmea, e até o momento está assintomático.(AU)


A 15-year-old male maned wolf (Chrysocyon brachyurus) showed difficulty getting up and lying down, reluctance to walk and an arched aspect of the spine. After chemical containment, the patient underwent physical examination and was submitted to radiographic examens and collection of biological material for laboratory analysis. The test results indicated a healthy animal, but spondylosis was seen in the cervical and thoracic spine. A protocol was started to pain control, inflammation, and use of condroprotective to stabilize the patient's condition. A new management was scheduled for the implantation of gold filaments in acupuncture points. After this therapy, the patient was followed up by the veterinary team, and days after the treatment, there was an improvement in the clinical condition- the animal had no more difficulty walking, lying down, getting up and standing still. The patient returned to the enclosure, sharing the place with the female, and so far, the clinical signs presented are absent and/or reduced.(AU)


Un aguará guazú (Chrysocyon brachyurus) macho de 15 años mostró dificultad para levantarse y acostarse, renuencia a caminar y un aspecto arqueado de la columna vertebral. Después de la contención química, el paciente fue examinado y sometido a exámenes radiográficos y recolección de material biológico para análisis de laboratorio. Los resultados de la prueba indicaron un animal sano, pero se observó espondilosis en la columna cervical y torácica. Se inició protocolo de control del dolor, inflamación y uso de protectores articulares, con el fin de estabilizar el estado del paciente. Con el objetivo de brindar una mejor calidad de vida, ya que se trata de un animal salvaje, incapaz de realizar ordinariamente terapias invasivas, se implantaron filamentos de oro en puntos de acupuntura. Posteriormente a esta terapia, el paciente fue acompañado por el equipo veterinario, y dias después del tratamiento hubo una mejoría en el estado clínico - el animal no tuvo dificultad para caminar, acostarse, levantarse y estar de pie. El paciente regresó al recinto, compartiendo el lugar con una hembra, y hasta el momento los signos clínicos anteriormente presentados están ausentes y/o reducidos.(AU)


Assuntos
Animais , Masculino , Terapia por Acupuntura/veterinária , Canidae , Espondilose/veterinária
9.
Acta sci. vet. (Impr.) ; 51(supl.1): Pub. 865, 2023. ilus, tab, graf
Artigo em Português | VETINDEX | ID: biblio-1434678

Resumo

Background: Ischemic neuromyopathy is the most common reason for amputation in cats. In veterinary medicine, the use of prosthetic limbs is not widespread; therefore, in most cases total limb amputation is indicated. However, hyperbaric oxygen therapy (HBOT) is an alternative with several benefits for the treatment of vascular disorders with reperfusion, ischemia, and infection. Therefore, this study aimed to report the positive effects of HBOT on the treatment of ischemic neuromyopathy secondary to arterial thromboembolism on the patient's clinical improvement, and on the preparation of the patient for insertion of an osseointegrated prosthesis. Case: A 6-month-old mixed-breed kitten returned for treatment after undergoing surgery seven days earlier for reduction of traumatic diaphragmatic hernia, during which it suffered a cardiorespiratory arrest. The patient presented with acute pelvic limb paralysis with 24-h evolution, absent femoral pulse, plantar cushions and dorsal part of the limbs cold and pale. After supportive therapy and diagnosis of aortic thromboembolism by arterial Doppler, the patient started adjunctive treatment with HBOT from the first day of hospitalization. Sessions took place in an exclusive hyperbaric chamber for animals and lasted 60 min at a pressure of 2.5 absolute atmospheres and 100% oxygen, initially every 12 h. However, during the first 5 days of hospitalization, the distal region of both pelvic limbs began to show tissue devitalization and edema, and hematologic parameters showed changes on the 7th day. The right pelvic limb (RPL) showed more involvement of superficial tissues, extending to the tarsometatarsal joint region. After 8 days of hospitalization, the devitalized tissue was debrided. The RPL had an extensive devitalized area with exposed bone in the phalanges and necrosis in the pads. The left pelvic limb (LPL) suffered minor complications, with involvement of the phalangeal region. After 12 days, with HBOT every 48 h, exuberant granulation tissue was observed. After 17 days, the patient was discharged, and HBOT sessions were performed weekly. Gangrene of the midfoot and lack of proprioception were observed in RPL, while LPL showed bone divulsion of the 1st, 3rd, and 4th phalanges. Because of the poor prognosis for limb viability, the RPL was partially amputated, and a self-threaded intraosseous prosthesis was inserted. Discussion: The cardiorespiratory arrest that occurred during the surgical procedure to reduce the diaphragmatic hernia without thromboprophylaxis may have contributed to the peripheral ischemia. HBOT was proposed for the adjuvant treatment of ischemic injury because it is especially indicated for cases of ischemia-reperfusion injury. The main hematological parameters were evaluated at an average interval of 7 days. While the platelet count and hematocrit increased, the leukocytosis decreased. This demonstrates the benefit of oxygen therapy in the reported patient. The use of HBOT in orthopedic injuries is known to result mainly in stimulation of osteoblasts, promoting osseointegration of the prosthesis. We conclude that the adjuvant treatment with HBOT helped to preserve a large segment of both pelvic limbs, prevent the progression of necrosis, and provide a healthy bed for fixation of an osseointegrated prosthesis in the RPL, resulting in clinical improvement of the patient.


Assuntos
Animais , Feminino , Gatos , Tromboembolia/terapia , Tromboembolia/veterinária , Prótese Ancorada no Osso/veterinária , Oxigenoterapia Hiperbárica/veterinária
10.
Vet. Not. (Online) ; 28(1): 1-7, abr. 2022. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1400928

Resumo

Testudines are members of the Reptilia class, they are ectothermic and differ from other reptiles by the presence of the shell, which covers most of their bodies. Shell fractures are common in these animals and can occur due to several factors, mainly trauma. This paper aims to report the use of prosthesis in a red-footed tortoise (Chelonoidis carbonarius). An adult female weighing 2.45 kg was sent to the Wild Animal Sector of Veterinary Hospital of University of Brasilia. The specimen presented carapace fracture caused by compress of garbage truck. Even after healing the lesion, there was persistent communication between the coelomic cavity and the environment, which caused recurrent pneumonia. After stabilization of the patient and treatment of infections, an adhesive cover was placed to isolate the coelomic cavity, which was changed periodically. Moreover, it was decided to make a prosthesis with acrylic resin, since it was not feasible to perform the repair by conventional methods. The method was satisfactory in the sealing of the carapace and the animal was monitored for a month without showing signs of pneumonia or any other complications.(AU)


Os testudines pertencem à classe Reptilia, são ectotérmicos e se diferem dos demais répteis pela presença do casco, que envolve a maior parte de seus corpos. Fraturas nesse arcabouço ósseo são comuns e podem ocorrer devido a diversos fatores, principalmente traumas. O presente trabalho tem como objetivo relatar um caso de colocação de prótese em casco de jabuti-piranga (Chelonoidis carbonarius). Um exemplar adulto, fêmea, de 2,45 kg, foi encaminhado ao Setor de Animais Silvestres do Hospital Veterinário da Universidade de Brasília. O espécime apresentava fratura de carapaça provocada por prensas compactadoras de um caminhão de coleta de lixo domiciliar. Mesmo após a cicatrização da lesão, houve persistência de uma comunicação da cavidade celomática com o meio externo, o que ocasionava quadros de pneumonia recorrentes. Após estabilização do paciente e tratamento das infecções, foi colocada uma cobertura com esparadrapo para isolar a cavidade celomática, que era trocada periodicamente. Posteriormente, decidiu-se pela confecção de uma prótese feita de resina acrílica, visto que não era viável realizar o reparo por técnicas convencionais. O método se mostrou satisfatório na vedação da carapaça e o animal foi acompanhado durante um mês sem demonstrar indícios de pneumonia ou qualquer complicação.(AU)


Assuntos
Animais , Feminino , Próteses e Implantes/veterinária , Tartarugas/lesões , Exoesqueleto/cirurgia
11.
Acta sci. vet. (Impr.) ; 50: Pub.1851-2022. ilus, graf
Artigo em Inglês | VETINDEX | ID: biblio-1458526

Resumo

Background: Orthopedic implants are commonly used for different types of surgical procedures to gain optimal functionand to provide stability to both bones and tendon structures. When inserting these implants, the characteristics of the material are important for surgical success, and the ideal implant must be biocompatible and nonallergenic. However, whenmolding an implant to the bone structure, its resistance can change significantly. Implants can be temporary or permanentin the body, and metal possesses properties that make it acceptable for bone repair. In biomedical implants, 2 types aremost common, commercially pure (CP)-Ti and Ti-6A1-4V. They both provide stable fixation and low risk of loosening.Implants made with the same material and composition can perform differently if the material has been altered by processing techniques for different scenarios. Stress, strain and elastic modulus are the primary metrics used in the description ofimplant materials. They can be calculated based on mechanical tests of specimens with defined geometry, most commonlytensile, bending and torsional tests. In order to better evaluate those changes, we compared the mechanical characteristicsof titanium bone plates, before and after they were molded to the bone, to verify and quantify the loss of stiffness andresistance after molding the plate.Materials, Methods & Results: The study was prospective. Orthopedic implant made of commercially pure titanium (CPTi) were divided into 2 groups, one group without plate molding and the other with plate molding to a dog femora bone.Thirty-six plates of different sizes (5.0, 6.5, 8.0, 9.0, 10.0- and 11.0-mm diameter) were divided into 6 groups containing6 plates of each size and submitted to the 4-point flexion test of resistance, using a piece of dog femur (weights of 5, 10,15, 20 and 25 kg) as the bone in which the...


Assuntos
Animais , Cães , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/veterinária , Materiais Biocompatíveis , Placas Ósseas/veterinária , Titânio/análise , Próteses e Implantes/veterinária
12.
Acta sci. vet. (Online) ; 50: Pub. 1851, Jan. 19, 2022. ilus, graf
Artigo em Inglês | VETINDEX | ID: vti-765215

Resumo

Background: Orthopedic implants are commonly used for different types of surgical procedures to gain optimal functionand to provide stability to both bones and tendon structures. When inserting these implants, the characteristics of the material are important for surgical success, and the ideal implant must be biocompatible and nonallergenic. However, whenmolding an implant to the bone structure, its resistance can change significantly. Implants can be temporary or permanentin the body, and metal possesses properties that make it acceptable for bone repair. In biomedical implants, 2 types aremost common, commercially pure (CP)-Ti and Ti-6A1-4V. They both provide stable fixation and low risk of loosening.Implants made with the same material and composition can perform differently if the material has been altered by processing techniques for different scenarios. Stress, strain and elastic modulus are the primary metrics used in the description ofimplant materials. They can be calculated based on mechanical tests of specimens with defined geometry, most commonlytensile, bending and torsional tests. In order to better evaluate those changes, we compared the mechanical characteristicsof titanium bone plates, before and after they were molded to the bone, to verify and quantify the loss of stiffness andresistance after molding the plate.Materials, Methods & Results: The study was prospective. Orthopedic implant made of commercially pure titanium (CPTi) were divided into 2 groups, one group without plate molding and the other with plate molding to a dog femora bone.Thirty-six plates of different sizes (5.0, 6.5, 8.0, 9.0, 10.0- and 11.0-mm diameter) were divided into 6 groups containing6 plates of each size and submitted to the 4-point flexion test of resistance, using a piece of dog femur (weights of 5, 10,15, 20 and 25 kg) as the bone in which the...(AU)


Assuntos
Animais , Cães , Titânio/análise , Placas Ósseas/veterinária , Materiais Biocompatíveis , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/veterinária , Próteses e Implantes/veterinária
13.
Acta cir. bras ; 37(2): e370201, 2022. tab, graf, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1374072

Resumo

Purpose: To evaluate fibrosis formation and number of macrophages in capsules formed around textured implants without and with mesh coverage. Methods: Fibrosis was analyzed through transforming growth factor-beta 1 (TGF-ß1) immunomarker expression and the number of macrophages through CD68 percentage of cells in magnified field. Sixty female Wistar rats were distributed into two groups of 30 rats (unmeshed and meshed). Each group was then subdivided into two subgroups for postoperative evaluation after 30 and 90 days. The p value was adjusted by Bonferroni lower than 0.012. Results: No difference was observed in fibrosis between meshed and unmeshed groups (30 days p = 0.436; 90 days p = 0.079) and from 30 to 90 days in the unmeshed group (p = 0.426). The meshed group showed higher fibrosis on the 90th day (p = 0.001). The number of macrophages was similar between groups without and with mesh coverage (30 days p = 0.218; 90 days p = 0.044), and similar between subgroups 30 and 90 days (unmeshed p = 0.085; meshed p = 0.059). Conclusions: In the meshed group, fibrosis formation was higher at 90 days and the mesh-covered implants produced capsules similar to microtextured ones when analyzing macrophages. Due to these characteristics, mesh coating did not seem to significantly affect the local fibrosis formation.


Assuntos
Animais , Feminino , Ratos , Telas Cirúrgicas/veterinária , Fibrose/veterinária , Antígenos CD/análise , Implantes de Mama/veterinária , Implante Mamário/instrumentação , Fator de Crescimento Transformador beta1/análise , Ratos Wistar/cirurgia
14.
Ciênc. rural (Online) ; 52(9): e20210310, 2022. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1360358

Resumo

A six-month-old male Brazilian Terrier with persistent cough and dyspnea was diagnosed with intrathoracic tracheal collapse and pneumonia after chest radiographics. The medical treatment was performed, and an extraluminal nitinol prosthesis was placed through thoracic access. The dog did not presented recurrence of dyspnea or pneumonia for four years after the surgical procedure. Placement of the extraluminal prosthesis with the thoracic approach effectively stabilized intrathoracic tracheal collapse without causing any structural damage in the thoracic region. Therefore, this is the first report of a successful use of this prosthesis with an intercostal approach in dogs for intrathoracic trachea collapse.


Um cão macho, da raça Terrier Brasileiro de seis meses de idade, com dispnéia e tosse persistente foi diagnosticado com colapso traqueal intratorácico e pneumonia após estudo radiográfico de tórax. Foi instituído tratamento médico e realizada toracotomia para a implantação de prótese traqueal extraluminal de nitinol. O animal não manifestou dispneia ou pneumonia durante os quatro anos posteriores ao procedimento. A implantação da prótese extraluminal através da toracotomia foi eficaz para o tratamento do colapso traqueal intratorácico, sem provocar danos estruturais na região torácica. Desta forma, este é primeiro relato da utilização bem-sucedida deste tipo de prótese, a partir da abordagem intercostal, no tratamento de cães com colapso traqueal intratorácico.


Assuntos
Animais , Masculino , Cães , Próteses e Implantes/veterinária , Traqueia/cirurgia , Toracotomia/veterinária , Doenças do Cão/diagnóstico por imagem , Cães
15.
Rev. bras. ciênc. vet ; 29(1): 13-18, jan./mar. 2022. il.
Artigo em Português | LILACS, VETINDEX | ID: biblio-1393188

Resumo

As fístulas oronosais adquiridas são defeitos que permitem a comunicação anormal entre as cavidades oral e nasal. Inúmeras causas podem ser atribuídas à etiologia de tal defeito. O presente trabalho visa relatar o caso de um cão com fístula oronasal adquirida que foi submetido à reconstrução cirúrgica do palato com o uso de malha de polipropileno e prótese acrílica. Após estabilização do quadro clínico e remoção manual das larvas, o paciente foi encaminhado para o desbridamento cirúrgico das lesões orais e correção do defeito no palato. A palatoplastia foi realizada com o uso da malha e resina de polimetilmetacrilato autopolimerizável. A malha foi suturada sobre o defeito palatino com pontos simples separados e fio náilon 3-0 nas extremidades da ferida. Em seguida, a resina foi preparada e, ao atingir consistência adequada, foi aplicada e modelada sobre o a malha de polipropileno com o auxílio de um descolador de Molt, sendo também suturada nas bordas da fístula com pontos simples separados e fio náilon 3-0. No mesmo tempo cirúrgico foi inserida uma sonda esofágica para alimentação enteral. Devido complicações cirúrgicas no pós operatório, o paciente foi submetido a mais duas intervenções cirúrgicas para desfecho satisfatório do tratamento. Conclui-se que associação entre a tela de polipropileno e a prótese acrílica foi uma alternativa exequível para a palatoplastia em cão.


Acquired oronosal fistulae are abnormal communication between the oral and nasal cavities. A oronasal fistula can be the result of different causes, like oral myiasis. The objetctive of these paper is to report the case of a dog with acquired oronasal fistula that underwent surgical reconstruction of the palate using polypropylene mesh and acrylic prosthesis. After stabilization of the patient ́s clinical condition and mecanic removal of the larvae, the dog was referred for surgical debridement of the oral lesions and correction of the defect in the palate. Palatoplasty was performed using a mesh and polymethylmethacrylate resin. The mesh was sutured over the palatal defect with separate simple suture and 3-0 naylon thread at the ends of the wound. Then, the resin was prepared and, upon reaching adequate consistency, it was applied and shaped over the polypropylene mesh with Molt peeler. It was also sutured on the edges of the fistula with separate simple suture and 3-0 nylon suture. At the same surgical time, an esophageal tube was inserted for enteral feeding. Due to complications, the dog underwent two more surgical interventions for a satisfactory treatment outcome. It is concluded that the association between the polypropylene mesh and the acrylic prosthesis was a practical alternative for palatoplasty in dogs after oral myiasis.


Assuntos
Animais , Cães , Obturadores Palatinos/veterinária , Palato/cirurgia , Polipropilenos , Próteses e Implantes/veterinária , Fístula Bucal/veterinária , Procedimentos de Cirurgia Plástica/veterinária , Cães/cirurgia , Miíase/veterinária
16.
Ciênc. rural (Online) ; 52(9): e20210498, 2022. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1369624

Resumo

The surgical clinic of wild animals has increased in routine veterinary, where fractures by traumas are of frequent occurrence. This study determined the surgical accesses for osteosynthesis of the diaphyses of the humerus, radius and ulna of common sloth (Bradypus variegatus). Seven cadavers of B. variegatus were used for determination of the muscles of the thoracic limb, as well as the most important vessels and nerves, and better bone area for fixation of internal implants. The structural conformation of the radius and ulna in Bradypus variegatus were like those described in the literature for domestic animals but the humerus presented differences in the distal extremity because it was flattened. The musculature of Bradypus variegatus showed similarities with domestic animals. Due the different conformation of the humerus the surgical access to this bone can be performed by lateral approach, from the incision of M. triceps brachii lateral head, for fixation of the implant on the lateral side of the bone. Surgical access to the radius shaft can be performed by craniolateral approach, by incising the muscular fascia and separation of the cranially M. common digital extensor, and lateral digital extensor caudally. In ulna, a caudal access to the bone can be performed followed by release of the insertion m. flexor carpoulnar for placement of the internal implant on the lateral bone face.


A clínica cirúrgica de animais silvestres tem se intensificado na rotina veterinária, onde fraturas por traumas são frequentes. O objetivo deste estudo foi a determinação de acessos cirúrgicos para osteossíntese das diáfises do úmero, rádio e ulna de preguiça-comum (Bradypus variegatus). Sete cadáveres de B. variegatus foram utilizados para determinação dos músculos do membro torácico, bem como dos vasos e nervos mais importantes, e melhor área óssea para fixação de implantes internos. A conformação estrutural do rádio e da ulna em B. variegatus eram similares às descritas na literatura para animais domésticos, o úmero apresentou diferenças na extremidade distal pois apresentou-se achatado. A musculatura de B. variegatus mostrou semelhanças com os animais domésticos. Devido à diferente conformação do úmero o acesso cirúrgico a este osso pode ser realizado por abordagem lateral, a partir da incisão do M. tríceps braquial cabeça lateral, para fixação do implante na face lateral do osso. O acesso cirúrgico à diáfise do rádio pode ser realizado por abordagem craniolateral, por incisão da fáscia muscular e separação cranialmente do M. extensor digital comum e extensor digital lateral caudalmente. Na ulna, pode-se realizar um acesso caudal ao osso seguido de liberação da inserção do M. flexor carpoulnar para colocação do implante interno na face lateral do osso.


Assuntos
Animais , Fraturas do Rádio/veterinária , Bichos-Preguiça/anatomia & histologia , Fraturas da Ulna/veterinária , Fixação Interna de Fraturas/veterinária , Fraturas do Úmero/veterinária
17.
Acta cir. bras ; 37(5): e370502, 2022. graf, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1393757

Resumo

Purpose: To identify an optimal self-expandable metallic stent (SEMS) and verify whether a mechanically superior SEMS would result in better clinical outcomes in the treatment of tracheal collapse. Methods: We selected three SEMS (n = 8 each), including an S-type stent with a wire diameter of 0.006 inches (S6) and two D-type stents with wire diameters of 0.006 (D6) and 0.007 inches (D7). Twenty-four New Zealand White rabbits were divided into three equal groups. After the stents were deployed, the clinical signs were recorded daily, and radiographic examinations were performed monthly. All rabbits were euthanized after three months. Results: Two rabbits with S6 stents and one rabbit with a D7 stent died within three months because of stent migration or pneumonia. All rabbits with D6 stents survived for three months. On histological examination, the D6 group had the lowest inflammation score. Conclusions: Both clinically and histopathologically, the results with D-type stents with a wire diameter of 0.006 inches were superior to those of the other groups (p = 0.001). The use of an optimal intraluminal stent may improve the long-term clinical outcomes in the treatment of tracheal collapse in dogs.


Assuntos
Animais , Coelhos , Coelhos , Doenças da Traqueia/terapia , Stents
18.
Arq. bras. med. vet. zootec. (Online) ; 74(5): 869-880, Sep.-Oct. 2022. graf, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1403411

Resumo

The objective of this study was to assess healing induction of free skin grafts following transposition of omental flap through a subcutaneous tunnel to the recipient bed. Macroscopic and microscopic evaluations were performed. Nineteen piglets were used. Two surgical wounds were created of each subject. The graft removed from the left side (LS) was placed on the right side (RS) without the omental flap in the graft-bed (control group-CG). On the LS, an omental flap was placed between the graft removed from the RS and the recipient bed (omentum group-OG). Macroscopic evaluations showed edema, which gradually decreased on both groups. Suture dehiscence was highest at day 10 compared to other days in both groups. The CG had a higher incidence of unvitalized tissue compared to OG, although no difference was found among days of postoperative evaluation. The presence of unvitalized tissue was seen on 32% on OG and 53% on CG. Microscopic evaluations revealed higher collagenization, reepithelization, keratinization and less swelling in the OG compared to CG. In conclusion, mesh skin grafts evolved satisfactorily in swine even in newly created bedding without granulation tissue, but with appropriate vascularization. The omentum flap provided better macroscopic and microscopic outcomes regarding graft integration.


O objetivo deste estudo foi verificar a indução da cicatrização de enxertos cutâneos em malha após a utilização de flap de omento transposto através de túnel no subcutâneo até o leito receptor. Avaliações macroscópica e microscópica foram realizadas. Foram utilizados 19 suínos. Duas feridas cirúrgicas foram criadas em cada animal. O enxerto removido do lado esquerdo (LE) foi fixado do lado direito (LD), sem a presença do flap de omento entre o enxerto e o leito receptor (grupo controle - GC). No LE, foi fixado um flap de omento entre o enxerto cutâneo removido do LD e o leito receptor (grupo omento - GO). As avaliações macroscópicas mostraram que o edema diminuiu gradativamente em ambos os grupos. A deiscência foi maior no dia 10 em comparação aos demais dias, em ambos os grupos, entre os diferentes dias de avaliação. Foi verificada a presença de tecido desvitalizado em 32% do GO e em 53% no GC. Foi observada, na avaliação microscópica, maior colagenização, reepitelização, queratinização e menor edema no GO, quando comparado ao GC. Concluiu-se, com este estudo, que enxertos cutâneos em malha evoluíram satisfatoriamente em suínos, mesmo em leito receptor recém-criado e sem presença de tecido de granulação, desde que vascularizado, e que o flap de omento propiciou melhores resultados macro e microscópicos relativos à integração do enxerto.


Assuntos
Animais , Omento/transplante , Suínos/lesões , Neovascularização Fisiológica , Retalhos de Tecido Biológico/veterinária , Procedimentos de Cirurgia Plástica/veterinária
19.
Ciênc. anim. bras. (Impr.) ; 23: e-72441P, 2022. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1404226

Resumo

The aim of this study was to verify the efficiency and ovulation time after the administration of different inducers for synchronization of ovulation in beef cows. One hundred and eight non-lactating cows were distributed into the control group (CG; untreated; n=28), estradiol benzoate (EB) group (EBG; n=28); 17 beta-estradiol (17ßE) group (17ßEG; n=28), and deslorelin (DES) group (DESG; n=24). On day minus 11 (D-11) of the protocol, the CG underwent application of cloprostenol and ultrasound examination (US); on D0, progesterone (P4) was inserted plus EB; on D7, cloprostenol was applied; on D9, P4 was removed and cloprostenol plus 400 IU of equine chorionic gonadotropin (eCG) was injected. The EBG was subjected to treatment identical to that of the CG, except on D10, when the cows received EB. The 17ßE was subjected to the same protocol used in the CG except for the administration of 17ßE on D10. And, the DESG was subjected to the same treatment as the CG, except on D10, when the group received DES acetate. Twelve hours after the administration of EB, 17ßE and DES, ovarian US were performed every 6 hours. The preovulatory follicle (POF) diameters measured before ovulation were 19.5; 14.7; 18.7 and 19.8 mm respectively for CG, EBG, 17ßEG and DESG; and the time intervals between inducer application and ovulation were 20.2; 18.9; 21.0 and 22.5 hours respectively. In conclusion, all ovulation inducers were efficient in promoting ovulation; the inducers caused ovulation between 18.9 and 22.5 hours; EB promoted ovulation in a shorter time (P<0.05); 17ßE and DES showed greater variation in application/ovulation time between groups.


O objetivo do estudo foi verificar a eficiência e a ovulação após a administração de diferentes indutores para a sincronização da ovulação em vacas de corte. Cento e oito vacas não-lactantes foram distribuídas em grupo controle (GC; não tratadas; n=28); grupo benzoato de estradiol (BE) (GBE; n=28); grupo 17 beta-estradiol (17ßE) (G17ßE; n=28) e grupo deslorelina (DES) (GDES; n=24). No dia menos 11 (D-11) do protocolo, o GC recebeu cloprostenol e exame ultrassonográfico (US); ao D0, dispositivo de progesterona (P4) foi inserido mais BE; ao D7, cloprostenol foi aplicado; ao D9, a P4 foi removida e cloprostenol mais 400 UI de gonadotrofina coriônica equina (eCG) foi injetada. O GBE foi submetido a tratamento idêntico ao do GC, exceto ao D10, quando as vacas receberam BE. o G17ßE foi submetido ao mesmo protocolo usado no CG exceto pela administração de 17ßE ao D10. E, o GDES foi submetido ao mesmo tratamento que o CG, exceto ao D10, quando o grupo recebeu o acetato de DES. Doze horas após a administração de BE, 17ßE e DES, US ovarianos foram realizados a cada 6 horas. O diâmetro do folículo pré-ovulatório (FPO) medido antes da ovulação foi de 19,5; 14,7; 18,7 e 19,8 mm respectivamente para GC, GBE, G17ßE e GDES; e o intervalo de tempo entre a aplicação do indutor e ovulação foi 20,2; 18,9; 21;0 e 22,5 horas respectivamente. Em conclusão, todos os indutores da ovulação foram eficientes em promover a ovulação; os indutores acarretaram ovulação entre 18,9 e 22,5 horas; o BE promoveu a ovulação em menor espaço de tempo (P<0,05); 17ßE e DES demonstraram maior variação em aplicação/tempo de ovulação entre os grupos.


Assuntos
Animais , Feminino , Bovinos , Indução da Ovulação/veterinária , Bovinos , Estradiol , Sincronização do Estro , Remoção de Dispositivo/veterinária
20.
Rev. bras. reprod. anim ; 46(4): 393-395, out.-dez. 2022.
Artigo em Inglês | VETINDEX | ID: biblio-1415134

Resumo

A superpopulação de felinos e caninos é um problema global que ainda não encontrou uma solução definitiva. Existem várias estratégias que procuram encontrar uma resposta para este problema. Atualmente, a castração cirúrgica é o único método de controle permanente da reprodução. No entanto, existem vários relatos sobre o uso de anticoncepcionais não cirúrgicos para cães e gatos para controle da reprodução a longo prazo. Os análogos de GnRH suprimem a reprodução por muito tempo e seu efeito é reversível, podendo ser usados nos casos em que a castração cirúrgica não pode ser realizada ou até que possa ser realizada. A deslorelina é um agonista de GnRH desenvolvido como implante subcutâneo para uso em cães, embora também tenha sido usado em gatos e espécies não domésticas. O objetivo deste relato foi resumir o conhecimento atual sobre o agonista de GnRH deslorelina como um contraceptivo não cirúrgico para cães e gatos.(AU)


La sobrepoblación felina y canina es un problema mundial que aún no ha encontrado una solución definitiva. Existen diversas estrategias, que buscan encontrar una respuesta a esta problemática. Actualmente, la castración quirúrgica es el único método de control permanente de la reproducción. Sin embargo, existen múltiples reportes sobre la utilización de contraceptivos no quirúrgicos para perros y gatos para el control a largo plazo de la reproducción. Los análogos de GnRH, suprimen la reproducción en forma prolongada y su efecto es reversible, por lo que pueden ser utilizados en casos donde la castración quirúrgica no pueda ser realizada o hasta que la misma pueda llevarse a cabo. La deslorelina, es un agonista de GnRH desarrollado en forma de implante subcutáneo para su utilización en perros, aunque ha sido utilizada también en gatos y en especies no domésticas. El objetivo de este reporte fue resumir el conocimiento actual acerca del agonista de GnRH deslorelina como contraceptivo no quirúrgico para perros y gatos.(AU)


Assuntos
Animais , Gatos , Cães , Hormônio Liberador de Gonadotropina/administração & dosagem , Hormônio Liberador de Gonadotropina/análogos & derivados , Controle da População , Anticoncepcionais/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA